* Timing Report:
Beside the event triggered could report message, the device also
support the timing unsolicited report of the status.
•Battery level report: Every 6 hours report once in default.
It could be changed by setting the configuration NO. 8.
•Low battery report: When the battery level is too low. (Lose
battery report when a power-on or PIR trigger.)
•LightSensor level report: Every 6 hours report once in default.
It could be changed by setting the configuration NO. 9.
•Temperature report: Every 6 hours report once in default.
It could be changed by setting the configuration NO. 10.
Notice: The configuration NO. 8 could be setting to zero to disable
the auto report. And the configuration NO. 11 could change the tick
interval, the default value is 30, if setting to 1, that means the
minimum auto report interval will be one minute.
Power Up Procedure
* Battery Power Check
When the device power up, the device will detect the power level of the
battery immediately. If the power level is too low, the LED will continue
flash about 5 seconds. Please change another new battery.
* Wake
When the device power on, the device will wake about 20 seconds. In
this duration, the controller can communicate with the device. Normally
the device is always sleeping to save the battery energy.
Security Network
The device support the security function. When the device included
with a security controller, the device will auto switch to the security
mode. In the security mode, the follow commands need using Security
CC wrapped to communicate, otherwise it will not response.
CO AND_CLASS_VERSION_V3
CO AND_CLASS_ ANUFACTURER_SPECIFIC_V2
CO AND_CLASS_DEVICE_RESET_LOCALLY
CO AND_CLASS_ASSOCIATION_V2
CO AND_CLASS_ASSOCIATION_GRP_INFO
CO AND_CLASS_POWERLEVEL
CO AND_CLASS_CONFIGURATION
CO AND_CLASS_NOTIFICATION_V8
CO AND_CLASS_FIR WARE_UPDATE_ D_V4
CO AND_CLASS_BATTERY
CO AND_CLASS_SENSOR_ ULTILEVEL_V11
CO AND_CLASS_WAKE_UP_V2
Operation Mode
There are two modes “Test” and “Normal”. “Test ode” is for the user
test the sensor function when installation.“Normal ode” is for the
normal operation.
Operation ode can be switched by pressing button or tamper key two
times. LED can indicate which mode it is. Lighting on one second
means entering test mode, flashing once means entering normal mode.
When the event triggered, normally the LED won't indicated, unless the
battery is in the low level, the LED will flash once. But in the “Test
ode” the LED also will light ON one second.
When the event triggered, the device will emit the signal to turn ON
the lighting equipment, those nodes are in the group 2. And delay a
while to turn OFF the lighting equipment. The delay time is setting by
the configuration NO. 7.
The PIR motion re-detected interval, in the “Test ode” fixed to 10
seconds. In the “Normal ode”, it according to the setting of the
configuration NO. 6.
5