HD9040
2-6
Control Panel Inspection Instruction
Bread maker test program:
Press the “START/STOP” button during Mains connection, then release the “START/STOP” button.
The system enters into diagnosis status, the LCD shows “1229” which indicates the software version. Press any other button except
“START/STOP” to switch to other tests.
Press
Start/Stop
Button
LCD
shows Which Indicates Possible root cause Replace
1st time 1 Motor is running 1. Wrong connection between PCB and
motor
2. Motor error
Motor assy or PCB
2nd time 2 Motor stops running
3rd time 3 Motor is running clockwise 1. Wrong connection between PCB and
motor
2. Motor error
Motor assy or PCB
4th time 4 Motor stops running
5th time 5 No functions
6th time 6 No functions
7th time 7 Heater start heating 1. Heater failure
2. PCB failure
Heating element or PCB
8th time 8 Heater stops heating
9th time 9 Heater and motor operate at
the same time
1. Heater failure
2. PCB failure
3. Motor error
10th time 10 Heater and motor stop
operating
In test 1 till 8 is OK
replace PCB
11th time 11 Buzzer starts 1. Buzzer inserts wrong or damage
2. PCB failure
PCB
12th time 12 Buzzer stops
13th time 13 Power indicater Power indicator insert wrong or damage; Replace control panel
14th time 14 Power indicater
15th time 15 All LCD contents will be on 1. LCD failure
2. PCB failure
Control panel assy
16th time 16 All LCD contents will be off * 1. LCD failure
2. PCB failure
Control panel assy
17th time 17F1 F1” indicates the AD value for
the temperature of the sensor
If room temp is among 35-20-10, the AD
value will be among EA~F5~F8, if the room
temp out of spec, AD value will out of range
EA~F5~F8. **
Root cause might be: PCB failure / Temp
sensor
PCB or Temp sensor
18th time 18 8E AD value for temperature
sensor sampling should be in
room temperature
If the temperature is between 35-20-10
degrees, the AD value should be between
73~9E~b5.
Attention, if the room temperature is not in
this scope, the AD value is out of spec.**
Root cause might be: PCB failure / Temp
sensor
PCB or Temp sensor
One more
time press
It will return to software
interface and repeat cyclically
REPAIR INSTRUCTIONS