Page 1.4 RESOURCE DISTRIBUTOR & BUS MATRIX INPUTS MODULE 40-569B
pickering
SECTION 1 - TECHNICAL SPECIFICATION
Resource Distributor & Bus Matrix Inputs, 40-569B
pickeringtest.com
Specifications
Switching Specification
Switch Type: Electro-mechanical
Contact Type: Palladium-Ruthenium,
Gold Covered Bifurcated
Max Hot Switch Voltage:
Max Cold Switch Voltage:
200 VDC/180 VAC*
270 VDC/180 VAC*
(maximum voltage slew
rate 3 V/µs)
Max Power:
Max Switch Current:
Max Continuous Carry Current:
Max Pulsed Carry Current
Example (for a single switch
path):
60 W/62.5 VA
2 A †
2 A †
6 A for 100 ms
(up to 10 % duty cycle)
Initial Path Resistance (Bus
Matrix Inputs to Resource
Distributor)
On:
Off:
Minimum Voltage:
Differential Thermal Offset:
<1000 mΩ
>109 Ω
100 µV
<10 µV
Operate Time: <3 ms typical,
single operation
Expected Life (operations)
Very low power signal load:
Low power load (2 W):
Medium power load (30 W):
Full power load (60 W):
>1x108
>1.5x107 (0.1 A 20V DC)
>5x106 (1 A 30 VDC)
>1x105 (2 A 30 VDC)
Bus Matrix Inputs isolation
path resistors:
100 kΩ, 0.5 W, 1 %
* For full voltage rating, signal sources to be switched
must be fully isolated from mains supply and safety earth.
† Please be aware of switch path current restriction with
Bus Matrix Inputs isolation path resistors in circuit
Power Requirements
+3.3 V +5 V +12 V -12 V
0 <4 A (typ 1 A) 0 0
Operating/Storage Conditions
Operating Conditions
Operating Temperature:
Humidity:
Altitude:
0 °C to +55 °C
Up to 90 % non-condensing
5000 m
Storage and Transport Conditions
Storage Temperature:
Humidity:
Altitude:
-20 °C to +75 °C
Up to 90 % non-condensing
15000 m
PXI & CompactPCI Compliance
The module is compliant with the PXI Specification
2.2. Local Bus, Trigger Bus and Star Trigger are not
implemented.
Uses a 33 MHz 32-bit backplane interface.
Safety & CE Compliance
All modules are fully CE compliant and meet
applicable EU directives: Low-voltage safety EN61010-
1:2010, EMC Immunity EN61326-1:2013, Emissions
EN55011:2009+A1:2010.
Width and Dimensions
Four or eight slot 3U PXI module (CompactPCI).
3D models for these modules in a variety of popular file
formats are available on request.
Module Weight
Empty BRIC Fully Loaded BRIC
BRIC4 0.9 Kg 2.1 Kg
BRIC8 1.6 Kg 4.0 Kg
BRIC daughter card 0.2 Kg
Connectors
PXI bus via 32-bit P1/J1 backplane connector.
Connections are made to the Bus Matrix Inputs card via a
front panel 160-pin male DIN 41612 connector (includes a
strain relief fixing for use with Pickering’s cableforms).
Connections are made to the Resource Distributor card via
a front panel 50-pin male D-type connector.
Note:
We recommend that Pickering mating connectors are used
with this module. These are designed to ensure there are no
mechanical interference problems when used in a PXI chassis.
Relay Type
The 40-569B BRIC modules are fitted with electro-mechanical
relays.
Typical Bandwidth and Crosstalk
Bandwidth (-3 dB): >8 MHz
Crosstalk (typical): 10 kHz:
100 kHz:
1 MHz:
10 MHz:
-60 dB
-50 dB
-30 dB
-12 dB
Isolation: 10 kHz:
100 kHz:
1 MHz:
10 MHz:
>90 dB
>80 dB
>56 dB
>36 dB
Maximum Crosspoint Count
The 40-569B has a suggested maximum number of
simultaneously operated crosspoints of 104, please refer to
manual for detailed breakdown. Higher closure counts are
possible, please contact sales office for further information.