manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Potter
  6. •
  7. Security Sensor
  8. •
  9. Potter amseco SB24 Series User manual

Potter amseco SB24 Series User manual

This manual suits for next models

4

Other Potter Security Sensor manuals

Potter Amseco EBP-401 Quick start guide

Potter

Potter Amseco EBP-401 Quick start guide

Potter IDC-6 User manual

Potter

Potter IDC-6 User manual

Potter PAD100-DUCTR User manual

Potter

Potter PAD100-DUCTR User manual

Potter PAD300-HD User manual

Potter

Potter PAD300-HD User manual

Potter PAD200-DUCTR User manual

Potter

Potter PAD200-DUCTR User manual

Potter CS-24 Series User manual

Potter

Potter CS-24 Series User manual

Potter PAD300-SB User manual

Potter

Potter PAD300-SB User manual

Potter PAD300-IB User manual

Potter

Potter PAD300-IB User manual

Potter PAD300-4DB User manual

Potter

Potter PAD300-4DB User manual

Potter PAD300-CD User manual

Potter

Potter PAD300-CD User manual

Potter Amseco EBP-401 User manual

Potter

Potter Amseco EBP-401 User manual

Potter PAD200-DUCT User manual

Potter

Potter PAD200-DUCT User manual

Potter PAD100-PD User manual

Potter

Potter PAD100-PD User manual

Potter RA-6006 User manual

Potter

Potter RA-6006 User manual

Potter EVD-2 User manual

Potter

Potter EVD-2 User manual

Potter PAD100-RB User manual

Potter

Potter PAD100-RB User manual

Potter PAD300-DD User manual

Potter

Potter PAD300-DD User manual

Potter PAD300-RB User guide

Potter

Potter PAD300-RB User guide

Potter LFH-24 Series User manual

Potter

Potter LFH-24 Series User manual

Potter EVD-1 User manual

Potter

Potter EVD-1 User manual

Potter FEP-A Series User manual

Potter

Potter FEP-A Series User manual

Potter PAD100-DUCT User manual

Potter

Potter PAD100-DUCT User manual

Potter PAD100-LFSB User manual

Potter

Potter PAD100-LFSB User manual

Potter PAD100-IB User manual

Potter

Potter PAD100-IB User manual

Popular Security Sensor manuals by other brands

Honeywell Home PROSiXCOCN Installation and setup guide

Honeywell Home

Honeywell Home PROSiXCOCN Installation and setup guide

Duevi SIRPZ-RB-868 Operation

Duevi

Duevi SIRPZ-RB-868 Operation

RKI 65-2483RK Operator's manual

RKI

RKI 65-2483RK Operator's manual

Nortech PD160 Enhanced Series user manual

Nortech

Nortech PD160 Enhanced Series user manual

Omron K8AC-H2 manual

Omron

Omron K8AC-H2 manual

Agilent Technologies G8610 Series Quick reference card

Agilent Technologies

Agilent Technologies G8610 Series Quick reference card

Shinko SE2EA-1-0-0 instruction manual

Shinko

Shinko SE2EA-1-0-0 instruction manual

Det-Tronics X Series instructions

Det-Tronics

Det-Tronics X Series instructions

ACR Electronics COBHAM RCL-300A Product support manual

ACR Electronics

ACR Electronics COBHAM RCL-300A Product support manual

TOOLCRAFT 1712612 operating instructions

TOOLCRAFT

TOOLCRAFT 1712612 operating instructions

Elkron IM600 Installation, programming and functions manual

Elkron

Elkron IM600 Installation, programming and functions manual

Bosch WEU PDO 6 Original instructions

Bosch

Bosch WEU PDO 6 Original instructions

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

SB24 SERIES
SELECT-A-STROBE
Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.amseco-kai.com
MFG. #5401400 - REV B
9/07
PAGE 1 OF 2
PRINTED IN USA
A Brand
Model Number Stock Number Rated Voltage
(VDC)
Strobe Output
(cd) Sync Module
SB24-1530R 4560036 24 15 or 30 SMD10-3A
SB24-75110R 4560037 24 75 or 110 SMD10-3A
Engineering Specifications
The visual alarm indicating appliance shall be Amseco model SB24 Strobe Series or equivalent device. The strobe shall be listed under UL
1971 standard for signaling devices for the hearing impaired and shall be approved for fire protective service. The candela output shall be field
selectable, having a dual setting of 15/75 cd or 30/120 cd output. The signaling strobe shall operate on 24V DC from a non-coded regulated
DC supply or full-wave rectified, unfiltered supply. It is designed to produce a signal flash of one flash per second with continuously applied
minimum voltage. The strobe shall be capable of wall or ceiling mounting to an electrical back box. Visual signaling devices shall be mounted
to 80” above the highest floor point or 6” below ceiling, whichever is lowest. They are to be installed as per plans and specifications.
Ordering Information
• Strobe with two field selectable settings 15/30 and 75/110
• Designed to meet or exceed NFPA/ANSI standards and ADA
accessibility giodelines
• Polarized models with wide listed voltage ranges using filtered DC or
unfiltered FWR input voltage
• Flying leads for in/out wiring supervision
• All models mount to 4” square back box
• Available in 24VDC polarized models
• Strobe synchronization requires an Amseco SMD10-3A (daisy chain)
sync module
• Viewable candela setting
• Indoor/outdoor
Amseco’s newly designed UL1971 listed Select-A-Strobe Series SB24-153075 and SB24-75110 are designed to provide visual signaling devices
for fire protective systems. They meet UL 1638 standard for visual signaling devices for the hearing impaired, ADA requirements, ANSI and
NFPA standards.
The light output can be selected by a selector jumper (white) located on the front panel. Model SB24-153075 can be set for 15cd (jumper not
cut) or 30cd (jumper cut). The SB24-75110 can be set at 75cd (jumper not cut) or 110cd (jumper cut).
In those instances where two ore more Amseco chimes, horns, and/or strobes are connected and require a synchronized code 3 temporal pattern
and/or strobe flash, the Amseco SMD10-3A Sync Module (daisy chain) may be used to meet the required codes.
Wiring Diagram
Control
Panel
To Next
Device or
End-of-Line
Resistor
F.A.C.P.
Strobe
Signal
Circuit
Sync Module
SMD10-3A
Input Output
To Next
Device or
End-of-Line
Resistor
Wiring diagram for audible strobe Class”B” circuit.
WIRING 2
WIRING 1 Any combination of models
powered by a 2-wire circuit.
SB24-1530
SB24-75110
SB24-1530
SB24-75110
HH
Refer to the SMD10-3A Sync Module instruction manual for Class “A” wiring or other application diagrams.
firealarmresources.com
Installation
Dimensions: inches (mm)
4 1/64 (102)
4 1/64 (102)
FRONT VIEW SIDE VIEW BACK VIEW
2 7/64 (53.7) 3 3/8 (85.7)
3 3/8 (85.7)
10 5/8 (270)
How to remove the cover
Flat head screwdriver
Jumper
Select-A-Jumper
SB24-153075 SB24-75110
Not Cut 15cd 75cd
Cut 30cd 110cd
For stand alone installation:
1. Locate the locking tab at the center of the lowest louver on the
front cover.
2. Insert a small flat head screwdriver to the lift tab in order to release
the cover from the unit.
SB24-153075/75110
Adjuster
(Nylon Bushings)
#8-32
Screws
Nylon Bushings
Knockout Hole
BZ-54
BBX-4
Mounting
MFG. #5401400 - REV B
9/07
PAGE 2 OF 2
PRINTED IN USA
A Brand
SB24 SERIES
SELECT-A-STROBE
Light Output
Compound 45
Compound 45
Wall Mount - Horizontal Wall Mount - Vertical
Degrees
5-25
0
30
35
40
45
50
55
60
65
70
75
80
85-90
Compound 45
15cd 30cd 75cd 110cd 15cd 30cd 75cd 110cd
75.00 75.00 75.00 75.00 75.00 75.00110.00 110.00
13.50 27.00 67.50 99.00 13.50 27.00 67.50 99.00
11.25 22.50 56.25 82.50 13.50 27.00 67.50 99.00
11.25 22.50 56.25 82.50 9.75 19.50 48.75 71.50
11.25 22.50
22.5011.25
56.25 82.50 6.90 13.80 34.50 50.60
56.25 82.50 5.10 10.20 25.50 37.40
8.25 16.50 41.25 60.50 4.05 8.10 20.25 29.70
6.75 13.50 33.75 49.50 3.30 6.60 16.50 24.20
6.00 12.00 30.00 44.00 2.70 5.40 13.50 19.80
5.25 10.50 26.25 38.50 2.40 4.80 12.00 17.60
5.25 10.50 26.25 38.50 2.25 4.50 11.25 16.50
4.50 9.00 22.50 33.00 1.95 3.90 9.75 14.30
4.50 9.00 22.50 33.00 1.80 3.60 9.00 13.20
13.20
9.00
3.60
1.80
27.0018.757.50
3.75
26.4018.007.203.60
UL Required Minimum Light Output (cd)
For semi-flush mounting in combination with Amseco BZ-54 Horn:
1. Mount the SB24-153075/75110 to the horn with provided
accessory screws (#8-32 x 9/16” 14mm) by passing lead wires of the
SB24-153075/75110 through the nylon bushing wire hole of the horn.
2. Connect both lead wires of SB24-153075/75110 and BZ-54 to
the power supply from the control panel. Mount them together to
the back box (BBX-4 with the screws provided) into the strobe light
mounting holes.