GENERAL
Do not use with water that is microbiologically unsafe
or of unknown quality without adequate disinfection before or after
the system.
Filter must be protected against freezing, which can
cause cracking of the filter and water leakage.
Because of the product’s limited service life and to
prevent costly repairs or possible water damage, we
strongly recommend that the bottom of all plastic
housings be replaced every five years for clear and ten
years for opaque. If the bottom of your housing has been
in use for longer than this period, it should be replaced
immediately. Date the bottom of any new or replacement
housing to indicate the next recommended replacement
date.
NOTE:
• Your water must be within required limits for satisfactory operation.
If not, your membrane life may be shortened and your warranty will
be voided (see Specifications on page 1).
• This reverse osmosis system will not protect against disease-
causing bacteria or remove naturally-occurring harmless bacteria.
• Install on cold water line only.
• Do not use wicking or sealer to t connections into the cap of the
filter. Teflon®tape is recommended.
• Make certain that installation complies with all state and local laws
and regulations.
• The replacement cartridges and reverse osmosis membrane
included with this system have limited service lives. Changes in
taste, odor, and color of the water being filtered indicate that the
cartridge should be replaced (see Replacing the Pre- and Post-
Filters on page 8, and Replacing the Membrane, on page 9).
• After prolonged periods of non-use (such as during a vacation) it is
recommended that the system be flushed for 5 minutes before it is
used.
• A drinking water cartridge may contain carbon nes (very ne
black powder). After installation, flush the cartridge for 5 minutes to
remove the carbon fines before using the water.
• It is recommended that you run the tap at least 20 seconds prior to
using water for drinking or cooking purposes.
• The contaminants or other substances removed or reduced by this
water treatment device are not necessarily present in your water.
RO MEMBRANE PRECAUTIONS
Chlorine will destroy the TFM-36 membrane. If you use
the RO-2500 with a chlorinated or periodically-chlorinated
water supply, it is ABSOLUTELY NECESSARY to use a
carbon pre-filter (included with the system). This carbon
pre-filter should be changed at least every 3 months to
avoid chlorine bypass. See Warranty for disclaimers and
limitations that apply to the TFM-36 membrane.
NOTE:
• To make sure no chlorine is present in the water that reaches the
membrane, you may want to use a chlorine test kit to check the
brine/reject water that flows from the membrane to the drain. No
chlorine should be detected.
• The TFM-36 membrane is resistant to naturally-occurring bacteria.
HOW REVERSE OSMOSIS WORKS
The RO-2500 Reverse Osmosis (RO) System uses a semi-permeable
membrane to reduce dissolved salts and minerals, improving the
taste and odor of your water. The RO membrane is made of layers of
micron-thin film wound around a hollow center core. Water molecules
can pass through the membrane, but dissolved salts and minerals are
rejected.
The RO-2500 Reverse Osmosis System features 4-stage filter action.
Your water supply is pre-ltered to reduce dirt and chlorine that may
foul the membrane. The RO membrane separates this pre-filtered
water into PRODUCT WATER and DRAIN or REJECT WATER. Incoming
water pressure forces the product water through the membrane
and into the storage tank. Dissolved solids and other contaminants
cannot pass through the membrane and are sent to the drain as reject
water. When you open the drinking water faucet, product water is
drawn from the storage tank through an activated carbon post-filter,
providing you with cleaner, great-tasting water.
For each gallon of water produced, several gallons are discharged
as reject water. The storage tank can hold up to 1.3 gallons (4.9 L) of
water at a time, for drinking and cooking needs. When used under
the Specifications on page 1 of the manual, your Reverse Osmosis
membranes should last 12-24 months.
BASIC INSTALLATION PROCEDURE GUIDELINES
• For standard, under-sink installation on 3/8-inch (10 mm) steel, brass,
or copper cold water line.
• Please read all instructions and precautions before installing and
using your RO-2500.
• Numbered diagrams correspond with numbered steps.
Precautions
2