manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Philips
  6. •
  7. Work Light
  8. •
  9. Philips MasterColor P-5496-E User manual

Philips MasterColor P-5496-E User manual

Philips MasterColor®
Protected Pulse Start
Ceramic Metal Halide
Lamps featuring ALTO®
Lamp Technology
Ideal for use in high-ceiling
retail, distribution center or
industrial applications
CERAMIC METAL HALIDE
† This lamp is better for the environment because of
its reduced mercury content. All Philips ALTO®lamps
give you end-of-life options which can simplify and
reduce your lamp disposal costs depending on your
state and local regulations.
Ceramic arc tube technology for
outstanding color performance
Philips MasterColor®Protected Pulse Start Ceramic Metal Halide lamps
offer a range of protected high-efficiency long life medium wattage lamps with
a stable lumen maintenance over lifetime and provides crisp, sparkling light.
Higher lumen maintenance
• Improved lumen maintenance increases time between re-lamping
• 75% lumen maintenance at 24,000 hours*
Superior color stability over life
• Within ±200K for consistent look and feel of the space
• Excellent color rendering—90 CRI
Operates on metal halide pulse start ballasts
Patented coil design offers protection for open fixture rating
No shut off required
• Ideal for 24-hours-a-day, 7-days-a-week operations
(relamp fixtures at or before the end of rated average life)
Patented dual frame construction for improved reliability
and increased life
(* See back of page for footnotes)
P-5496-E MC PPS CMH.qxd:Layout 1 9/16/08 10:54 AM Page 1
© 2008 Philips Lighting Company. All rights reserved.
Printed in USA 09/08
P-5496-E
www. philips.com
Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
A Division of Philips Electronics North America Corporation
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
Printed on chlorine free paper from Sappi Fine Paper mills, who are accredited with EMAS environmental certification.
Sappi claims that the pulp used in the manufacture of Magno Dull paper is derived from environmentally certified forests.
Philips MasterColor®Protected Pulse Start Ceramic Metal Halide Lamps
Ordering Data
Color Rated Approx Approx
Product Nom. Pkg. ANSI LCL MOL Temp. Avg. Life Initial Mean
Number Ordering Code Watts Bulb Base Qty. Code (In.) (In.) (Kelvin) CRI (Hrs.) Lumens1Lumens2
20583-1 CDM250/V/O/PS/4K/ALTO 250 ED-28 EX39 12 C153/M153/O 5" 8.5" 4200 90 24,000 22,500 18,000
20584-9 CDM250/C/V/O/PS/4K/ALTO 250 ED-28 EX39 12 C153/M153/O 5" 8.5" 4200 90 24,000 21,300 17,000
13291-0 CDM320/V/O/PS/4K/ALTO 320 ED-28 EX39 12 M170/M132/O 5" 8.5" 4200 90 24,000 28,800 23,000
13256-3 CDM320/C/V/O/PS/4K/ALTO 320 ED-28 EX39 12 M170/M132/O — 8.5" 4200 90 24,000 28,000 22,400
13257-1 CDM350/V/O/PS/4K/ALTO 350 ED-37 EX39 6 M171/M131/O 7" 11.5" 4200 90 24,000 31,500 25,200
13292-8 CDM350/C/V/O/PS/4K/ALTO 350 ED-37 EX39 6 M171/M131/O — 11.5" 4200 90 24,000 30,600 24,500
14598-6 CDM400/V/O/PS/4K/ED28/ALTO 400 ED-28 EX39 12 M172/M155/O 5" 8.5" 4200 90 20,000 36,000 28,800
13290-2 CDM400/V/O/PS/4K/ALTO 400 ED-37 EX39 6 M172/M155/O 7" 11.5" 4200 90 24,000 36,000 28,800
13293-6 CDM400/C/V/O/PS/4K/ALTO 400 ED-37 EX39 6 M172/M155/O — 11.5" 4200 90 24,000 35,000 27,900
1) Approximate lumen values listed are for vertical operation of the lamp.
2) Approximate lumen output at 40% of lamp rated average life.
3) Measured at 100 hrs of life in vertical position.
4) Measured at rated lamp watts on a linear reactor. LPW does not include ballast losses.
5) Rated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start. It is based on survival of at least
50% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average. For lamps with a rated average life of 24,000 hours, life is based on survival of 67% of the lamps.
6) Measured with the lamp operating at rated watts.
This product utilizes ALTO®Lamp Technology. ALTO products pass the US EPA's Toxicity Characteristic Leaching Procedure (TCLP) and can be classified as non-hazardous waste.
Check with state and local regulations.
* 75% lumen maintenance at 20,000 hours for product number 14598-6.
Above specifications subject to change without notice.
R
“WARNING: These lamps can cause serious skin burn and eye inflammation from short wave ultraviolet
radiation if outer envelope of the lamp is broken or punctured. Do not use where people will remain for
more than a few minutes unless adequate shielding or other safety precautions are used. Certain lamps that will
automatically extinguish when the outer envelope is broken or punctured are commercially available.”This lamp
complies with FDA radiation performance standard 21 CFR subchapter J. (USA:21CFR 1040.30
Canada:SOR/DORS/80-381)
If the outer bulb is broken or punctured, turn off at once and replace the lamp to avoid possible
injury from hazardous short wave ultraviolet radiation. Do not scratch the outer bulb or subject it to
pressure as this could cause the outer bulb to crack or shatter.A partial vacuum in the outer bulb may
cause glass to fly if the envelope is struck.
WARNING: The arc-tube of metal halide lamps are designed to operate under high pressure and at temperatures
up to 1000º C and can unexpectedly rupture due to internal or external factors such as a ballast failure or
misapplication. If the arc-tube ruptures for any reason, the outer bulb may break and pieces of extremely hot
glass might be discharged into the surrounding environment. If such a rupture were to happen, THERE IS A
RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
These lamps are designed to retain all the glass particles should an arc tube rupture occur.The
following operating instructions are recommended to minimize these occurrences.
RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE.Allowing lamps to operate until
they fail is not advised and may increase the possibility of inner arc tube rupture.
This lamp contains an arc tube with a filling gas containing Kr-85 and is distributed by Philips
Lighting Company, a division of Philips Electronics North America Corporation, Somerset,
New Jersey, 08875.
CAUTION: TO REDUCE THE RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE
RESULTING FROM AN ARC-TUBE RUPTURETHE FOLLOWING LAMP OPERATING INSTRUCTIONS
MUST BE FOLLOWED:
LAMP OPERATING INSTRUCTIONS:
1. RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE. Allowing lamps to operate until they fail is not
advised and may increase the possibility of inner arc tube rupture.
2. Before lamp installation/replacement, shut power off and allow lamp and fixture to cool to avoid electrical shock and
potential burn hazards.
3. Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended by
ballast manufacturer.
A. Operate lamp only within specified limits of operation.
B. For total supply load refer to ballast manufacturers electrical data.
C. All Pulse Start mogul based lamps require a socket rated to withstand a 4000 volt pulse.
4. Periodically inspect the outer envelope. Replace any lamps that show scratches, cracks or damage.
5. If a lamp bulb support is used, be sure to insulate the support electrically to avoid possible decomposition of
the bulb glass.
6. Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat.
7. Time should be allowed for lamps to stabilize in color when turned on for the first time. This may require several
hours of operation, with more than one start. Lamp color is also subject to change under conditions of excess
vibration or shock, and color appearance may vary between individual lamps.
8. Lamps may require 10 to 20 minutes to re-light if there is a power interruption.
9. Take care in handling and disposing of lamps. If an arc tube is broken, avoid skin contact with any of the contents
or fragments.
10. Use this lamp only in fixtures that contain Pulse Start metal halide ballasts and are specifically
designed for use
with Pulse Start metal halide lamps.
P-5496-E MC PPS CMH.qxd:Layout 1 9/16/08 10:54 AM Page 2

This manual suits for next models

1

Other Philips Work Light manuals

Philips LivingColors 6914748PU User manual

Philips

Philips LivingColors 6914748PU User manual

Philips LivingColors SA1307-120060EU User manual

Philips

Philips LivingColors SA1307-120060EU User manual

Philips LivingColors 6916665PH User manual

Philips

Philips LivingColors 6916665PH User manual

Philips Xperion 3000 Pocket User manual

Philips

Philips Xperion 3000 Pocket User manual

Philips LivingColors 6950060PU User manual

Philips

Philips LivingColors 6950060PU User manual

Philips WE Series User manual

Philips

Philips WE Series User manual

Philips Xitanium Xitanium User manual

Philips

Philips Xitanium Xitanium User manual

Philips LivingColors 6917530PH User manual

Philips

Philips LivingColors 6917530PH User manual

Philips GreenPower LED series User manual

Philips

Philips GreenPower LED series User manual

Philips LivingColors 6917155PU User manual

Philips

Philips LivingColors 6917155PU User manual

Philips LivingColors 6916660PU User manual

Philips

Philips LivingColors 6916660PU User manual

Philips LivingColors 6950230PH User manual

Philips

Philips LivingColors 6950230PH User manual

Philips LivingColors 6917548PH User manual

Philips

Philips LivingColors 6917548PH User manual

Philips GreenPower LED series User manual

Philips

Philips GreenPower LED series User manual

Philips Lightolier Skyway SKSGPK228 User manual

Philips

Philips Lightolier Skyway SKSGPK228 User manual

Philips C2 Series User manual

Philips

Philips C2 Series User manual

Philips LivingColors 6917160PU User manual

Philips

Philips LivingColors 6917160PU User manual

Philips LivingColors 6950030PU User manual

Philips

Philips LivingColors 6950030PU User manual

Philips WE4X Series User manual

Philips

Philips WE4X Series User manual

Philips 220-230-240V User manual

Philips

Philips 220-230-240V User manual

Philips LivingColors Mini User manual

Philips

Philips LivingColors Mini User manual

Philips LivingColors Generation2 69171/**/** Series User manual

Philips

Philips LivingColors Generation2 69171/**/** Series User manual

Philips LivingColors 6917155PH User manual

Philips

Philips LivingColors 6917155PH User manual

Philips Xperion 3000 Zoom User manual

Philips

Philips Xperion 3000 Zoom User manual

Popular Work Light manuals by other brands

Intex Lumo manual

Intex

Intex Lumo manual

Ignition Stagepix Line 100 IP user manual

Ignition

Ignition Stagepix Line 100 IP user manual

EUFAB SMD LED 8+1 operating instructions

EUFAB

EUFAB SMD LED 8+1 operating instructions

Monzana Spodaj MZUL277 manual

Monzana

Monzana Spodaj MZUL277 manual

Makita DML814 instruction manual

Makita

Makita DML814 instruction manual

Velleman Perel EWL415T user manual

Velleman

Velleman Perel EWL415T user manual

IKEA NORRFLY manual

IKEA

IKEA NORRFLY manual

Osram LUMINESTRA LED 8W quick start guide

Osram

Osram LUMINESTRA LED 8W quick start guide

Show Tec Titan Strobe blaze manual

Show Tec

Show Tec Titan Strobe blaze manual

Parkside PAL 2200 A2 manual

Parkside

Parkside PAL 2200 A2 manual

UNILITE RA-700R quick start guide

UNILITE

UNILITE RA-700R quick start guide

Hightstick NSR-1514 instruction manual

Hightstick

Hightstick NSR-1514 instruction manual

Milwaukee M18 PAL Original instructions

Milwaukee

Milwaukee M18 PAL Original instructions

Conrad IM859 operating instructions

Conrad

Conrad IM859 operating instructions

ring RIL5300HPB manual

ring

ring RIL5300HPB manual

Bosch GLI VariLED Professional Original instructions

Bosch

Bosch GLI VariLED Professional Original instructions

Makita DML184 instruction manual

Makita

Makita DML184 instruction manual

Pro-Elec PEL0L0361 manual

Pro-Elec

Pro-Elec PEL0L0361 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.