6
EVD-2•5401042•REVL•03/05
EVD-M CONTROLLER
The EVD-M controller is a microprocessor controlled, vibration detector that incorporates advanced
detection methods for identifying all common types of attacks. It detects short duration, large amplitude
signals like those produced in attacks from explosions, hammering or chiseling. It also detects long
duration, small amplitude signals like those produced in attacks from torches, thermic lances, drills,
grinders or cutting discs. As soon as the EVD-M detects a large amplitude alarm source it signals an
alarm. Small amplitude alarm sources must persist for 15 seconds before the EVD-M signals an alarm.
Alarm contacts operate for a minimum of 2 seconds.
The EVD-M contains two sensitivity adjustments: one for EVD-M’s internal pickup, another one for a
network of remote pickups. The EVD-M controller supports up to 15 EVD-R remote pickups, (or may be
used as a stand alone unit), and fully supervises EVD-R wiring. The EVD-M signals wiring faults as
alarms. A cover tamper and a back tamper protect the EVD-M from cover removal or prying. If either
tamper on the EVD-M activates or any remote pickup signals tamper, the EVD-M will signal a tamper
alarm condition. Tamper alarm contacts operate for a minimum of 2 seconds. If more than five remote
pickups signal a tamper condition, the EVD-M will signal an alarm. The internal pickup of the EVD-M is
always active, regardless of any tamper condition.
The model EVD-M controller provides a Form C, alarm contact for connection into the alarm protective
circuit. Additionally, the EVD-M provides an independent, Form A, tamper alarm contact which can be
wired as a separate 24 hour alarm circuit or wired in series with the alarm protective circuit. The EVD-M
includes accessory terminals for an alarm condition remote annunciator, a tamper alarm remote
annunciator, and a remote test input. The remote test input terminal permits the connection of dry
contacts from any Underwriters Laboratories listed central station test unit. The remote test annunciator,
model RTA, provides a normally open test switch and alarm and tamper alarm annunciators that interface
directly to the accessory terminals of the EVD-M.
In addition to its remote test capability, the EVD-M provides a magnetically activated test switch that
permits testing of the installation. The EVD-M contains a multi-color LED to indicate system status. This
status LED indicates several states:
NOTES:
1. If both an alarm condition and a tamper condition exist, the status LED will indicate RED for the
alarm. The remote annunciators and the alarm and tamper alarm contacts will indicate both alarm
and tamper alarm conditions.
2. If the microprocessor fails, the status LED will blink RED and both the alarm and tamper alarm
contacts will be activated.
ACCUMULATOR FUNCTION
The EVD-M contains a rotary switch that controls the EVD-M’s accumulator setting. This accumulator,
when activated, accumulates impact events. When the number of valid signals matches the setting on the
rotary switch, the EVD-M signals an alarm. This feature can be useful for installing an EVD-2 system
where some noise is normal. The accumulator is only active when the rotary switch setting is NOT zero.
The threshold for valid signals is controlled by the sensitivity settings for the internal pickup and the
remote pickups. If EVD-M has not detected enough valid signals for an alarm and five minutes pass after
the last valid signal, the EVD-M resets the accumulator count to zero. As an aid to installers, the EVD-M
blinks its status LED for each valid accumulator signal that it detects. (This feature is only active while
the EVD-M cover is off and if the accumulator is activated, i.e.. during installation.) An analog test
point provides signal level information to simplify installations.
Refer to Figure 1 for key component locations and terminal descriptions.
WARNING: If the main burglar panel has ground fault detection circuitry, it may be necessary to
power the EVD from a separate power supply, not from the auxiliary power on the burglar panel.
Alternately, the safe may be insulated from ground.
sutatSM-DVE DELsutatS roloC stcatnoCmralAstcatnoCmralArepmaT
lamroN neerGevitcanIevitcanI
repmaT )1(rebmAevitcan
IevitcA
mralA )2(deRevitcA)1(evitcAroevitcanI
rewoPoN ffOevitcAevitcA