
IQ MOTION S-LINE INSTALLATION MANUAL
•Advanced circuit technology
resulting in ultra-low power
consumption
•40 lb. Pet immunity
•Tamper detection/reporting
•Rigid wall mounting for discreet
placement
•Easy to install batteries
•Supervisory health messaging
•Wireless signal range: 600 ft, open air
•Compatible control panels: Qolsys IQ Panel 2
•Code outputs: paring, tamper, tamper restore, alarm detect motion,
alarm restore, supervisory, low battery
•Transmitter frequency: 319.5MHZ +-15KHz
•Transmitter bandwidth: 24KHZ
•Modulation type: ASK-OOK
•RF output power!91.1dBuV +/- 5% at 3m
•Sensor Range 30 ft x 40 ft
•Maximum Horizontal Sensing Angle 80°
•Sensor: 3.4H x 2.4W x 1.5D in.
•Replace batteries every 5 years with AAA Alkaline (x2). Detector
intended for use with (2) Huizhou Deanda Battery Co. AAA LR03.
•The sensor should be permanently mounted in a corner or on a
flat wall that is free of vibrations, at a height of 7.5 feet.
•Mount the sensor on an insulated exterior wall facing in.
•Position the sensor to protect an area where an intruder is most
likely to walk across the detection pattern.
•Position the sensor so it faces a solid reference point, such as a
wall.
•If possible, mount the sensor within 100 ft of the panel. While
the transmitter may have a range of 600 ft or more out in the
open, the environment at the installation site can have a
significant effect on transmitter range. Verify actual transmitter
range for each installation.
•Close all windows in an area with an armed motion sensor.
•Aim the sensor at windows, fireplaces,
air conditioners, area heaters, forced
air heating vents or drapes.
•Place the sensor in direct sunlight as
sudden changes in temperature may
trigger a false alarm.
•Mount the sensor near duct work or
other large metallic surfaces that may
affect the RF signals.
•Set the sensor on a shelf.
•Mount outdoors or in a non-
temperature controlled environment.
•Mount at any other height than 7.5 ft.
Qolsys Inc. proprietary. Reproduction without permission is not permitted.
LOCATION MOUNTING GUIDELINES:
Avoid placement
looking at ceiling
fans
Outside walls
pointed away from
windows are great
locations
Avoid
HVAC
ducts &
drapes
Must
install at
7.5’ high
Position so that the expected motion is perpendicular to
the zones of detection. Test yearly.
Note: For UL/CUL installations use this device only in conjunction
with compatible Qolsys wireless alarm system IQ Panel 2.