INSTALLATION GUIDE
ENGLISH
Code: ARAD4S
Name: RACK 4U/270mm universal enclosure
for RACK 19" two-level cabinets
Metallic enclosure for RACK cabinet: CCTV, KD, SSWiN, RTV, LAN
IM ARAD4S
Edition: 2 from 04.10.2021
Supersedes the edition: 1 from 20.03.2017
EN
1. Intended use:
Due to its design, the ARAD4S enclosure is intended for mounting inside RACK 19'' cabinets. This general-
purpose enclosure may serve as an auxiliary element for integrating CCTV, AC, I&HAS, RTV, LAN systems in RACK 19''
cabinets. It is intended for mounting alarm control panels, AC controllers, power supply units, batteries, etc.
2. Description
The enclosure is equipped with two bottom-mounted mounting plates and a removable hinged mounting plate
(I and II level) for mounting electronics/transformers/power supply units. The enclosure can accommodate a 17Ah/12V
battery and it features tampering protection (against unwanted opening). To enable leading cables into the enclosure,
one can buy a cable protection conduit of any length and a cable gland. The conduits and the cable glands are available
at the following codes:
1) ARAP16P –cable gland, inside diameter 16 mm –connection between the protection conduit and the enclosure
2) ARAP21P –cable gland, inside diameter 21 mm –connection between the protection conduit and the enclosure
3) MM019 –cable protection conduit , inside diameter 16 mm
4) MM020 –cable protection conduit, inside diameter 21 mm
The ARAD4 enclosure has a space for up to 4x ARAP16P and 8x ARAP21P cable glands.
Optionally, ARAW45 fans can be mounted. They trigger airflow inside the enclosure after exceeding 45oC. One
enclosure can accommodate max. two fan units in the rear part of the enclosure.