Prexiso P100LCU User manual

IMPORTANT: Read before Using
P100LCU
®
LASER DISTANCE MEASURE
www.prexiso-eu.com
2WARRANTY
LIMITED
YEARS
FUNC

1
EN
Table of Contents
Instrument Set-up ------------------------------ 2
Overview---------------------------------------------
Display---------------------------------------------------
Insert batteries ----------------------------------------
2
2
2
Operations ---------------------------------------- 3
Switching ON/OFF -----------------------------------
Unitsetting Change ----------------------------------
Measurement Reference --------------------------
3
3
3
Functions ----------------------------------------- 4
Measuring single distance------------------------
Continuous measuring------------------------------
Modes---------------------------------------------------
Area------------------------------------------------------
Volume--------------------------------------------------
Pythagoras---------------------------------------------
Clear-----------------------------------------------------
Addition/Subtraction ---------------------------------
Angle Measurement ---------------------------------
Memory--------------------------------------------------
Bluetooth------------------------------------------------
Bluetooth Connection and Operation-----------
Brightness----------------------------------------------
4
4
4
5
5
6
7
8
8
9
9
10
10
Technical Data ---------------------------------
Message Codes -------------------------------
Care -----------------------------------------------
Disposal -----------------------------------------
11
11
11
11
Safety Instructions ----------------------------
Warranty -------------------------------------------
Symbols used -----------------------------------------
Permitted use -----------------------------------------
Prohibited use ----------------------------------------
Hazards in use ---------------------------------------
Limits of use ------------------------------------------
Areas of responsibility -----------------------------
Electromagnetic Compatibility (EMC) ----------
FCC statement (applicable in U.S.) -------------
Laser classification ----------------------------------
12
14
12
12
12
12
12
13
13
13
14
Prexiso P100LCU

Instrument Set-up
Overview
The safety instructions and the user manual should be
read through carefully before the product is used for the
first time.
The person responsible for the product must ensure that
all users understand these directions and adhere to them.
Display
Insert batteries
i
Change
batteries when
battery symbol
is empty.
Prexiso P100LCU
2
EN
FUNC
On / Measure /
Continuous
measuring
Units /
Measuring
Reference
Add/Sub
Bluetooth/
Area/Volume/
Pythagoras/
Brightness/
Memory
Clear / Off
Color Display
+
+-
-
Battery
Units
Main line
Info
Measuring
Reference
Memory
Bluetooth
Area/
Volume/
Pythagoras
88.8°
30

3
EN
Operations
Switching ON / OFF
ON OFF
Device is turned
OFF.
3 sec
3 sec
i
If no key is
pressed for
120 sec, the
device
switches off
automatically.
If the info icon appears with a number, observe the
instructions in section "Message Codes".
Example:
Unit setting
Switch between
the following units:
Prexiso P100LCU
CLEAR
OFF
Change the measurement reference
1 2
The system
default
measurements
start at the
bottom as a
reference point.
Press button
to change the
reference to
middle for
measurement.
3
Press button
to change the
reference to
top for
measurement.
0.000 m
0'00'' 1/16
0 1/16 in
0.00 ft

4
EN
Functions
Measuring single distance
1
Aim active laser at target
2 3
i
Target surfaces: Measuring errors can occur
when measuring to colourless liquids, glass,
styrofoam or semi-permeable surfaces or when
aiming at hight gloss surfaces. Against dark
surfaces the measuring time increases.
Continuous measuring
3 sec
1 2
The largest and smallest
measured value appear
above it
Stops continuous
measuring
Press button to start
the mode selected
43
Modes
21
Prexiso P100LCU
Aim active laser at target.
Press button to select
mode clockwise
Press button to select
mode counterclockwise
min max
59'99"
7
/
16
max
59'99"
7
/
16
min
19'99"
7
/
16
FUNC 3FUNC 4

Volume
1 2
Aim laser at
first target
point.
3 4
Aim laser at
second target
point.
5
Aim laser at
third target
point.
6
Modes
Prexiso P100LCU
Area
1 2
Aim laser at first
target point.
3 4
Aim laser at
second target
point.
24.352 ft
2
5
i
The result is shown in the
main line and the measured
distance above.
i
Note:
1. The system default measurement start at the single distance measuring.
2. Bluetooth and Brightness are inside of the ICON " "
3. The selection of specific Pythagoras, Bluetooth, Brightness and etc., is the same
way of modes seletion by clockwise or counterclockwise.
5
EN

78.694 ft
3
7
i
The result is shown in the main
line and the measured distance
above.
Prexiso P100LCU
90° 90°
Pythagoras
1 2
Aim laser
at first
target
point.
3
Aim laser at
second target
point(Perpen-
dicular to the
measuring
surface).
90°
4
Aim laser
at third target
point.
5
The result is shown in
the main line and the
measured distance
above.
Aim laser at
first target
point.
Aim laser at
second target
point.
Pythagoras
90°
1 2 3 4
The result is
shown in the
main line and
the measured
distance
above.
90°
59'99"
7
/
16
59'99"
7
/
16
6
EN

Prexiso P100LCU
Clear
1
Press button to
undo last action.
CLEAR
OFF
Aim laser at
target point.
Pythagoras
90°
1 2 3
The result is shown in the
main line and the measured
distance and angle above.
59'99"
7
/
16
90°
Pythagoras
1 2
Aim laser
at first target
point.
3
Aim laser at
second target
point
4
Aim laser
at third target
point.
(Perpendicular to the
measuring surface).
5
The result is shown in
the main line and the
measured distance
above.
59'99"
7
/
16
90° 90°
α
α
88.8°
EN
7

20’00
"
4
The result is
shown in the
main line and
the measured
distance
above.
1
Measure
the first
data.
3
Then
measure
the
second
data.
20'00"
Addition/subtraction
2
Press button once to add or
press button twice
to subtract next
measurement
from the previous
data.
or
EN
Prexiso P100LCU
8
The result is shown at the top of the
screen. Range: 0°-360° (4x90°)
Inclination measurement is
used to measure a slope or
incline (e. g stairs, railings,
when fitting furniture, laying
pipes, etc. )
Angle Measurement
1 2
ON
3
40.8
º
36.0
º
59'99"
7
/
16
79'99"
7
/
16
20’00
"
39'99"
7
/
16

i
CLEAR
OFF
Prexiso P100LCU
Memory
1
The last 30
measurements
are automatically
stored.
i
Delete the
memory.
i
Connect to the mobile devices
which have PREXISO app
installed in advance.
i
Search PREXISO app on App
Store or Google Play Store,
select and download the app
EN
9
30
88.8°
59'99"
7
/
16
59'99"
7
/
16
2
30
88.8°
59'99"
7
/
16
59'99"
7
/
16
Bluetooth
Install PREXISO app
1
Up towards the memory
Down towards the
memory
Step 1 and Step 2 are all available
for the following buttons
2

EN
Prexiso P100LCU
10
* Turn on the laser distance measure and the Bluetooth.
* Open the PREXISO app on your mobile device.
* Click the ICON "..." in the top right corner of the app to
follow the User Guide for operation.
Bluetooth Connection and Operation
FUNC
i
To select different brightness of
the screen.
Brightness
1 2 3
OR

11
EN
Technical Data
*The typical measurement uncertainty of ± 2 mm
is valid for measurements on white, diffusive,
reflective targets up to 5 m at low ambient light
and moderate temperatures. For distances
greater than 5 m, the measurement uncertainty
could increase additionally by 0.1 mm/m. In
unfavourable conditions (such as bright sunlight,
targets with poor reflectivity, or high or low
temperatures) the measurement uncertainty
could further increase up to ± 4 mm for distances
below 5 m and additionally by roughly 0.15
mm/m for distances greater than 5 m.
Message Codes
If the message Error does not disappear after
switching on the device repeatedly, contact the
dealer.
If the message InFo appears with a number,
press the Clear button and observe the
following instructions:
Care
• Clean the device with a damp, soft cloth.
• Never immerse the device in water.
• Never use aggressive cleaning agents or
solvents.
Disposal
CAUTION
Flat batteries must not be disposed
of with household waste. Care for
the environment and take them to
the collection points provided in
accordance with national or local
regulations. The product must not
be disposed with household waste.
Dispose of the product
appropriately in accordance
with the national regulations in
force in your country. Adhere to
the national and country specific
regulations. Product specific
treatment and waste management
can be downloaded from our
homepage.
General
Range 0.09 - 100 m
0.29 - 330 ft
Measuring accuracy* ± 2 mm
± 3/32 in
Smallest unit displayed 1 mm
1/16 in
Laser class
Laser type
Degree of Protection:
Autom. power switch-off
Continuous measuring
Area / Volume
Dimension(LxWxH)
2
635 nm, < 1 mW
after 120 s
yes
yes
Battery durability (2 x AAA) up to 3000
measurements
Weight
(without batteries)
Temperature range:
- Storage
- Operation
-10 to 60 °C
14 to 140 °F
0 to 40 °C
32 to 104 °F
Prexiso P100LCU
120 x 45 x 24 mm
4.7 x 1.8 x 0.9 in
81 g / 2.86 oz
No. Cause Correction
IP54
101 The battery is out
of power
204 Measuring error
252 Temperature too high
253 Temperature too low
254 Out of measuring range
255 Received signal too
weak, measuring time
too long or outside of
measuring range
256 Received signal too high
257 Too much background
light
294 The results out of
maximal digit on screen
280 Module error
224 Hardware failure
Change batteries
Restart measuring
Let device cool down.
Warm device up.
Correct range
Change target surface
(e.g. white paper) or
correct range.
Change target surface
(e.g. white paper).
Shadow target area.
Get the results by
changing units or calculate
manually
Restart the device
Contact the dealer

EN
Safety Instructions
The person responsible for the instrument
must ensure that all users understand
these directions and adhere to them.
Symbols used
The symbols used have the following
meanings:
WARNING
Indicates a potentially hazardous situation
or an unintended use which, if not avoided,
will result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation
or an unintended use which, if not avoided,
may result in minor injury and/or
appreciable material, financial and
environmental damage.
Important paragraphs which must be
adhered to in practice as they enable
the product to be used in a technically
correct and efficient manner.
Permitted use
• Measuring distances
Prohibited use
• Using the product without instruction
• Using outside the stated limits
• Deactivation of safety systems and
removal of explanatory and hazard
labels
• Opening of the equipment by using tools
(screwdrivers, etc.)
• Carrying out modification or conversion
of the product
• Use of accessories from other
manufacturers without express approval
• Deliberate dazzling of third parties; also
in the dark
• Inadequate safeguards at the surveying
site (e.g. when measuring on roads,
construction sites, etc.)
• Deliberate or irresponsible behaviour on
scaffolding, when using ladders, when
measuring near machines which are
running or near parts of machines or
installations which are unprotected
• Aiming directly in the sun
Hazards in use
WARNING
Watch out for erroneous measurements if
the instrument is defective or if it has been
dropped or has been misused or modified.
Carry out periodic test measurements.
Particularly after the instrument has been
subject to abnormal use, and before,
during and after important measurements.
CAUTION
Never attempt to repair the product
yourself. In case of damage, contact a
local dealer.
WARNING
Changes or modifications not expressly
approved could void the user’s authority
to operate the equipment.
Limits of use
Refer to section "Technical data".
The device is designed for use in
areas permanently habitable by humans.
Do not use the product in explosion
hazardous areas or in aggressive
environments.
i
Prexiso P100LCU
12

Safety Instructions
13
EN
Areas of responsibility
Responsibilities of the person in
charge of the instrument:
• To understand the safety instructions
on the product and the instructions in
the User Manual.
• To be familiar with local safety
regulations relating to accident
prevention.
• Always prevent access to the product
by unauthorised personnel.
Electromagnetic Compatibility
(EMC)
WARNING
The device conforms to the most
stringent requirements of the relevant
standards and regulations. However,
the possibility of causing interference
in other devices cannot be totally
excluded.
This equipment has been tested and
found to comply with the limits for a Class
B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to
provide reasonable protection against
harmful interference in a residential
instal-lation.This equipment generates,
uses and can radiate radio frequency
energy and, if not installed and used in
accordance with the instructions, may
cause harmful interference to radio
communications.
However, there is no guarantee that
inter-ference will not occur in a particular
instal-lation. If this equipment does cause
harmful interference to radio or television
reception, which can be determined by
turning the equipment off and on, the user
is encouraged to try to correct the
interference by one or more of the
following measures:
• Reorient or relocate the receiving
antenna.
• Increase the separation between the
equipment and receiver.
• Connect the equipment into an outlet
on a circuit different from that to which
the receiver is connected.
• Consult the dealer or an experienced
radio/TV technician for help.
Prexiso P100LCU
FCC statement (applicable in U.S.)

EN
The device produces visible laser beams, which are emitted from the
instrument: It is a Class 2 laser product in accordance with:
Do not stare into the laser beam or direct it towards other people
unnecessarily. Eye protection is normally afforded by aversion
responses including the blink reflex.
Laser Class 2 products:
IEC60825-1 : 2014“Radiation safety of
laser products”
WARNING
Looking directly into the beam with optical aids
(e.g. binoculars, telescopes) can be hazardous.
WARRANTY
The Prexiso P100LCU has a two-year warranty.
For further information on this, contact your dealer.
This warranty is void if product is used for
commercial purposes. This warranty is not
transferable and does not cover products
damaged by misuse, neglect, accident,
alterations or use and maintenance other than
that specified in the owner's manual. This
warranty does not apply to any expendable
parts that can wear from normal use. This
warranty excludes any accessories.
Labelling
Subject to change (drawings, descriptions and
technical data) without prior notice.
Prexiso P100LCU
Safety Instructions
Laser classification
14
Batteries: 2 x AAA
www.prexiso-eu.com
FL-SIG
P100LCU
Complies with 21 CFR 1040.10 and 1040.11
except for deviations pursuant to Laser Notice
No.50, dated June 24, 2007
IEC/EN 60825-1:2014 λ=635nm Pav.=0.95mW tp=>400ps
Table of contents
Other Prexiso Analytical Instrument manuals
Popular Analytical Instrument manuals by other brands

Swann
Swann AMU-II Installation instruction

ENERGY SUPPORT CORPORATION
ENERGY SUPPORT CORPORATION DTF-201 Operation manual

Teledyne
Teledyne 318R operating instructions

NXP Semiconductors
NXP Semiconductors KIT-TPLSNIFEVB user manual

Centech
Centech 67980 Set up and operating instructions

Delta
Delta SPY-CAM-6 user manual