PAD300-IB
SLC Voltage 24 VDC
SLC Standby / Alarm Current (*) 150 A
Active Current (LED ON) 4.5 mA
Installation Temp Range 32F to 150F
Operating Humidity Range 0% - 93% (Non-condensing)
Dimension Φ 6.4 in
Weight 6.88 oz
Height 1.57 in
*Standby current is the current the device consumes when the device
is in a non-activated condition and where no communication current
is transmitted to the re alarm control panel.
PAD300-IB
Contents
A. Introduction D. Wiring
B. Specications E. Locking Feature
C. Mounting F. Warranty
e PAD300-IB is an isolator base. It will open the
Signaling Line Circuit downstream when short circuit is
detected. is will provide devices between the control
panel and the isolator to continue to operate.
e PAD300-IB is a mounting base designed to work
specially with the PAD300 series detectors. Compatible
detectors include PAD300-PD, PAD300-HD,PAD300-
PHD.
Each base includes one (1) LED which is o in normal
condition. e short is indicated by a steady red LED
and once the short is removed the unit will return to
normal operation.
For further information, please refer to the control panel
installation instructions.
Refer to the company website for the latest revision of
this manual.
B. Specications
A. Introduction
C. Mounting
Mounting Options:
PAD300-IB can be mounted on a single gang, 3-1/2” octagon, 3-1/2”
square, double gang, 4” octagon, 4” square, 50mm c/c, 60mm c/c and
70mm c/c boxes.
Terminal Layout:
Mounting Instructions:
1. Loosen screws on junction box or leave screws in place.
2. Align keyholes on the mounting plate with screw heads.
3. Slide screws to the slot on the mounting plate.
4. Tighten screws to secure mounting plate.
5. Plug base and turn clockwise to secure in place.Tighten screws
to secure base on mounting plate.
Mounting plate
Screw
Isolation Contacts:
SLC2+/SLC2-
SLC+/SLC-
1609 Park 370 Pl, Hazelwood, MO 63042
www.pottersignal.com
Specications / Ratings for detector base only:
DETECTORS ARE NOT TO BE USED WITH
DETECTOR GUARDS UNLESS THE COMBINATION HAS BEEN
EVALUATED AND FOUND SUITABLE FOR THAT PURPOSE.
e device includes a tamperproof feature that locks the detector and
does not allow removal without the use of a tool.
POTTER warrants that the equipment herein shall conform to
said descriptions as to all armation of fact and shall be free from
defects of manufacture, labeling, and packaging for a period of ve
(5) years from the invoice date to the original purchaser, provided
that representative samples are returned to POTTER for inspection.
e product warranty period is stated on the exterior of the product
package. Upon a determination by POTTER that a product is not as
warranted, POTTER shall, at its exclusive option, replace or repair
said defective product or parts thereof at its own expense, except
that Purchaser shall pay all shipping, insurance, and similar charges
incurred in connection with the replacement of the defective product
or parts thereof.
e product is not intended to be serviced in the eld. Return to
factory for servicing. is Warranty is void in the case of abuse,
misuse, abnormal usage, faulty installation, or repair by unauthorized
persons, or if for any other reason POTTER determines that said
product is not operating properly as a result of causes other than
defective manufacture, labeling, or packaging.
F. Warranty
All terminals are power limited and should be wired in
accordance with the requirements of NFPA 70 (NEC) and
NFPA 72 (National Fire Alarm Code). Failure to follow the
wiring diagrams in the following pages will cause the system
to not operate as intended.
1. Before connecting a device to the SLC loop, take the
following precautions to prevent potential damage to the
SLC or device.
• Power to the SLC is removed.
• Field wiring on device is correctly installed on the base
(supplied separately). Beware of the polarity marked next
to the terminals. S+ is positive and S- is negative.
• Use wires between size 22 AWG to 12 AWG.
• Strip all wires 1/4 inch from their edges shown here:
• Field wiring has no open or short circuit.
2. Set the desired address using the DIP switch located on back
of the sensor. Refer to addressing instruction in the manual of
detector.
3. Plug sensor on base and turn clockwise to secure in place. Refer
to section E for detail of the locking feature.
e product may be installed as a Class B, Class A or Class X.
Class A Wiring:
D. Wiring Class B Wiring:
Class X Wiring:
E. Locking Feature
1/4 inch
DO NOT LOOP WIRE AROUND TERMINAL.
SEPARATE WIRES TO ALLOW FOR CONNECTION
SUPERVISION.
CAUTION
Break o tab (gray area in
image). e locking feature is
enabled
Insert a small
screwdriver into slot
to remove detector.
UL COMPATIBLE FIRE ALARM PANEL
SLC-
SLC-
SLC+
SLC+
Multiple Addressable Detector
SLC-
SLC+
UL COMPATIBLE FIRE ALARM PANEL
Detector
Detector
Single Addressable Detector
UL COMPATIBLE FIRE ALARM PANEL
SLC-
SLC-
SLC+
SLC+
NOTE: CLASS X REQUIRES A CLOSE NIPPLE OR CONDUIT
CONNECTION TO EVERY DEVICE.
Manual Number:
54035218X_A
Manual Issue Date:
07/01/2022

Other Potter Security Sensor manuals

Potter PAD100-DUCT User manual

Potter

Potter PAD100-DUCT User manual

Potter EVD-2 User manual

Potter

Potter EVD-2 User manual

Potter PAD100-DUCTR User manual

Potter

Potter PAD100-DUCTR User manual

Potter EVD-1 User manual

Potter

Potter EVD-1 User manual

Potter FEP-A Series User manual

Potter

Potter FEP-A Series User manual

Potter CS-24 Series User manual

Potter

Potter CS-24 Series User manual

Potter LFH-24 Series User manual

Potter

Potter LFH-24 Series User manual

Potter Amseco EBP-401 Quick start guide

Potter

Potter Amseco EBP-401 Quick start guide

Potter RA-6006 User manual

Potter

Potter RA-6006 User manual

Potter PAD100-RB User manual

Potter

Potter PAD100-RB User manual

Potter Amseco EBP-401 User manual

Potter

Potter Amseco EBP-401 User manual

Potter RA-6500R User manual

Potter

Potter RA-6500R User manual

Potter IDC-6 User manual

Potter

Potter IDC-6 User manual

Potter PAD100-PD User manual

Potter

Potter PAD100-PD User manual

Potter PAD300-HD User manual

Potter

Potter PAD300-HD User manual

Potter PAD300-RB User guide

Potter

Potter PAD300-RB User guide

Potter PAD300-4DB User manual

Potter

Potter PAD300-4DB User manual

Potter PAD300-DD User manual

Potter

Potter PAD300-DD User manual

Potter PAD100-IB User manual

Potter

Potter PAD100-IB User manual

Potter PAD200-DUCT User manual

Potter

Potter PAD200-DUCT User manual

Potter PAD300-CD User manual

Potter

Potter PAD300-CD User manual

Potter PAD100-LFSB User manual

Potter

Potter PAD100-LFSB User manual

Potter PAD300-SB User manual

Potter

Potter PAD300-SB User manual

Potter PAD200-DUCTR User manual

Potter

Potter PAD200-DUCTR User manual

Popular Security Sensor manuals by other brands

AJAX FireProtect 2 Heat/CO Jeweller manual

AJAX

AJAX FireProtect 2 Heat/CO Jeweller manual

2gig Technologies pir1-345 Installation instruction

2gig Technologies

2gig Technologies pir1-345 Installation instruction

Clas Ohlson EZ-8B quick start guide

Clas Ohlson

Clas Ohlson EZ-8B quick start guide

WITTUR CSGB-01 operating instructions

WITTUR

WITTUR CSGB-01 operating instructions

Panasonic KX-HNS104EX installation guide

Panasonic

Panasonic KX-HNS104EX installation guide

tau TAU-AC-900-PIVOT installation guide

tau

tau TAU-AC-900-PIVOT installation guide

RKI 35-3001A-01H Operator's manual

RKI

RKI 35-3001A-01H Operator's manual

Interlogix VE1012 Series Installation sheet

Interlogix

Interlogix VE1012 Series Installation sheet

Z-Wave SM103 manual

Z-Wave

Z-Wave SM103 manual

SPX Radiodetection RD8200 user guide

SPX

SPX Radiodetection RD8200 user guide

abi SENTRY Operator's manual

abi

abi SENTRY Operator's manual

NOHMI PDCJ001-D quick start guide

NOHMI

NOHMI PDCJ001-D quick start guide

Saxby Lighting 95283 instruction manual

Saxby Lighting

Saxby Lighting 95283 instruction manual

Radon Eye RD200 user manual

Radon Eye

Radon Eye RD200 user manual

DANLERS CBU-HBSP Installation

DANLERS

DANLERS CBU-HBSP Installation

DINUY DM TEC 011 instruction manual

DINUY

DINUY DM TEC 011 instruction manual

GFA FG 40-31,75 Ex installation instructions

GFA

GFA FG 40-31,75 Ex installation instructions

Sensit HXG-3P instruction manual

Sensit

Sensit HXG-3P instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.