PAD300-RB
SLC Voltage 24 VDC
SLC Standby / Alarm Current (*) 200 A
Relay Rating 2A @ 30 VDC
0.5A @ 125 VAC
Installation Temp Range 32F to 150F
Operating Humidity Range 0% - 93% (Non-condensing)
Dimension Φ 6.4 in
Weight 7.05 oz
Height 1.57 in
*Standby current is the current the device consumes when the device
is in a non-activated condition and where no communication current
is transmitted to the re alarm control panel.
e PAD300-RB is an addressable relay base. It is
compatible with Potter’s addressable re alarm control
panels.
e PAD300-RB is a mounting base designed to work
specially with the PAD300 series detectors. Compatible
detectors include PAD300-PD, PAD300-HD,PAD300-
PHD.
e PAD300-RB does not consume extra address on
the loop but is assigned a sub-address from the attached
detector. It does not require an auxiliary power source.
Each base includes one (1) LED which ashes
momentarily in normal and detector alarm conditions.
e LED can be turned o using the programming
soware.
For further information, please refer to the control panel
installation instructions.
Refer to the company website for the lastest revision of
this manual.
B. Specications
A. Introduction
C. Mounting
Mounting Options:
PAD300-RB can be mounted on a single gang, 3-1/2” octagon, 3-1/2”
square, double gang, 4” octagon, 4” square, 50mm c/c, 60mm c/c and
70mm c/c boxes.
Terminal Layout:
Mounting Instructions:
1. Loosen screws on junction box or leave screws in place.
2. Align keyholes on the mounting plate with screw heads.
3. Slide screws to the slot on the mounting plate.
4. Tighten screws to secure mounting plate.
5. Plug base and turn clockwise to secure in place.Tighten screws
to secure base on mounting plate.
Mounting plate
Screw
Relay Contacts:
NC/COM/NO
SLC+/SLC-
1609 Park 370 Pl, Hazelwood, MO 63042
www.pottersignal.com
Specications / Ratings for detector base only:
DETECTORS ARE NOT TO BE USED WITH
DETECTOR GUARDS UNLESS THE COMBINATION HAS BEEN
EVALUATED AND FOUND SUITABLE FOR THAT PURPOSE.
e device includes a tamperproof feature that locks the detector and
does not allow removal without the use of a tool.
POTTER warrants that the equipment herein shall conform
to said descriptions as to all armation of fact and shall be
free from defects of manufacture, labeling, and packaging for
a period of ve (5) years from the invoice date to the original
purchaser, provided that representative samples are returned
to POTTER for inspection. e product warranty period is
stated on the exterior of the product package. Upon a de-
termination by POTTER that a product is not as warranted,
POTTER shall, at its exclusive option, replace or repair said
defective product or parts thereof at its own expense, except
that Purchaser shall pay all shipping, insurance, and similar
charges incurred in connection with the replacement of the
defective product or parts thereof.
e product is not intended to be serviced in the eld. Return
to factory for servicing. is Warranty is void in the case of
abuse, misuse, abnormal usage, faulty installation, or repair
by unauthorized persons, or if for any other reason POTTER
determines that said product is not operating properly as a
result of causes other than defective manufacture, labeling, or
packaging.
F. Warranty
All terminals are power limited and should be wired in
accordance with the requirements of NFPA 70 (NEC) and
NFPA 72 (National Fire Alarm Code). Failure to follow the
wiring diagrams in the following pages will cause the system
to not operate as intended.
1. Before connecting a device to the SLC loop, take the
following precautions to prevent potential damage to the
SLC or device.
• Power to the SLC is removed.
• Field wiring on device is correctly installed on the base
(supplied separately). Beware of the polarity marked next
to the terminals. S+ is positive and S- is negative.
• Use wires between size 22 AWG to 12 AWG.
• Strip all wires 1/4 inch from their edges shown here:
• Field wiring has no open or short circuit.
2. Set the desired address using the DIP switch located on back
of the sensor. Refer to addressing instruction in the manual of
detector.
3. Plug sensor on base and turn clockwise to secure in place. Refer
to section E for detail of the locking feature.
e product may be installed as a Class B, Class A or Class X.
Class B Wiring:
D. Wiring Class A and X Wiring:
NOTE: THE BUILT-IN ISOLATION IN EACH PAD300 SERIES
DETECTOR CONFIGURED IN CLASS A WITH THE SOUNDER
BASE ALSO MAKES THE INSTALLATION A CLASS X.
NOTE: CLASS X REQUIRES A CLOSE NIPPLE OR CONDUIT
CONNECTION TO EVERY DEVICE.
E. Locking Feature
1/4 inch
DO NOT LOOP WIRE AROUND TERMINAL.
SEPARATE WIRES TO ALLOW FOR CONNECTION
SUPERVISION.
CAUTION
Break o tab (gray area in
image). e llocking featureocking feature
is enabled
Insert a small
screwdriver into slot
to remove detector.
UL COMPATIBLE FIRE ALARM PANEL
SLC-
SLC+
UL COMPATIBLE FIRE ALARM PANEL
SLC-
SLC-
SLC+
SLC+
Manual Number:
54035219X_A
Manual Issue Date:
07/01/2022

Other Potter Security Sensor manuals

Potter PAD300-CD User manual

Potter

Potter PAD300-CD User manual

Potter PAD200-DUCT User manual

Potter

Potter PAD200-DUCT User manual

Potter RA-6500R User manual

Potter

Potter RA-6500R User manual

Potter PAD100-IB User manual

Potter

Potter PAD100-IB User manual

Potter PAD300-4DB User manual

Potter

Potter PAD300-4DB User manual

Potter PAD100-RB User manual

Potter

Potter PAD100-RB User manual

Potter PAD300-DD User manual

Potter

Potter PAD300-DD User manual

Potter Amseco EBP-401 Quick start guide

Potter

Potter Amseco EBP-401 Quick start guide

Potter FEP-A Series User manual

Potter

Potter FEP-A Series User manual

Potter PAD100-DUCT User manual

Potter

Potter PAD100-DUCT User manual

Potter RA-6006 User manual

Potter

Potter RA-6006 User manual

Potter CS-24 Series User manual

Potter

Potter CS-24 Series User manual

Potter amseco SB24 Series User manual

Potter

Potter amseco SB24 Series User manual

Potter EVD-2 User manual

Potter

Potter EVD-2 User manual

Potter IDC-6 User manual

Potter

Potter IDC-6 User manual

Potter PAD300-HD User manual

Potter

Potter PAD300-HD User manual

Potter EVD-1 User manual

Potter

Potter EVD-1 User manual

Potter Amseco EBP-401 User manual

Potter

Potter Amseco EBP-401 User manual

Potter PAD100-PD User manual

Potter

Potter PAD100-PD User manual

Potter LFH-24 Series User manual

Potter

Potter LFH-24 Series User manual

Potter PAD300-IB User manual

Potter

Potter PAD300-IB User manual

Potter PAD100-DUCTR User manual

Potter

Potter PAD100-DUCTR User manual

Potter PAD100-LFSB User manual

Potter

Potter PAD100-LFSB User manual

Potter PAD300-SB User manual

Potter

Potter PAD300-SB User manual

Popular Security Sensor manuals by other brands

Infinite L-com SRCN-C410-3 user guide

Infinite

Infinite L-com SRCN-C410-3 user guide

MSA FireHawk M7 user manual

MSA

MSA FireHawk M7 user manual

Selcom Security NT-R user manual

Selcom Security

Selcom Security NT-R user manual

SWARCO Caiman Installation

SWARCO

SWARCO Caiman Installation

Tyco FV300 SERIES user manual

Tyco

Tyco FV300 SERIES user manual

Gas Clip Technologies Multi Gas Clip Simple user manual

Gas Clip Technologies

Gas Clip Technologies Multi Gas Clip Simple user manual

Respirex GLS 300 A User instructions

Respirex

Respirex GLS 300 A User instructions

Waters 3100 Operator's guide

Waters

Waters 3100 Operator's guide

Baumer URDK 10P8914/S35A quick start guide

Baumer

Baumer URDK 10P8914/S35A quick start guide

Omron F3S-TGR-SB2-KXC user manual

Omron

Omron F3S-TGR-SB2-KXC user manual

Antec Scientific FlexCell user manual

Antec Scientific

Antec Scientific FlexCell user manual

Honeywell SPM Flex user manual

Honeywell

Honeywell SPM Flex user manual

LEGRAND Mosaic 0 489 22 manual

LEGRAND

LEGRAND Mosaic 0 489 22 manual

ELRO FC451011 instruction manual

ELRO

ELRO FC451011 instruction manual

Greenlee FI-100 instruction manual

Greenlee

Greenlee FI-100 instruction manual

VOSS.farming FS10 instruction manual

VOSS.farming

VOSS.farming FS10 instruction manual

ELTEX UPG-Stitch instructions

ELTEX

ELTEX UPG-Stitch instructions

Honeywell ADEMCO 5808EU installation instructions

Honeywell

Honeywell ADEMCO 5808EU installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.