PLUSOPTIX S12C How to use

plusoptiX S12C & S12R –Short Manual
English, MS, 20.01.2016
Handling of the device
wrong right
Measurement requirements
1. The examination room should only be slightly illuminated, i.e. no direct
daylight. Halogen spotlights and light bulbs are emitting infrared light and
should be switched off during measurements. Fluorescent lamps and
energy-saving lamps are permitted for lightning the room.
2. Please make sure that the child is not distracted during the measurement.
3. Switch on the device . When the start screen appears, please select the
age-group of the child and start the measurement by pressing the orange
measurement button next to the screen.
4. The measurement is performed from a distance of one meter (+/- 5 cm)
from the child. Start the measurement from approximately 1,2 m distance
to the child. Move forward until the pupils are clear and outlined with
green circles. At this moment the sound will appear again to signalize that
the measurement starts now.
5. It is important to hold the camera on eye-level when performing a
measurement. Please make sure that the pupils are not covered by
eyelashes, the eyelid or hair. If no screening result appears, a status
message will be displayed. In this case please follow the instructions,
outlined on the rear side of this page.
plusoptiX S12C
plusoptiX S12R
12VDC
input
SD
card
Mini
USB
USB
On/Off button
Shutter
button
Touchscreen
Touchscreen
12VDC
input
SD
card
Mini
USB
USB
Shutter
button
On/Off button
1m ± 5 cm
English, MS, 20.01.2016
Choose referral criteria
The examiner can choose
between five different ROC
curves (Receiver Operating
Characteristics), which differ in
sensitivity and specificity, due to
different studies. ROC 1 is the
pre-set curve, which is based on
a study of the University Eye
Hospital Munich.
To perform screenings with
lower sensitivity but higher
specificity choose one of the
other ROC curves (2-5). Keep in mind that choosing a lower sensitivity will
increase the number of positive children, who are overlooked.
Screening Result of plusoptiX S12C & S12R
If the status message “Refer”is
displayed, the child must be sent
to an eye specialist for a
complete eye examination.
If the status message “Refer or
try again” is displayed, follow the
instructions on the screen and
measure again. If you get “Refer
or try again” again, please send
the child precautionally to an eye
specialist.
If the status message “Try again” is displayed, the measurement was aborted
because of an user error. In this case, please follow the instructions on the
screen and measure again.
Status-messages
Pupils not found: Restart the measurement on eye level of the child and make
sure the pupils are not covered by hair, eyelashes or the eyelid.
Pupils too big: The size of one or both pupils is over 8 mm. Increase the
lightning in the room so that the pupils get smaller.
Pupils too small: The size of one or both pupils is below 4 mm. Decrease the
lightning in the room so that the pupils get bigger.
Camera picture out of focus: Please make sure to have the right distance to
the patient (1m +/- 5cm).
Too much IR ambiance light: Close the curtains to avoid too much daylight in
the room.
Patient does not focus the camera: Please measure again and make sure the
patient is focusing on the nose of the smiling face on the camera.
Measurement incomplete: The measurement result is n/a. Repeat the
measurement and make sure that the pupils are not covered by hair, eyelashes
or the eyelid.
Corneal reflexes are too dark: Dim room light so that the pupils get bigger.
A detailed description of the status messages and its reasons can be found in
the user manual point 4.2.3. “Error messages when performing a
measurement”.
Failure message
A status message will appear in
case no measurement result is
displayed on the screen.
Instruction what to do
Status message

Other manuals for S12C

7

This manual suits for next models

1

Other PLUSOPTIX Medical Equipment manuals

PLUSOPTIX A12C How to use

PLUSOPTIX

PLUSOPTIX A12C How to use

PLUSOPTIX S16 How to use

PLUSOPTIX

PLUSOPTIX S16 How to use

PLUSOPTIX A09 User manual

PLUSOPTIX

PLUSOPTIX A09 User manual

PLUSOPTIX A12C Quick start guide

PLUSOPTIX

PLUSOPTIX A12C Quick start guide

PLUSOPTIX A12C How to use

PLUSOPTIX

PLUSOPTIX A12C How to use

PLUSOPTIX S12C How to use

PLUSOPTIX

PLUSOPTIX S12C How to use

PLUSOPTIX A12R Technical manual

PLUSOPTIX

PLUSOPTIX A12R Technical manual

PLUSOPTIX S12C Technical manual

PLUSOPTIX

PLUSOPTIX S12C Technical manual

PLUSOPTIX S12C How to use

PLUSOPTIX

PLUSOPTIX S12C How to use

PLUSOPTIX A12C How to use

PLUSOPTIX

PLUSOPTIX A12C How to use

PLUSOPTIX A12C How to use

PLUSOPTIX

PLUSOPTIX A12C How to use

PLUSOPTIX S12R Technical manual

PLUSOPTIX

PLUSOPTIX S12R Technical manual

PLUSOPTIX S12C How to use

PLUSOPTIX

PLUSOPTIX S12C How to use

PLUSOPTIX S12R User manual

PLUSOPTIX

PLUSOPTIX S12R User manual

PLUSOPTIX A12C How to use

PLUSOPTIX

PLUSOPTIX A12C How to use

PLUSOPTIX S12R User manual

PLUSOPTIX

PLUSOPTIX S12R User manual

PLUSOPTIX Vision Screener User manual

PLUSOPTIX

PLUSOPTIX Vision Screener User manual

PLUSOPTIX S12C How to use

PLUSOPTIX

PLUSOPTIX S12C How to use

PLUSOPTIX S12R How to use

PLUSOPTIX

PLUSOPTIX S12R How to use

PLUSOPTIX S16 Technical manual

PLUSOPTIX

PLUSOPTIX S16 Technical manual

PLUSOPTIX S12C User manual

PLUSOPTIX

PLUSOPTIX S12C User manual

PLUSOPTIX Binocular Autorefractor How to use

PLUSOPTIX

PLUSOPTIX Binocular Autorefractor How to use

PLUSOPTIX S12C How to use

PLUSOPTIX

PLUSOPTIX S12C How to use

PLUSOPTIX Vision Screener How to use

PLUSOPTIX

PLUSOPTIX Vision Screener How to use

Popular Medical Equipment manuals by other brands

Erbe LAP BiSect Dismantling and Assembling

Erbe

Erbe LAP BiSect Dismantling and Assembling

North Coast Hemi Sling NC15999 quick start guide

North Coast

North Coast Hemi Sling NC15999 quick start guide

Canon CXDI-50G user manual

Canon

Canon CXDI-50G user manual

Sunrise Medical Guardian IC-5307 User instructions and warranty

Sunrise Medical

Sunrise Medical Guardian IC-5307 User instructions and warranty

Planmeca ProMax 3D Mid user manual

Planmeca

Planmeca ProMax 3D Mid user manual

Howard Industries PHACOJACK Operator's manual

Howard Industries

Howard Industries PHACOJACK Operator's manual

Mindray BeneView T1 Operator's manual

Mindray

Mindray BeneView T1 Operator's manual

Hillrom CarePorter P3000 Service manual

Hillrom

Hillrom CarePorter P3000 Service manual

Bionet BM3 user manual

Bionet

Bionet BM3 user manual

NSK VarioSurg 3 Operation manual

NSK

NSK VarioSurg 3 Operation manual

Contec CMS50M user manual

Contec

Contec CMS50M user manual

Seca 525 Instructions for use

Seca

Seca 525 Instructions for use

Bionet CardioXP Operation manual

Bionet

Bionet CardioXP Operation manual

Erbe EIP 2 Service manual

Erbe

Erbe EIP 2 Service manual

Atmos C 161 operating instructions

Atmos

Atmos C 161 operating instructions

COOK Medical BIGopsy IFU0034-4 manual

COOK Medical

COOK Medical BIGopsy IFU0034-4 manual

Babycare TENS Obi TENS Instructions for use

Babycare TENS

Babycare TENS Obi TENS Instructions for use

CAE BPDA230-AP user guide

CAE

CAE BPDA230-AP user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.