ERROR MESSAGE
When there is an error, digital LED will display the error code :
Over-temperature protection.
Input voltage is too high. This discharger accepts battery voltage from 5.4 to 35V, if
voltage higher than 35V, it will stop working and show error message.
Input voltage is too low. This discharger accepts battery voltage from 5.4 to 35V, if voltage
lower than 5.4V, it will stop working and show error message.
Battery
Type
No. of
Cell
Min. Cut-Off
Voltage Voltage
Min. Discharge Current (A)
Discharging power: 200W
Max. Discharge Current (A)
Discharging power: 200W
LiPo
2S 6.0 8.40 23.80 30.00
3S 9.0 12.60 15.87 22.20
4S 12.0 16.80 11. 9 0 16.60
5S 15.0 21.00 9.52 13.30
6S 18.0 25.20 7. 93 11.10
7S 21.0 29.40 6.80 9.52
8S 24.0 33.60 5.95 8.33
LiHV
2S 6.2 8.70 22.98 30.00
3S 9.3 13.05 15.32 21.50
4S 12.4 17. 4 0 11. 4 9 16.12
5S 15.5 21.75 9.19 12.90
6S 18.6 2 6.10 7. 6 6 10.75
7S 21.7 30.45 6.56 9.21
8S 24.8 34.80 5.74 8.06
NiMH
6S 5.4 9.00 22.22 30.00
7S 6.3 10.50 19.04 30.00
8S 7. 2 12.00 16.66 27.77
9S 8.1 13.50 14.81 24.69
10S 9.0 15.00 13.33 22.22
11S 9.9 16.50 12.12 20.20
12S 10.8 18.00 11.11 18.51
13S 11.7 19.50 10.25 17. 09
14S 12.6 21.00 9.52 15.87
15S 13.5 22.50 8.88 14.81
16S 14.4 24.00 8.33 13.88
17S 15.3 25.50 7. 8 4 13.07
18S 16.2 2 7.0 0 7. 4 0 12.34
19S 17.1 28.50 7.01 11.69
20S 18.0 30.00 6.66 11.11
PC SOFTWARE
• PC software supplied with the B-GEN 200 is easy to use, intuitive.
• There are two discharge mode: Constant Power and Constant
Current.
• The software can automatic sensing of battery cell count and
recommends a minimum safe discharge voltage.
• Discharge tests may be viewed in Amp Hours, Watt Hours or
Minutes.
• Results can be graphed as Voltage vs. Amp hours, Watt hours,
Minutes.
SAFETY NOTE
• Never discharge a battery below its recommended cut-off voltage. Over-discharge may damage
battery and cause FIRE or EXPLOSION.
• Never discharge a battery at a higher discharge rate than it is designed for.
• Never leave the discharger unattended when it is connected to battery. If any malfunction is found,
TERMINATE THE PROCESS AT ONCE.
• Place the discharger and battery on a non-flammable surface, and keep away from inflammables.
• Never discharge swollen, leaky, or damaged batteries.
• Batteries shall be discharged within a room temperature range of 10-40°C.
• Disconnect the battery and discharger once discharging has nished.
• Recharge batteries immediately with an appropriate battery charger after discharge process is
completed. Some battery types do not like to remain discharged for extended periods of time.
WARRANTY AND SERVICE
We guarantee this product to be free of manufacturing and assembly defects for a period of 12 or 24 months from the
time of purchase. The warranty only applies to material or operational defects, which are present at the time of purchase.
During that period, we will repair or replace free of service charge for products deemed defective due to those causes.
You will be required to produce proof of purchase (invoice or receipt). This warranty is not valid for any damage or
subsequent damage arising as a result of misuse, modication or as a result of failure to observe the procedures outlined
in this manual.
DURATION OF VALIDITY
The claim period is 24 months from the date of purchase of the product by the consumer from a dealer in the European
Community (EC) counted from the date of purchase. The claim period is 12 months from the date of purchase of the
product by the consumer from a dealer outside the European Community (EC) counted from the date of purchase. If a
defect arises after the end of the claim period, or if evidence or documents required according to this declaration in order
to make the claim valid are not presented until after this period, then the consumer forfeits any rights or claims from this
declaration. The guarantee period is not prolonged by the granting of any claims within the framework of this warranty,
especially in the case of repair or replacement. The guarantee period also does not restart in such cases.
WARRANTY EXPIRATION
If we do not acknowledge the validity of a claim based on this declaration within the claim period, all claims based on this
declaration will expire after six months from the time of registering the claim; however this cannot occur prior to the end
of the claim period.
TCRP INTERNA
TIONAL LLC Ltd • 21B Moskovska Street. Floor 3 • 1000 Soa - Bulgaria •
[email protected] - www.pulsetec.eu3 4
Download
English Manual
Téléchargez le Manuel
en Français
Download
Deutsche Anleitung