R
Page 2 October 13, 2015
Yosemite Wood Stove
7004-187L
and Welcome to the Quadra-Fire Family!
Hearth & Home Technologies welcomes you to our tradition of
excellence! In choosing a Quadra-Fire appliance, you have our
assurance of commitment to quality, durability, and performance.
This commitment begins with our research of the market, including
‘Voice of the Customer’contacts, ensuring we make products that
will satisfy your needs. Our Research and Development facility
then employs the world’s most advanced technology to achieve
the optimum operation of our stoves, inserts and fireplaces. And
yet we are old-fashioned when it comes to craftsmanship. Each
unit is meticulously fabricated and gold and nickel surfaces are
hand-finished for lasting beauty and enjoyment. Our pledge to
quality is completed as each model undergoes a quality control
inspection.
We wish you and your family many years of enjoyment in the
warmth and comfort of your hearth appliance. Thank you for
choosing Quadra-Fire.
LABEL IS LOCATED ON THE BACK OF THE STOVE
Serial Number
Model Name
Testing Lab &
Report Number
1445 North Highway,
Colville, WA 99114
www.quadrafire.com
Manufactured by:
VENT SPECIFICATIONS:
SINGLE WALL: Six inch (6 inches) (152mm) diameter, minimum 24 MSG black or blued steel connector pipe, with a listed factory-built
UL103 HT Class "A" chimney, suitable for use with solid fuels, or a masonry chimney, and the referenced clearances.
DOUBLE WALL: Six inch (6 inches) (152mm) diameter, listed double wall air insulated connector pipe with listed factory-built UL103 HT
Class "A" chimney, or a masonry chimney and the referenced clearances.
*In Canada must comply with Standard CAN/ULC-S629-M87 for the 650 degree Factory-built chimneys.
MOBILE HOME: Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos DS or Security DLdouble wall connector pipe. Must be
equipped with a spark arrestor. Apply double wall clearances below when installing unit.
2015 2016 2017 Jan. Feb. Mar. Apr. May June July Aug. Sept. Oct. Nov. Dec.
DO NOT REMOVE THIS LABEL
LISTED ROOM HEATER, SOLID FUEL TYPE. ALSO FOR USE IN MOBILE
HOMES. (UM) 84-HUD .
"For Use with Solid Wood Fuel Only"
Install and use only in accordance with manufacturer's
installation and operating instructions. Contact local building or
fire officials about restrictions and installation inspections in
your area. Do not obstruct the space beneath heater.
WARNING - For Mobile Homes:
Do not install in a sleeping
room. An outside combustion air inlet must be provided and
unrestricted while unit is in use. The structural integrity of the
mobile home floor, ceiling and walls must be maintained. The
stove needs to be properly grounded to the frame of the mobile
home. Components required for mobile home installation:
Outside Air Kit, Part Number 831-1780.
Refer to manufacturer's instructions and local codes for
precautions required for passing chimney through a
combustible wall or ceiling and maximum offsets.
I
nspect and clean chimney frequently - Under Certain Conditions of
Use, Creosote Buildup May Occur Rapidly.
Do not connect this unit to a chimney serving another
appliance.
Optional Components: Optional Blower, Part 831-1701.
Electrical Rating: 115 VAC, 1.2 Amps, 60 Hz.
Route power cord away from unit. Do not route cord under or
in front of appliance.
DANGER: Risk of electrical shock. Disconnect power supply
before servicing.
Replace glass only with 5mm ceramic available from your dealer.
Do not use grate or elevate fire. Build wood fire directly on
firebrick.
Do not overfire - if heater or chimney connector glows, you are
overfiring.
Operate only with the fuel loading door closed. Open only to
add fuel to the fire.
U.S. ENVIRONMENTAL PROTECTIONAGENCY -
Certified to comply with 2015 particulate emission standards at 2.7 g/hr EPAMethods 28
and 5G. Not approved for sale after May 15, 2020.
PREVENT HOUSE FIRES
FLOOR PROTECTION*:
Floor protector must be
non-combustible material or
equivalent, extending beneath
heater and to front/sides/rear as
indicated on the diagram.
Exception: Non-combustible floor
protections must extend beneath
the flue pipe when installed with
horizontal venting and extend 2
inches (51mm) beyond each side.
Report: #061-S-54-2 TESTED TO:
UL 1482, UL737, ULC S627-00.
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN
BURNS. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE
NAMEPLATEAND INSTRUCTIONS.
SERIAL NO.
YOSEMITE
R
7004-188J
Minimum 16"
(406mm) from
fuel loading
door
8"(203mm)
USA
44-1/2"(1130mm) Minimum
36-11/16"
(932mm)
Minimum
Fuel loading doors
Front Side
Both fuel loading doors accessible
8"
(203mm) 16" (406mm) from fuel
loading door
8"
(203mm)
USA
Front Fuel
loading door
33"(838mm) Minimum
36-11/16"
(932mm)
Minimum
Side fuel loading door locked shut
TOP VENT VERTICAL
A B C1 C2* D1 D2* E1 E2* F1 F2* G H
Single Wall-USA
12.5(316) 9(229) 19.5(495) 25.5(648) 10(254) 16 (406) 14(356) 16(406) 18.5(470) 20.5(521) 59(1499) N/A
Single Wall-Canada 12.5(316) 9(229) 19.5(495) 27.5(669) 10(254) 18 (457) 14(356) 18(457) 18.5(470) 22.5(572) 59(1499) N/A
Double Wall- USA 10.5(267) 7(178) 19.5(495) 25.5(648) 10(254) 16(406) 7 (178) 16(406) 11.5(292) 20.5(521) 59(1499) N/A
Double Wall-Canada 1
0.5(267) 7(178) 19.5(495) 27.5(699) 10(254) 18(457) 7 (178) 18(457) 11.5(292) 22.5(572) 59(1499) N/A
HORIZONTAL WITH MINIMUM 2FT (609mm) VERTICAL OFF STOVE TOP
Single Wall-USA
13.5(343) 10(254) 19.5(495) 25.5(648) 10(254) 16 (406) N/A N/A N/A N/A 59(1499) 18**
Single Wall-Canada
13.5(343) 10(254) 19.5(495) 27.5(699) 10(254) 18 (457) N/A N/A N/A N/A 59(1499) 18**
Double Wall-USA 11.5(330) 8(203) 19.5(495) 25.5(648) 10(254) 16(406) N/A N/A N/A N/A 59(1499) 18**
Double Wall-Canada 11.5(330) 8(203) 19.5(495) 27.5(699) 10(254) 18(457) N/A N/A N/A N/A 59(1499) 18**
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: In Inches & (Millimeters)
NOTE: All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.
G
H
E2
F2
Fuel door
side
Non-fuel
door side
SEE MANUAL FOR OTHER CONFIGURATIONS
*In Canada: Must be minimum 18 inches (450mm) in front of both
fuel loading doors and 8 inches (200mm) on both sides and back.
**NFPA MINIMUM CLEARANCE - NOT TESTED
BA
C1
Non-fuel
door side
D2
Fuel Door
side
C2
D1
CAUTION:
007175
O-T L
Tested and
Listed by Portland
Oregon USA
OMNI-Test Laboratories, Inc.
CUS
Made in U.S.A. of US and imported parts.
This wood heater needs periodic inspection and repair for
proper operation. Consult the owner’s manual for further
information. It is against federal regulations to operate this
wood heater in a manner inconsistent with the operating
instructions in the owner’s manual.
Mfg. Date
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having jurisdiction