Pyxis LS-200 User manual

Table of Contents
1 Introducon 2
2 Specicaons 2
3 Unpacking Instrument 2
3.1 Standard Provided Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.2 OponalAccessories ..................................... 3
4 Installaon 3
4.1 Tank Top Installaon and Precauons . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4.2 Wiring............................................. 4
5 Instrument Overview 5
6 Setup with uPyxis® Mobile App 6
6.1 Download uPyxis® Mobile App . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
6.2 Connecng to uPyxis® Mobile App . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
6.3 OverviewScreen ....................................... 7
6.4 ReadingScreen ........................................ 8
6.5 SengsScreen ........................................ 8
7 Setup with uPyxis® Desktop App 9
7.1 InstalluPyxis®DesktopApp.................................. 9
7.2 Connecng to uPyxis® DesktopApp ............................. 10
7.3 OverviewScreen ....................................... 10
7.4 ReadingScreen ........................................ 11
7.5 SengScreen......................................... 12
8 Outputs 13
8.1 4–20mAOutputSetup .................................... 13
8.2 Communicaon Using Modbus RTU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
9 Sensor Maintenance and Precauon 13
10 Regulatory Approval 14
11 Contact Us 14

Warranty Informaon
Condenality
The informaon contained in this manual may be condenal and proprietary and is the property of Pyxis
Lab, Inc. Informaon disclosed herein shall not be used to manufacture, construct, or otherwise reproduce
the goods described. Informaon disclosed herein shall not be disclosed to others or made public in any
manner without the express wrien consent of Pyxis Lab, Inc.
Standard Limited Warranty
Pyxis Lab warrants its products for defects in materials and workmanship. Pyxis Lab will, at its opon, repair
or replace instrument components that prove to be defecve with new or remanufactured components
(i.e., equivalent to new). The warranty set forth is exclusive and no other warranty, whether wrien or oral,
is expressed or implied.
Warranty Term
The Pyxis warranty term is thirteen (13) months ex-works. In no event shall the standard limited warranty
coverage extend beyond thirteen (13) months from original shipment date.
Warranty Service
Damaged or dysfunconal instruments may be returned to Pyxis for repair or replacement. In some in-
stances, replacement instruments may be available for short duraon loan or lease.
Pyxis warrants that any labor services provided shall conform to the reasonable standards of technical com-
petency and performance eecve at the me of delivery. All service intervenons are to be reviewed and
authorized as correct and complete at the compleon of the service by a customer representave, or des-
ignate. Pyxis warrants these services for 30 days aer the authorizaon and will correct any qualifying
deciency in labor provided that the labor service deciency is exactly related to the originang event. No
other remedy, other than the provision of labor services, may be applicable.
Repair components (parts and materials), but not consumables, provided during a repair, or purchased
individually, are warranted for 90 days ex-works for materials and workmanship. In no event will the in-
corporaon of a warranted repair component into an instrument extend the whole instrument’s warranty
beyond its original term.
Warranty Shipping
A Repair Authorizaon (RA) Number must be obtained from Pyxis Technical Support before any product can
be returned to the factory. Pyxis will pay freight charges to ship replacement or repaired products to the
customer. The customer shall pay freight charges for returning products to Pyxis. Any product returned to
the factory without an RA number will be returned to the customer. To receive an RMA you can generate a
request on our website at hps://pyxis-lab.com/request-tech-support/.
Pyxis Technical Support
Contact Pyxis Technical Support at +1 (866) 203-8397, [email protected], or by lling out a request for
support at hps://pyxis-lab.com/request-tech-support/.

1 Introducon
The Pyxis LS-200 is a general-purpose ultrasonic sensor. It provides connuous level measurement up to 86
inches (7.2 or 2.2 m) with a 4–20mA output, RS-485, and Bluetooth digital outputs. It can be congured
via the uPyxis® App on your mobile phones or computers. The sensor is powered by a 24 VDC external
power supply. This non-contact liquid level sensor is well suited for corrosive liquids and can be used for
industrial and municipal liquid storage and chemical feed applicaons.
2 Specicaons
Table 1. LS-200 Specicaons
Specicaon*LS-200
Part Number (P/N) 54011
Range 4–86 inch (0.01–2.2 m)
Resoluon 0.02 inch (0.5 mm)
Accuracy ±0.15% of the range
Measurement
Interval
Connuous, 10 or 30 seconds, 3 or 30 minutes, 1 or 4 or 6 hours, or stopped
Output Bluetooth 5, 32 (10 m) Line of Sight, 4–20mA Analog Output, RS-485 Digital
Output with Modbus protocol
Installaon 1” male NPT
Cable Length 9.8 (3 m), extension cable available
Power Supply 24 VDC, 2 W
Dead Zone 4 inch (10 cm)
Dimension (H ×
Dia)
4.33 ×2.95 inch (110 ×75 mm)
Weight 0.45 lbs (210 g)
Enclosure Material Polycarbonate (PC)
Transducer Material Polyvinylidene Fluoride (PVDF)
Operaonal
Temperature
5–122 °F (-15–50 °C)
Storage
Temperature
-4–140 °F (-20–60 °C)
Pressure 14–30 psi (0.1–0.2 MPa)
Enclosure Rang IP67
Regulaon CE
*With Pyxis’s connuous improvement policy, these specicaons are subject to change without noce.
3 Unpacking Instrument
Remove the instrument and nd the standard accessories from the shipping container as listed below. In-
spect each item for any damage that may have occurred during shipping. Verify that all accessory items are
included. If any item is missing or damaged, please contact Pyxis Lab Customer Service at service@pyxis-
lab.com or by phone at +1 (866) 203-8397.

3.1 Standard Provided Accessories
• Waterproof Cable Adapter/Flying Leads (10 ) P/N: 50774
• User Manual available online at hps://pyxis-lab.com/product/ls-200-ultrasonic-level-sensor/
3.2 Oponal Accessories
The following oponal accessories can be ordered from Pyxis Customer Service (order@pyxis-lab.com) or
Pyxis eStore at hps://pyxis-lab.com/shop/.
Figure 1.
4 Installaon
4.1 Tank Top Installaon and Precauons
The sensor should be installed to a 1-inch bulkhead ng on the top of the tank. The major dimensions of
the sensor are shown in Figure 2. If a at horizontal surface is not available on the top of the tank, please use
a self-aligning bulkhead ng so that the sensor can be adjusted to be perpendicular to the liquid surface.
• Install and adjust the sensor to be perpendicular to liquid surface
• Installaon locaon shall not be too close to container wall to avoid interference.
• The sensor has a 3.94 inch (10 cm) dead zone (DZ). Raise the probe to avoid the DZ if desired
• Do not install in a locaon which will cause the ultrasonic wave to be obstructed
• Do not install the sensor in a vacuum environment
Figure 2. Installaon illustraon

Figure 3. Dimensions, inch (mm)
4.2 Wiring
If the power ground terminal and the negave 4–20mA terminal in the controller are internally connected
(non-isolated 4–20mA input), it is unnecessary to connect the 4–20mA negave wire (green) to the 4–20mA
negave terminal in the controller. If a separate DC power supply other than that from the controller is used,
make sure that the output from the power supply is rated for 22–26 VDC @ 65 mA.
*NOTE*The negave 24V power terminal (power ground) and the negave 4–20mA ter-
minal on the LS-200 are internally connected.
Follow the wiring table below to connect the LS-200 to a controller:
Table 2.
Wire Color Designaon
Red 24V +
Black 24V Power ground
White 4–20mA +
Green*4–20mA -
Blue RS-485 A
Yellow RS-485 B
Clear Shield, earth ground
*Internally connected to the power
ground

5 Instrument Overview
The indicators on the top of the sensor (Figure 4) are used to indicate power status and Bluetooth connec-
on status.
Table 3.
LED Status On O
Green LED Power Supply is on Power Supply is o
Blue LED Bluetooth is connected Bluetooth is disconnected
*NOTE*The Bluetooth connected LED will illuminate within 30 seconds of powerup of the
device. This feature is designed to minimize controller power draw during startup.
Figure 4. Sensor connecon and indicators

6 Setup with uPyxis® Mobile App
6.1 Download uPyxis® Mobile App
Download uPyxis® Mobile App from Apple App Store or Google Play.
Figure 5.
6.2 Connecng to uPyxis® Mobile App
Connect the LS-200 sensor to a mobile smart phone according to the following steps:
1. Open uPyxis® Mobile App.
2. On uPyxis® Mobile App, pull down to refresh the list of available Pyxis devices.
3. If the connecon is successful, the LS-200 and its Serial Number (SN) will be displayed (Figure 6).
4. Press on the LS-200 image.

6.4 Reading Screen
The READING screen displays the current volume of liquid remaining and liquid level over me.
Figure 8.
6.5 Sengs Screen
The sensor measures the distance between the liquid surface in the tank and the boom sensor surface.
Converng this measured distance to other parameters such as the tank level, the remaining liquid volume,
or the consumed liquid, requires the tank dimensional and volume capacity informaon. Common vercal
tanks have a uniform horizontal cross secon.
*NOTE*For horizontal or other tanks that have a non-uniform cross secon, please contact
Pyxis Technical Support team (service@pyxis-lab.com) for assistance.
To convert the measured distance to volumetric informaon, the user must enter three parameters via the
uPyxis® Mobile App’s Seng screen:
•Tank Volume (rated volume capacity of the tank)
•Installaon Height (from the boom of the tank to the boom of the LS-200)
•Max Level Height (from the boom of the tank to the liquid surface when lled to the rated capacity)
*NOTE*Max Level Height must be at least 4 inches less than Installaon Height
Figure 9 illustrates these parameters for the tank.
In the SETTING screen, the you can also set the Device Name, the Sampling Mode,LCD Display Value,LCD
Screen O Time (in seconds), and the Display Unit. To save the sengs, press APPLY SETTINGS. You may
also create or change a password for the LS-200 by pressing MANAGE PASSWORD.

Figure 9. Figure 10.
7 Setup with uPyxis® Desktop App
7.1 Install uPyxis® Desktop App
Download the latest version of uPyxis® Desktop soware package from: hp://www.pyxis-lab.com/sup-
port.html. This setup package will download and install the Microso.Net Framework 4.5 (if not installed
on the PC before), the USB driver for the USB-Bluetooth adapter, the USB-RS485 adapter, and the main
uPyxis® Desktop applicaon. Double click the uPyxis.Setup.exe le to install.
Figure 11. uPyxis® desktop app installaon
Click Install to start the installaon process. Follow the screen instrucons to complete the USB driver and
uPyxis® installaon.

7.2 Connecng to uPyxis® Desktop App
Connect the LS-200 sensor to a Windows computer using a Bluetooth/USB adapter (P/N: MA-NEB) according
to the following steps:
1. Plug the Bluetooth/USB adapter into a USB port in the computer.
2. Launch uPyxis® Desktop App.
3. On uPyxis® Desktop App, click Device →Connect via USB-Bluetooth (Figure 12).
4. If the connecon is successful, the LS-200 and its Serial Number (SN) will be displayed in the le pane
of the uPyxis® window.
*NOTE*Aer the sensor and Bluetooth is powered up, it may take up to 10 seconds for the
adapter to establish the wireless signal for communicaon.
Figure 12.
7.3 Overview Screen
When connected, the uPyxis® Desktop App will default to the Overview screen. The Overview screen
displays the current liquid level and volume of liquid remaining.

7.5 Seng Screen
The sensor measures the distance between the liquid surface in the tank and the boom sensor surface.
Converng this measured distance to other parameters such as the tank level, the remaining liquid volume,
or the consumed liquid, requires the tank dimensional and volume capacity informaon. Common vercal
tanks have a uniform horizontal cross secon.
*NOTE*For horizontal or other tanks that have a non-uniform cross secon, please contact
Pyxis Technical Support team (service@pyxis-lab.com) for assistance.
To convert the measured distance to volumetric informaon, the user must enter three parameters via the
uPyxis® Mobile App’s Seng screen:
•Tank Volume (rated volume capacity of the tank)
•Installaon Height (from the boom of the tank to the boom of the LS-200)
•Max Level Height (from the boom of the tank to the liquid surface when lled to the rated capacity)
*NOTE*Max Level Height must be at least 4 inches less than Installaon Height
Figure 15 illustrates these parameters for the tank.
In the Seng screen, the you can also set the Device Name, the Sampling Interval,LCD Display Value,LCD
Screen O Time (in seconds), and the Display Unit. To save the sengs, press Apply Sengs.
Figure 15.

8 Outputs
8.1 4–20mA Output Setup
The 4–20mA output of the sensor is scaled as:
• 4 mA = (Tank is Empty) = (Level is 0) = (Distance is Installaon Height),
• 20 mA = (Tank is Full) = (Level is maximum height) = (Distance is Installaon Height – Maximum
Height).
The 4–20mA analog signal can be converted to one of four values (Level, Distance, Volume Remaining, or
Volume Consumed) in the controller receiving the output according to the above scale. For example, a
nominal 100-gallon vercal tank, the maximum height is 36 inches and installaon height is 42 inches. The
tank volume is 100 gallons when it is lled up to the maximum height 36 inches. The controller should be
set up to convert 20 mA to 100 gallons, at which the tank is full and the tank level is 36 inches and the
distance measured is 6 inches.
*NOTE*The nominal capacity provided by the tank manufacturer may be greater than the
maximum safe (net or eecve) capacity that can be praccally lled. Please keep this in
mind as you congure your LS-200 for praccal purposes.
8.2 Communicaon Using Modbus RTU
The sensor can be congured as a Modbus slave device via RS-485. In addion to the level, volume, and
distance, many operaonal parameters, including warning and error messages, are available via a Modbus
9 Sensor Maintenance and Precauon
For best performance, keep the sensor ultrasonic surface clean using a so cloth or towel. Noce that
somemes the maximum sound pressure level inside the beam area is up to 165dB, which exceeds the
standard safe limit of 110dB. Never point the probe at the eye. The direcvity paern of the probe is
shown in Figure 16.
Figure 16. Direcvity paern of the LS-200

10 Regulatory Approval
United States
The LS-200 sensor has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protecon against harmful
interference in a residenal installaon. This equipment generates, uses and can radiate radio frequency
energy, and if not installed and used in accordance with the instrucons, may cause harmful interference to
radio communicaons. However, there is no guarantee that interference will not occur in an installaon. If
this equipment does cause harmful interference to radio or television recepon, which can be determined
by turning the equipment o and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separaon between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from that to which the receiver is con-
nected.
• Consult the dealer or an experienced radio/TV technician for help
Canada
This device complies with Industry Canada license exempt RSS standard(s). Operaon is subject to the
following two condions: (1) this device may not cause interference, and (2) this device must accept any in-
terference, including interference that may cause undesired operaon of the device. Le présent appareil est
conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitaon est
autorisée aux deux condions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’ulisateur
de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est suscepble
11 Contact Us
Pyxis Lab, Inc
1729 Majesc Dr. Suite 5
Lafayee, CO 80026 USA
www.pyxis-lab.com
Phone: +1 (866) 203-8397
Email: [email protected]
Other manuals for LS-200
2
This manual suits for next models
1
Table of contents
Other Pyxis Accessories manuals

Pyxis
Pyxis ST-772 User manual

Pyxis
Pyxis LSP Series User manual

Pyxis
Pyxis HM-500 Series User manual

Pyxis
Pyxis ST-525 User manual

Pyxis
Pyxis ST-590 Series User manual

Pyxis
Pyxis ST-500 User manual

Pyxis
Pyxis ST-565 User manual

Pyxis
Pyxis ST-500 User manual

Pyxis
Pyxis LS-202 User manual

Pyxis
Pyxis ST-700 Series User manual

Pyxis
Pyxis LSP-X01 Series User manual

Pyxis
Pyxis ST-765SS Series User manual

Pyxis
Pyxis LT-635 User manual

Pyxis
Pyxis ST-772 User manual

Pyxis
Pyxis ST-765SS-SO3 User manual

Pyxis
Pyxis ST-601 User manual

Pyxis
Pyxis ST-772 User manual

Pyxis
Pyxis ST-765SS Series User manual

Pyxis
Pyxis ST-710 User manual

Pyxis
Pyxis 53626 User manual