Philips MasterColor 281352 User manual

37/16"
57/16"
MasterColor®Metal Halide
100W ED-17 4K (Clear)
FeaturingALTO®LampTechnology
◗Ordering Information
Ordering Code MHC100/U/M/4K/ALTO
ANSI Designation M140/M90/E
Product Number 281352
Description MasterColor Metal Halide
Package Quantity 12
◗Physical Characteristics
Bulb Size ED-17
Bulb Finish Clear
Base Medium-Screw
Max.Overall Length (MOL) 5 7/16'' (138mm)
Light Center Length (LCL) 3 7/16'' (87mm)
Arc Length 0.6'' (14mm)
ArcTube Material Poly Crystalline Alumina
Max.Permissible BulbTemp. 400ºC (752ºF)
Max.Permissible BaseTemp. 190ºC (374ºF)
Max.Bulb to Base Eccentricity 3º
Max.ArcTube to Base Eccentricity 3º
◗Operating Characteristics (Photometric)
Rated Initial Lumens19000
Mean Lumens,Approx.26750
RatedAverage Life,Hours 20,000
Correlated ColorTemp.(CCT)24000K
CIE ChromaticityApprox.2
x-.376,y-.371
Color Rendering Index (CRI) 92
Efficacy (lpw) 68
◗Operating Position
Universal—Enclosed Luminaires Only
Note:Electronic ballasts are preferred for optimum performance,
energy efficiency and circuit loading.
MasterColor® Spectral Power Distribution—4KTypes
RELATIVE ENERGY
400 450 500 550 600 650 700
WAVELENGTH (Nanometers)
350
300
250
200
150
100
50
0
40
50
60
70
80
90
100
0 5000 15000
Percent Lumen Maintenance
Burning Hours
Average Lumen Maintenance Curve, MHC100/U/M/4K
Clear and Coated
10000 20000
1) Measured at 100 hrs of life in vertical position.
2) Measured at rated lamp watts on a linear reactor. LPW does not include ballast losses.
3) Measured with the lamp operating at rated watts.
Electrical Data (Subject to change without notice)
Warnings, Cautions and Operating Instructions
“WARNING: These lamps can cause serious skin burn and eye inflammation
from short wave ultraviolet radiation if outer envelope of the lamp is broken or
punctured.Do not use where people will remain for more than a few minutes
unless adequate shielding or other safety precautions are used. Certain lamps
that will automatically extinguish when the outer envelope is broken or punctured
are commercially available.”This lamp complies with FDA radiation performance
standard 21 CFR subchapter J.(USA:21CFR 1040.30 Canada:SOR/DORS/80-381)
If the outer bulb is broken or punctured,turn off at once and replace
the lamp to avoid possible injury from hazardous short wave ultraviolet
radiation.Do not scratch the outer bulb or subject it to pressure as
this could cause the outer bulb to crack or shatter.A partial vacuum
in the outer bulb may cause glass to fly if the envelope is struck.
WARNING: The arc-tube of metal halide lamps are designed to operate under
high pressure and at temperatures up to 1000ºC and can unexpectedly rupture
due to internal or external factors such as a ballast failure or misapplication.If the
arc-tube ruptures for any reason,the outer bulb may break and pieces of extremely
hot glass might be discharged into the surrounding environment.If such a rupture
were to happen,THERE IS A RISK OF PERSONAL INJURY, PROPERTY
DAMAGE,BURNSAND FIRE.
Certain lamps that will retain all the glass particles should inner arc-tube rupture
occur are commercially available from Philips Lighting Company.
RELAMP FIXTURESAT OR BEFORETHE END OF RATED LIFE.
Allowing lamps to operate until they fail is not advised and may
increase the possibility of inner arc tube rupture.
This lamp contains an arc tube with a filling gas containing Kr-85 and is distrib-
uted by Philips Lighting Company, a division of Philips Electronics NorthAmerica
Corporation,Somerset, New Jersey 08875-6800.
CAUTION: TO REDUCETHE RISK OF PERSONAL INJURY,PROPERTY
DAMAGE,BURNSAND FIRE RESULTING FROMANARC-TUBE RUPTURE
THE FOLLOWING LAMP OPERATING INSTRUCTIONS MUST BE FOLLOWED.
Lamp Operating Instructions:
1) RELAMP FIXTURESAT OR BEFORETHE END OF RATED LIFE.Allowing
lamps to operate until they fail is not advised and may increase the possibility
of inner arc tube rupture.
2) Use only in an enclosed fixture capable of withstanding particles of glass
having temperatures up to 1000ºC.
3) Before lamp installation/replacement, shut power off and allow lamp and
fixture to cool to avoid electrical shock and potential burn hazards.
4) Use only auxiliary equipment meeting Philips and/or ANSI standards.
Use within voltage limits recommended by ballast manufacturer.
A.Operate lamp only within specified limits of operation.
B. For total supply load refer to ballast manufacturers electrical data.
5) Periodically inspect the outer envelope. Replace any lamps that show
scratches,cracks or damage.
6) If a lamp bulb support is used,be sure to insulate the support electrically
to avoid possible decomposition of the bulb glass.
7) Protect lamp base,socket and wiring against moisture,corrosive atmospheres
and excessive heat.
8)Time should be allowed for lamps to stabilize in color when turned on for
the first time.This may require several hours of operation,with more than
one start. Lamp color is also subject to change under conditions of excess
vibration or shock,and color appearance may vary between individual lamps.
9) Lamps may require 10 to 20 minutes to re-light if there is a power interruption.
10)Take care in handling and disposing of lamps.If an arc tube is broken, avoid
skin contact with any of the contents or fragments.
Philips Lighting Company
200 Franklin Square Drive ■P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
www.lighting.philips.com/nam
A Division of Philips Electronics NorthAmerica Corporation
Updated 7/03 MHC 011-A
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
www.lighting.philips.com/nam
A Division of Philips Electronics Ltd.
MasterColor®Metal Halide 100Watt ED-17 4K (Clear) Lamp Featuring ALTO®LampTechnology
LampWatts (Nominal). . . . . . . . . . . . . . . . . . . . . . . . . 100
Lamp OperatingVoltage (rms) (Nominal)2
. . . . . . . . . . 102
Initial LampVoltage Range (rms)3
. . . . . . . . . . . . . . . . . 82–112
Lamp Operating Current (Amps) (rms) (Nominal). . . . 1.1
Lamp Current Crest Factor (Maximum). . . . . . . . . . . . 1.8
Warm-upTime to 80% of Output . . . . . . . . . . . . . . . . 2 Minutes
Re-strikeTime for Hot Lamp. . . . . . . . . . . . . . . . . . . . 4–8 Minutes
BallastType. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ANSI M140/M90/E
Ballast Open CircuitVoltage (Minimum). . . . . . . . . . . . 249 RMS Min.
Pulse PeakVolts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3300 Min.,4000 Max.
PulseWidth @ 90% Peak. . . . . . . . . . . . . . . . . . . . . . . 2 Micro Second Minimum
Pulse Repetition Rate (Minimum). . . . . . . . . . . . . . . . . 2 per Half Cycle
Minimum OperatingTemperature. . . . . . . . . . . . . . . . . -30ºC

This manual suits for next models

1

Other Philips Light Bulb manuals

Philips T25 E14 User manual

Philips

Philips T25 E14 User manual

Philips Twist Line Reflector Lamp User manual

Philips

Philips Twist Line Reflector Lamp User manual

Philips HPL-N User manual

Philips

Philips HPL-N User manual

Philips EcoClassic 872790082098000 User manual

Philips

Philips EcoClassic 872790082098000 User manual

Philips Master PL-T Xtra 4 pin User manual

Philips

Philips Master PL-T Xtra 4 pin User manual

Philips ACCENTline Reflector Lamps User manual

Philips

Philips ACCENTline Reflector Lamps User manual

Philips MASTERline ES User manual

Philips

Philips MASTERline ES User manual

Philips MASTER TL-D Super 80 HF User manual

Philips

Philips MASTER TL-D Super 80 HF User manual

Philips PLUS T8 U-Bent User manual

Philips

Philips PLUS T8 U-Bent User manual

Philips MasterColor 281337 User manual

Philips

Philips MasterColor 281337 User manual

Philips T22 B15d User manual

Philips

Philips T22 B15d User manual

Philips de Luxe TL-D 90 User manual

Philips

Philips de Luxe TL-D 90 User manual

Philips SOX User manual

Philips

Philips SOX User manual

Philips P-5643-A 7002Y User manual

Philips

Philips P-5643-A 7002Y User manual

Philips Alto CDM-i25w User manual

Philips

Philips Alto CDM-i25w User manual

Philips T8 Lamps P-5338-G User manual

Philips

Philips T8 Lamps P-5338-G User manual

Philips TL-D User manual

Philips

Philips TL-D User manual

Philips Halogen Lamps User manual

Philips

Philips Halogen Lamps User manual

Philips HalogenA PAR 38 User manual

Philips

Philips HalogenA PAR 38 User manual

Philips A60 B22d User manual

Philips

Philips A60 B22d User manual

Philips T17 E14 User manual

Philips

Philips T17 E14 User manual

Philips 800 series User manual

Philips

Philips 800 series User manual

Philips ecoMOODS 40399 User manual

Philips

Philips ecoMOODS 40399 User manual

Philips Alto Plus Slimline 8 User manual

Philips

Philips Alto Plus Slimline 8 User manual

Popular Light Bulb manuals by other brands

Sengled Element E11-G13 user manual

Sengled

Sengled Element E11-G13 user manual

Merkury Innovations MI-BW902-999 Start guide

Merkury Innovations

Merkury Innovations MI-BW902-999 Start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.