Promise VessRAID 1740s User manual

VessRAID
1740s,1840s
ProductManual
Version 1.0

VessRAID 1740s, 1840s Product Manual
ii
Copyright
© 2009 Promise Technology, Inc. All Rights Reserved.
Copyright by Promise Technology, Inc. (Promise Technology). No part of this
manual may be reproduced or transmitted in any form without the expressed,
written permission of Promise Technology.
Trademarks
Promise, and the Promise logo are registered in U.S. Patent and Trademark
Office. All other product names mentioned herein may be trademarks or
registered trademarks of their respective companies.
Important data protection information
You should back up all data before installing any drive controller or storage
peripheral. Promise Technology is not responsible for any loss of data resulting
from the use, disuse or misuse of this or any other Promise Technology product.
Notice
Although Promise Technology has attempted to ensure the accuracy of the
content of this manual, it is possible that this document may contain technical
inaccuracies, typographical, or other errors. Promise Technology assumes no
liability for any error in this publication, and for damages, whether direct, indirect,
incidental, consequential or otherwise, that may result from such error, including,
but not limited to loss of data or profits.
Promise Technology provides this publication “as is” without warranty of any kind,
either express or implied, including, but not limited to implied warranties of
merchantability or fitness for a particular purpose.
The published information in the manual is subject to change without notice.
Promise Technology reserves the right to make changes in the product design,
layout, and driver revisions without notification to its users.
This version of the Product Manual supersedes all previous versions.
Recommendations
In this Product Manual, the appearance of products made by other companies,
including but not limited to software, servers, and disk drives, is for the purpose of
illustration and explanation only. Promise Technology does not recommend,
endorse, prefer, or support any product made by another manufacturer.

iii
Contents
Chapter 1: Introduction to VessRAID . . . . . . . . . . . . . . . . . . . . . . . . . .1
About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
VessRAID Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Architectural Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Highlights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Subsystem and Controller Features . . . . . . . . . . . . . . . . . . . . . .4
Operational Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Warranty and Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
CE Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
FCC Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
KCC Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Chapter 2: VessRAID Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Unpacking the VessRAID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Installing the LCD Panel (Optional) . . . . . . . . . . . . . . . . . . . . . . . . .11
Mounting VessRAID in a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Installing Disk Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Drive Slot Numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Installing Your Disk Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Making Data and Management Connections . . . . . . . . . . . . . . . . .17
Configuring a Data Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Configuring a Management Path . . . . . . . . . . . . . . . . . . . . . . .17
Setting Up Serial Cable Connections . . . . . . . . . . . . . . . . . . . . . . .19
Connecting the Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Front Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Controller LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Disk Drive LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
LCD Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Chapter 3: VessRAID Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Setting up the Serial Connection . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Choosing DHCP or a Static IP Address . . . . . . . . . . . . . . . . . . . . .24
Setting up with the CLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

VessRAID 1740s, 1840s Product Manual
iv
Chapter 3: VessRAID Setup, cont.
Setting up with the CLU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Setting system date and time . . . . . . . . . . . . . . . . . . . . . . . . . .26
Making Manual IP Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Making Automatic IP Settings . . . . . . . . . . . . . . . . . . . . . . . . . .27
Viewing IP Address and Settings . . . . . . . . . . . . . . . . . . . . . . .27
Exiting the CLU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Setting up with the LCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Making Manual IP Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Making Automatic IP Settings . . . . . . . . . . . . . . . . . . . . . . . . . .29
Creating Disk Arrays with WebPAM PROe . . . . . . . . . . . . . . . . . . .30
Logging into WebPAM PROe . . . . . . . . . . . . . . . . . . . . . . . . . .30
Selecting a Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Creating a Disk Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Logging out of WebPAM PROe . . . . . . . . . . . . . . . . . . . . . . . .36
Using WebPAM PROe over the Internet . . . . . . . . . . . . . . . . . .37
Obtaining a Security Certificate . . . . . . . . . . . . . . . . . . . . . . . .37
Chapter 4: Management with WebPAM PROe . . . . . . . . . . . . . . . . . .39
Logging into WebPAM PROe . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Selecting a Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
Perusing the Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Using the Header . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
Using Tree View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
Using Management View . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
Viewing the Event Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
Logging out of WebPAM PROe . . . . . . . . . . . . . . . . . . . . . . . .46
Working with the Storage Network . . . . . . . . . . . . . . . . . . . . . . . . .47
Viewing Other Subsytems . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Updating the List of Subsystems . . . . . . . . . . . . . . . . . . . . . . .47
Logging into a Subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Hiding the Other Subsystems . . . . . . . . . . . . . . . . . . . . . . . . . .47
Working with Subsystems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
Viewing Subsystem Information . . . . . . . . . . . . . . . . . . . . . . . .48
Saving System Service Report . . . . . . . . . . . . . . . . . . . . . . . . .48
Setting an Alias for the Subsystem . . . . . . . . . . . . . . . . . . . . . .49
Setting Subsystem Date and Time . . . . . . . . . . . . . . . . . . . . . .49
Viewing the Runtime Event Log . . . . . . . . . . . . . . . . . . . . . . . .49
Saving the Runtime Event Log . . . . . . . . . . . . . . . . . . . . . . . . .50
Clearing the Runtime Event Log . . . . . . . . . . . . . . . . . . . . . . . .50

Contents
v
Chapter 4: Management with WebPAM PROe, cont.
Working with Subsystems, cont.
Viewing NVRAM Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Saving NVRAM Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
Clearing NVRAM Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
Viewing Current Background Activities . . . . . . . . . . . . . . . . . . .52
Making Background Activity Settings . . . . . . . . . . . . . . . . . . . .52
Running Background Activities . . . . . . . . . . . . . . . . . . . . . . . . .53
Running Media Patrol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
Running PDM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
Viewing Scheduled Activities . . . . . . . . . . . . . . . . . . . . . . . . . .54
Scheduling an Activity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
Deleting a Scheduled Activity . . . . . . . . . . . . . . . . . . . . . . . . . .55
Viewing Lock Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Setting the Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Renewing the Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Releasing the Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
Managing Users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
Viewing User Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
Making User Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
Making Your Own User Settings . . . . . . . . . . . . . . . . . . . . . . . .59
Setting-up User Event Subscriptions . . . . . . . . . . . . . . . . . . . .59
Changing Another User’s Password . . . . . . . . . . . . . . . . . . . . .60
Changing Your Own Password . . . . . . . . . . . . . . . . . . . . . . . . .60
Creating a User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
Deleting a User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
Viewing User Sessions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
Logging out Other Users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
Managing the Network Connection . . . . . . . . . . . . . . . . . . . . . . . . .63
Making Management Port Settings . . . . . . . . . . . . . . . . . . . . . .63
Managing SAS Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Viewing SAS Port Information . . . . . . . . . . . . . . . . . . . . . . . . . .64
Making SAS Port Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Viewing SAS Port Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . .65
Viewing SAS Initiators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
Managing Storage Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
Adding an Initiator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
Deleting an Initiator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
Viewing the LUN Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Enabling LUN Masking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67

VessRAID 1740s, 1840s Product Manual
vi
Chapter 4: Management with WebPAM PROe, cont.
Managing Storage Services, cont.
Adding a LUN Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Editing a LUN Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Managing Software Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69
Making Email Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69
Making SLP Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
Making Web Server Settings . . . . . . . . . . . . . . . . . . . . . . . . . .71
Making Telnet Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
Making SNMP Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
Making Netsend Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74
Exporting the User Database . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76
Importing a User Database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76
Importing a Configuration Script . . . . . . . . . . . . . . . . . . . . . . . . . . .77
Updating the Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
Viewing Flash Image Information . . . . . . . . . . . . . . . . . . . . . . . . . .78
Restoring Factory Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79
Clearing Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79
Shutting Down the Subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . .80
Monitoring the Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80
Restarting the Subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81
Monitoring the Restart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81
Managing the Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82
Viewing the Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82
Viewing Controller Information . . . . . . . . . . . . . . . . . . . . . . . . .82
Viewing Controller Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . .83
Making Controller Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . .83
Clearing an Orphan Watermark . . . . . . . . . . . . . . . . . . . . . . . .84
Managing Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86
Viewing the Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86
Locating an Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86
Viewing Enclosure Topology . . . . . . . . . . . . . . . . . . . . . . . . . . .87
Viewing Enclosure Information . . . . . . . . . . . . . . . . . . . . . . . . .88
Making Enclosure Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
Viewing FRU VPD Information . . . . . . . . . . . . . . . . . . . . . . . . .88
Checking the Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89
Reconditioning a Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90
Silencing the Buzzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90
Making Buzzer Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90
Testing the Buzzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91

Contents
vii
Chapter 4: Management with WebPAM PROe, cont.
Managing Physical Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92
Viewing a List of Physical Drives . . . . . . . . . . . . . . . . . . . . . . .92
Identifying a Physical Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . .92
Making Global Physical Drive Settings . . . . . . . . . . . . . . . . . . .93
Viewing Physical Drive Information . . . . . . . . . . . . . . . . . . . . . .93
Viewing Physical Drive Statistics . . . . . . . . . . . . . . . . . . . . . . .94
Making Physical Drive Settings . . . . . . . . . . . . . . . . . . . . . . . . .94
Clearing Stale and PFA Conditions . . . . . . . . . . . . . . . . . . . . .95
Forcing a Physical Drive Offline or Online . . . . . . . . . . . . . . . .96
Locating a Physical Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96
Managing Disk Arrays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .98
Viewing Disk Arrays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .98
Creating a Disk Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .98
Creating a Disk Array – Automatic . . . . . . . . . . . . . . . . . . . . . .99
Creating a Disk Array – Express . . . . . . . . . . . . . . . . . . . . . . .100
Creating a Disk Array – Advanced . . . . . . . . . . . . . . . . . . . . .101
Deleting a Disk Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103
Viewing Disk Array Information . . . . . . . . . . . . . . . . . . . . . . . .103
Making Disk Array Settings . . . . . . . . . . . . . . . . . . . . . . . . . . .104
Creating a Logical Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . .105
Deleting a Logical Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106
Migrating a Disk Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106
Rebuilding a Disk Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107
Running Media Patrol on a Disk Array . . . . . . . . . . . . . . . . . .108
Running PDM on a Disk Array . . . . . . . . . . . . . . . . . . . . . . . .109
Transitioning a Disk Array . . . . . . . . . . . . . . . . . . . . . . . . . . . .109
Preparing a Disk Array for Transport . . . . . . . . . . . . . . . . . . .110
Managing Logical Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111
Viewing Information for All Logical Drives . . . . . . . . . . . . . . . .111
Viewing Logical Drive Information . . . . . . . . . . . . . . . . . . . . . .112
Viewing Logical Drive Statistics . . . . . . . . . . . . . . . . . . . . . . .113
Making Logical Drive Settings . . . . . . . . . . . . . . . . . . . . . . . . .113
Initializing a Logical Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . .113
Running Redundancy Check . . . . . . . . . . . . . . . . . . . . . . . . .114
Viewing the Logical Drive Check Table . . . . . . . . . . . . . . . . .115
Making Logical Drive LUN Settings . . . . . . . . . . . . . . . . . . . .116

VessRAID 1740s, 1840s Product Manual
viii
Chapter 4: Management with WebPAM PROe, cont.
Managing Spare Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .117
Viewing a List of Spare Drives . . . . . . . . . . . . . . . . . . . . . . . .117
Locating a Spare Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .117
Creating a Spare Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118
Deleting Spare Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .119
Making Spare Drive Settings . . . . . . . . . . . . . . . . . . . . . . . . .119
Running Spare Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120
Working with the Logical Drive Summary . . . . . . . . . . . . . . . . . . .121
Viewing a List of All Logical Drives . . . . . . . . . . . . . . . . . . . . .121
Viewing Individual Logical Drive Information . . . . . . . . . . . . .121
Chapter 5: Management with the CLU . . . . . . . . . . . . . . . . . . . . . . .123
Logging into the CLU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .124
Making a Serial Connection . . . . . . . . . . . . . . . . . . . . . . . . . .124
Making a Telnet Connection . . . . . . . . . . . . . . . . . . . . . . . . . .124
Accessing Online Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126
Logging out of the CLU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126
Running Quick Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126
Managing the Subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127
Setting an Alias for the Subsystem . . . . . . . . . . . . . . . . . . . . .127
Running Media Patrol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127
Locking or Unlocking the Subsystem . . . . . . . . . . . . . . . . . . .127
Setting Subsystem Date and Time . . . . . . . . . . . . . . . . . . . . .128
Managing the Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129
Viewing Controller Information . . . . . . . . . . . . . . . . . . . . . . . .129
Clearing an Orphan Watermark . . . . . . . . . . . . . . . . . . . . . . .129
Making Controller Settings . . . . . . . . . . . . . . . . . . . . . . . . . . .129
Locating the Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130
Managing the Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132
Viewing Enclosure Information . . . . . . . . . . . . . . . . . . . . . . . .132
Viewing Power Supply Status . . . . . . . . . . . . . . . . . . . . . . . . .132
Locating a Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . .133
Viewing Cooling Unit Status . . . . . . . . . . . . . . . . . . . . . . . . . .133
Viewing Voltage Sensor Status . . . . . . . . . . . . . . . . . . . . . . . .133
Viewing Temperature Sensor Status . . . . . . . . . . . . . . . . . . .133
Setting Temperature Thresholds . . . . . . . . . . . . . . . . . . . . . .134
Checking the Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134
Reconditioning a Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . .135
Locating an Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .135
Viewing Enclosure Topology . . . . . . . . . . . . . . . . . . . . . . . . . .136

Contents
ix
Chapter 5: Management with the CLU, cont.
Managing Physical Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .137
Making Global Physical Drive Settings . . . . . . . . . . . . . . . . . .137
Setting an Alias . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138
Viewing Advanced Information . . . . . . . . . . . . . . . . . . . . . . . .138
Viewing Physical Drive Statistics . . . . . . . . . . . . . . . . . . . . . .138
Clearing Stale and PFA Conditions . . . . . . . . . . . . . . . . . . . .138
Forcing a Physical Drive Offline or Online . . . . . . . . . . . . . . .139
Locating a Physical Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
Managing Disk Arrays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .140
Creating a Disk Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .140
Creating a Disk Array – Automatic . . . . . . . . . . . . . . . . . . . . .141
Creating a Disk Array – Express . . . . . . . . . . . . . . . . . . . . . . .142
Creating a Disk Array – Advanced . . . . . . . . . . . . . . . . . . . . .143
Deleting a Disk Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144
Viewing Disk Array Information . . . . . . . . . . . . . . . . . . . . . . . .144
Setting an Alias for a Disk Array . . . . . . . . . . . . . . . . . . . . . . .145
Accepting an Incomplete Array . . . . . . . . . . . . . . . . . . . . . . . .145
Enabling Media Patrol on a Disk Array . . . . . . . . . . . . . . . . . .146
Enabling PDM on a Disk Array . . . . . . . . . . . . . . . . . . . . . . . .146
Preparing the Disk Array for Transport . . . . . . . . . . . . . . . . . .146
Rebuilding a Disk Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . .146
Migrating a Disk Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .147
Running PDM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148
Running Transition on a Disk Array . . . . . . . . . . . . . . . . . . . .148
Locating a Disk Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148
Creating a Logical Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149
Deleting a Logical Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150
Managing Spare Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .151
Viewing a list of Spare Drives . . . . . . . . . . . . . . . . . . . . . . . . .151
Creating a Spare Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .151
Making Spare Drive Settings . . . . . . . . . . . . . . . . . . . . . . . . .152
Running Spare Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .152
Deleting a Spare Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153
Managing Logical Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .154
Viewing Logical Drive Information . . . . . . . . . . . . . . . . . . . . . .154
Setting an Alias for a Logical Drive . . . . . . . . . . . . . . . . . . . . .154
Setting Write Cache Policy . . . . . . . . . . . . . . . . . . . . . . . . . . .154
Setting Read Cache Policy . . . . . . . . . . . . . . . . . . . . . . . . . . .155
Initializing a Logical Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . .155

VessRAID 1740s, 1840s Product Manual
x
Chapter 5: Management with the CLU, cont.
Managing Logical Drives, cont.
Running Redundancy Check . . . . . . . . . . . . . . . . . . . . . . . . .156
Locating a Logical Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . .156
Managing the Network Connection . . . . . . . . . . . . . . . . . . . . . . . .157
Making Management Port Settings . . . . . . . . . . . . . . . . . . . . .157
Managing SAS Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158
Viewing SAS Port Information . . . . . . . . . . . . . . . . . . . . . . . . .158
Making SAS Port Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . .158
Viewing SAS Port Statistics . . . . . . . . . . . . . . . . . . . . . . . . . .159
Viewing SAS Initiators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159
Adding a SAS Initiator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159
Managing Background Activity . . . . . . . . . . . . . . . . . . . . . . . . . . .160
Viewing Current Background Activities . . . . . . . . . . . . . . . . . .160
Making Background Activity Settings . . . . . . . . . . . . . . . . . . .160
Working with the Event Viewer . . . . . . . . . . . . . . . . . . . . . . . . . . .162
Viewing Runtime Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . .162
Clearing Runtime Events . . . . . . . . . . . . . . . . . . . . . . . . . . . .162
Viewing NVRAM Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . .162
Clearing NVRAM Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163
Working with LUN Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .164
Viewing a List of Initiators . . . . . . . . . . . . . . . . . . . . . . . . . . . .164
Enabling LUN Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .164
Creating an Initiator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .164
Mapping a LUN to an Initiator . . . . . . . . . . . . . . . . . . . . . . . . .165
Deleting an Initiator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .165
Managing Users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166
Viewing User Information . . . . . . . . . . . . . . . . . . . . . . . . . . . .166
Creating a User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166
Changing a User’s Password . . . . . . . . . . . . . . . . . . . . . . . . .167
Changing a User’s Display Name and Email Address . . . . . .167
Changing a User’s Privilege and Status . . . . . . . . . . . . . . . . .168
Deleting a User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168
Working with Software Management . . . . . . . . . . . . . . . . . . . . . . .169
Making Email Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169
Making SLP Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170
Making Web Server Settings . . . . . . . . . . . . . . . . . . . . . . . . .170
Making Telnet Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .171
Making SNMP Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .171
Managing SNMP Trap Sinks . . . . . . . . . . . . . . . . . . . . . . . . . .172

Contents
xi
Chapter 5: Management with the CLU, cont.
Working with Software Management, cont.
Making Netsend Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . .173
Managing Netsend Recipients . . . . . . . . . . . . . . . . . . . . . . . .173
Flashing through TFTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175
Viewing Flash Image Information . . . . . . . . . . . . . . . . . . . . . . . . .175
Clearing Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175
Restoring Factory Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .176
Shutting Down the Subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . .177
Shutting down the VessRAID – Telnet Connection . . . . . . . .177
Shutting down the VessRAID – Serial Connection . . . . . . . . .177
Restarting the Subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .179
Restarting VessRAID – Telnet Connection . . . . . . . . . . . . . . .179
Restarting VessRAID – Serial Connection . . . . . . . . . . . . . . .179
Making Buzzer Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181
Chapter 6: Management with the LCD Panel . . . . . . . . . . . . . . . . . .183
Using the LCD Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183
Perusing the Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184
Making Mode Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184
Simple Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184
Advanced Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .185
Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .185
Viewing Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .185
Managing the Network Connection . . . . . . . . . . . . . . . . . . . . . . . .186
Making Management Port Settings . . . . . . . . . . . . . . . . . . . . .186
Managing SAS Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . .187
Viewing SAS Port Information . . . . . . . . . . . . . . . . . . . . . . . . .187
Making SAS Port Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . .188
Managing the Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .188
Viewing Controller Information . . . . . . . . . . . . . . . . . . . . . . . .188
Managing Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189
Viewing the Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189
Making Buzzer Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189
Managing Physical Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190
Viewing Physical Drive Information . . . . . . . . . . . . . . . . . . . . .190
Locating a Physical Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . .191

VessRAID 1740s, 1840s Product Manual
xii
Chapter 6: Management with the LCD Panel, cont.
Managing Disk Arrays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .191
Creating a Disk Array – Automatic . . . . . . . . . . . . . . . . . . . . .192
Creating a Disk Array – Advanced . . . . . . . . . . . . . . . . . . . . .193
Deleting a Disk Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195
Viewing Disk Array Information . . . . . . . . . . . . . . . . . . . . . . . .195
Locating a a Disk Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196
Creating a Logical Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . .197
Deleting a Logical Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . .198
Viewing Logical Drive Information . . . . . . . . . . . . . . . . . . . . . .198
Locating a a Logical Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . .199
Managing Spare Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200
Viewing Spare Drive Information . . . . . . . . . . . . . . . . . . . . . .200
Creating a Spare Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201
Deleting a Spare Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201
Locating a Spare Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .202
Chapter 7: Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203
Updating the Firmware in WebPAM PROe . . . . . . . . . . . . . . . . . .203
Downloading the Firmware Image File . . . . . . . . . . . . . . . . . .203
Updating Firmware from TFTP Server . . . . . . . . . . . . . . . . . .203
Updating Firmware from your PC . . . . . . . . . . . . . . . . . . . . . .204
Restarting the Subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . .205
Updating the Firmware in the CLU . . . . . . . . . . . . . . . . . . . . . . . .206
Downloading the Firmware Image File . . . . . . . . . . . . . . . . . .206
Updating the Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .206
Restarting Subsystem over a Telnet Connection . . . . . . . . . .207
Restarting Subsystem over a Serial Connection . . . . . . . . . .207
Replacing a Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .208
VessRAID 1740s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .208
VessRAID 1840s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .208
Replacing a RAID Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . .209
Removing the old controller . . . . . . . . . . . . . . . . . . . . . . . . . .209
Installing the new controller . . . . . . . . . . . . . . . . . . . . . . . . . .210
Replacing a Cooling Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .210
Replacing the Cache Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212
Replacing the Memory Module . . . . . . . . . . . . . . . . . . . . . . . . . . .214

Contents
xiii
Chapter 8: Technology Background . . . . . . . . . . . . . . . . . . . . . . . .217
Introduction to RAID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217
RAID 0 – Stripe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .218
RAID 1 – Mirror . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219
RAID 1E – Enhanced Mirror . . . . . . . . . . . . . . . . . . . . . . . . . .220
RAID 5 – Block and Parity Stripe . . . . . . . . . . . . . . . . . . . . . .221
RAID 6 – Block and Double Parity Stripe . . . . . . . . . . . . . . . .222
RAID 10 – Mirror / Stripe . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223
RAID 50 – Striping of Distributed Parity . . . . . . . . . . . . . . . . .224
RAID 60 – Striping of Double Parity . . . . . . . . . . . . . . . . . . . .227
Choosing a RAID Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230
RAID 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230
RAID 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230
RAID 1E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .231
RAID 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .231
RAID 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .231
RAID 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .232
RAID 50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .232
RAID 60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .232
Choosing Stripe Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .233
Choosing Sector Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .233
2 TB Limitation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .234
Cache Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .234
Read Cache Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .235
Write Cache Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .235
Adaptive Writeback Cache . . . . . . . . . . . . . . . . . . . . . . . . . . .235
Capacity Coercion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .236
Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .236
Hot Spare Drive(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .237
Partition and Format the Logical Drive . . . . . . . . . . . . . . . . . . . . .237
RAID Level Migration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .238
Ranges of Disk Array Expansion . . . . . . . . . . . . . . . . . . . . . .244
Media Patrol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .245
Predictive Data Migration (PDM) . . . . . . . . . . . . . . . . . . . . . . . . . .246
PDM Triggers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .246
Transition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .247
Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248

VessRAID 1740s, 1840s Product Manual
xiv
Chapter 9: Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .251
VessRAID is Beeping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .251
LEDs Display Amber or Red . . . . . . . . . . . . . . . . . . . . . . . . . . . . .252
Front Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .252
Disk Drive LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .253
LCD Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .254
Controller LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .254
CLU Reports a Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .256
Viewing Runtime Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . .256
Viewing NVRAM Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . .256
Checking a Reported Component . . . . . . . . . . . . . . . . . . . . . .257
WebPAM PROe Reports a Problem . . . . . . . . . . . . . . . . . . . . . . .258
LCD Panel Reports a Problem . . . . . . . . . . . . . . . . . . . . . . . . . . .261
Viewing a Report from OPAS . . . . . . . . . . . . . . . . . . . . . . . . . . . .261
Event Notification Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . .263
Critical & Offline Disk Arrays . . . . . . . . . . . . . . . . . . . . . . . . . . . . .276
When a Physical Drive Fails . . . . . . . . . . . . . . . . . . . . . . . . . .276
With a Hot Spare Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .277
Without a Hot Spare Drive . . . . . . . . . . . . . . . . . . . . . . . . . . .277
Rebuild Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .278
Incomplete Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .279
Physical Drive Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .280
Physical Drive Offline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .280
Physical Drive Not Usable . . . . . . . . . . . . . . . . . . . . . . . . . . .280
Physical Drive Failed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .280
Enclosure Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .282
Connection Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .285
Serial Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .285
Network Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .286
Browser Does Not Connect to WebPAM PROe . . . . . . . . . . . . . .287
Unsaved Data in the Controller Cache . . . . . . . . . . . . . . . . . . . . .288
Chapter 10: Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289
Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289
Contacting Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . .291
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .295
Returning the Product For Repair . . . . . . . . . . . . . . . . . . . . . . . . .297
Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .299

1
Chapter 1: Introduction to VessRAID
This chapter covers the following topics:
• About This Manual (below)
• VessRAID Overview (page 2)
• Architectural Description (page 3)
• Features and Benefits (page 3)
• Specifications (page 6)
About This Manual
This Product Manual describes how to setup, use, and maintain the VessRAID
1740s and 1840s external disk array subsystems. It also describes how to use
the built-in command-line interface (CLI), command-line utility (CLU) and
embedded Web-based Promise Array Management—Professional (WebPAM
PROe) software.
This manual includes a full table of contents, index, chapter task lists, and
numerous cross-references to help you find the specific information you are
looking for.
Also included are four levels of notices:
Note
A Note provides helpful information such as hints or alternative
ways of doing a task.
Important
An Important calls attention to an essential step or point required
to complete a task. Important items include things often missed.
Caution
A Caution informs you of possible equipment damage or loss of
data and how to avoid them.
Warning
A Warning notifies you of probable equipment damage or loss of
data, or the possibility of physical injury, and how to avoid them.

VessRAID 1740s, 1840s Product Manual
2
VessRAID Overview
VessRAID provides data storage solutions for applications where high
performance and data protection are required. The failure of any single drive will
not affect data integrity or accessibility of the data in a RAID protected logical
drive.
Figure 1. VessRAID front view
A defective drive may be replaced without interruption of data availability to the
host computer. If so configured, a hot spare drive will automatically replace a
failed drive, securing the fault-tolerant integrity of the logical drive. The self-
contained hardware-based RAID logical drive provides maximum performance in
a compact external chassis.
Figure 2. VessRAID 1740 rear view
Drive Carrier LEDs
Drive Carriers Power and Status LEDs
RAID Controller
Power Supply

Chapter 1: Introduction to VessRAID
3
Architectural Description
The VessRAID 1740s and 1840s are Serial Attached SCSI (SAS) subsystems
suitable for Direct Attached Storage (DAS) and Expanded Storage.
The VessRAID subsystems support:
• 3.0 Gb/s SATA disk drives
• 3.0 Gb/s SAS disk drives
All VessRAID enclosures include a mid-plane, RAID controller, power supply unit,
and enclosure processor all in one cable-less chassis design. Multiple fans and
optional power supplies provide redundancy to ensure continued usage during
component failure. The RAID controller is hardware based and controls all logical
drive functions transparently to the host system. VessRAID appears to the
computer’s operating system as a standard SCSI drive or drives.
Features and Benefits
Highlights
• Intel 81348 I/O Processor with 4MB NOR flash memory, 128 MB NAND flash
memory for additional functions and 128 KB 8-bit NVRAM.
• 512 MB DDRII SDRAM DIMM expandable to 2GB.
• SDRAM has battery backup up to 72 hours.
• PMC PM8388 expander with 2MB flash memory.
• 10/100Mb RJ45 Ethernet management port.
• RJ11 serial port supports RS232 protocol via adapter cable.
• USB 2.0 external ports for subsystem management.
• 16 hot-swappable drive bays in a robust 3U rackmount chassis.
• Redundant, hot-swappable power supplies on 1840s model.
• Supports for SAS and SATA 3 Gb/s drives simultaneously in the same
system—choose the drive that is best suited to your application.
• Dual 3 Gb/s SAS x4 host ports provide high-availability SAN and cluster-
friendly platform.
• JBOD expansion support through a 3 Gb/s SAS x4 port.
• Simplified remote management with a comprehensive embedded web-
based management via Ethernet—WebPAM PROe. Command Line
Interface Utility via RJ-11 Serial Port.
• Three years complete system limited warranty includes 24 x 7 email and
phone support with highly experienced technical support technicians and an
advanced replacements program.

VessRAID 1740s, 1840s Product Manual
4
• Support for the latest RAID technology—RAID 6—Protection from a
catastrophic double-drive failure.
• Resilient data protection features such as Predictive Data Migration™ and
PerfectRAID™ provide rock solid data protection.
• LUN Mapping and Masking bring flexibility for multiple application and OS
support on the same storage subsystem.
• Open architecture, industry’s most comprehensive support for SAS and
SATA hard drives and standards-based management interfaces including
SNMP and WBEM.
• Support for the industry standard Disk Data Format (DDF from SNIA)
ensures interoperability and drive roaming even among different RAID
vendors.
• Compatible with leading SAS hard drives, host bus adapters, and RAID
controllers.
Subsystem and Controller Features
• Drive Support: Up to 16 3.5" x 1" SAS or SATA 3 Gb/s hard disk drives.
• Supports any combination of SAS and SATA drives in the system.
• Staggered physical drive spin-up.
• External I/O Ports: Dual 3 Gb/s SAS x4 host ports; One external 3 Gb/s SAS
x4 port for JBOD expansion.
• Data Cache: Shared 512 MB predictive data cache (expandable to 2 GB);
Automatic write cache destaging; 72-hour battery backup (for 512 MB
cache).
• Command Queue Depth: 512 commands per VessRAID (up to 1024
commands with 512 MB memory).
Operational Features
• RAID Levels: RAID 0, 1, 1E, 5, 6, 10, 50, and 60 – Any combination of these
RAID levels can exist at the same time.
• Configurable RAID stripe size: 64 KB, 128 KB, 256 KB, 512 KB, and 1 MB
stripe size per logical drive.
• Background task priority tuning: Adjustment of minimum I/O reserved for
server use during all background tasks.
• Hot spares: Multiple global or dedicated hot-spare drives with revert option.
• Maximum LUNs per subsystem: 256 in any combination of RAID levels.
• Maximum LUNs per array: 32 logical drives (LUNs). Supports LUN carving
by allowing an array to be divided into multiple logical drives. Supports out-
of-order logical drive deletion and re-creation.

Chapter 1: Introduction to VessRAID
5
• Max LUNs per Target ID: Up to 256, depending on host side driver and
operating system.
• LUN Masking and Mapping: Supports multiple hosts.
• Disk Data Formats: Supports Disk Data Format (DDF) for industry-wide
standardization and drive roaming between VTrak systems.
• Background Activities: Media Patrol, background synchronizing, disk array
rebuild, Redundancy Check, SMART condition pooling, Online Capacity
Expansion (OCE), RAID Level Migration (RLM). Includes priority control, rate
control, and watermarking per BGA in disk and NVRAM.
• Foreground Activities: Disk array initialization.
• Physical Drive Error Recovery: Predictive Data Migration (PDM), replaces
un-healthy disk member in array, while maintaining normal array status
during the data transition. Bad Sector Mapping, Media Patrol, SMART, Hard/
Soft Reset to recover HD from bad status, HD Power-control to recover HD
from hung status.
• Array Error Recovery: Data recovery from bad sector or failed HD for
redundant RAID, RAID 5/6 inconsistent data Prevent (Write Hole Table),
Data content Error Prevent (Read/Write Check Table) NVRAM event
logging.
• SCSI Commands: Supports extensive SCSI command set equivalent to
SCSI/FC hard disk drives. Variable sector size (512 byte to 4 KB) to break
OS 2TB limitation. 16 byte CDB support for 64-bit LBA addressing.
Management
• Supported Operating Systems: Windows 2003 Server, Windows 2008
Server, Linux (Red Hat, SuSE), Macintosh OS X, Solaris.
• Management Tools: WebPAM PROe via out-of-band Ethernet. OS
independent, localized in multiple languages, SSL Security support.
Command Line Interface (CLI) and Command Line Utility (CLU) via RJ-11
Serial Port or Telnet.
• Standard Management Protocols: SNMP and WBEM
• RAID Creation: Automatic, Express, and Advanced configuration support for
novice to skilled users.
• Management Interfaces: WebPAM PROe, CLU, CLI, audible (buzzer) and
visible (LEDs) alarms.
• Management Protocols: Embedded web server and management support—
no host agent needed. Ethernet, RJ-11 serial port, SNMP, SSL, Telnet,
Email.

VessRAID 1740s, 1840s Product Manual
6
Specifications
Power Supply:
100-240 VAC auto-ranging, 50-60 Hz, with PFC and 80PLUS certified
1740s, single. 1840s, dual hot swap and redundant
Current (maximum): 8 A @ 100 VAC or 4 A @ 240 VAC Current rating with two
power cords.
Power Consumption:
Without disk drives, 41.8 W
With disk drives, 220.1 W
Temperature: 5° to 40°C operational (-40° to 60°C non-operational)
Relative Humidity: Maximum 95 percent.
Vibration: Random, 0.21 grms, 5-500 Hz, 30 Mins, X, Y, Z axis.
Dimensions (H x W x D): 13 x 45 x 46 cm (5.1 x 17.7 x 18.1 in)
Net Weight:
1740s, 14.0 kg (30.9 lb) without drives, 22.0 kg (48.5 lb) with 16 drives*
1840s, 16.0 kg (35.3 lb) without drives, 24.0 kg (52.9 lb) with 16 drives*
* Assuming 0.5 kg (1.1 lb) per drive.
Gross Weight (including carton):
1740s, 19.2 kg (42.3 lb) without drives.
1840s, 20.8 kg (45.9 lb) without drives.
Safety: BSMI, CB, CCC, CE, FCC Class B, MIC, VCCI, UL, cUL, TUV.
Environmental: RoHS, China RoHS.
Warranty and Support
Warranty: Three year limited warranty on all components except the battery
backup unit, which has a one-year warranty.
Support: 24x7 email and phone support (English only). 24x7 access to Promise
support site for drivers, firmware, and compatibility.
CE Statement
Warning: This is a class B product. In a domestic environment this product may
cause radio interference in which case the user may be required to take
adequate measures.
This manual suits for next models
1
Table of contents
Other Promise Network Storage Server manuals

Promise
Promise PegasusPro R8 User manual

Promise
Promise PegasusPro R16 User manual

Promise
Promise E310f User manual

Promise
Promise VSky H3970rDM User manual

Promise
Promise VSky H3970 User manual

Promise
Promise VTRAK 15100 User manual

Promise
Promise ConnectStor II User manual

Promise
Promise VTRAK M610i User manual

Promise
Promise SmartStor NS4700 User manual

Promise
Promise VTRAK J300S User manual