Thank you for purchasing the RAMFAN® Dual Battery Charger manufactured in the USA by
Euramco Group.
For more than 30 years Euramco Group has been on the cutting edge of industrial, re, and
marine ventilation products. Each of our blower/exhausters, smoke ejectors, PPV & LSV fans and
accessories represent the nest technologies available. Every product is constructed to demanding
and exact specications for quality, performance, and reliability.
Explore our website and online catalog at www.ramfan.com and discover how RAMFAN products
can make a dierence in the eld!
All product information in the publication is based on the most current information available at the
time of printing. Euramco Group reserves the right to make changes at any time without notice.
General Safety Rules
1. SAFETY GUIDELINES
• Read and understand this manual before use.
• Always check charger, connection cable, extension cable and plug for damage and deterioration
and repair as required before use.
• Keep the cables away from heat sources, oil and sharp edges.
• Store chargers outside the reach of children.
• Charger may not be exposed to rain or condensing humidity. Exposure to rain or condensing
humidity can cause battery charger to malfunction and increase risk of shock hazards.
• Safe handling of the charger is only guaranteed if the safety and operating information are
carefully read and adhered to.
• Do not use any chargers in an explosive environment such as in the vicinity of ammable liquids
gases or dust.
2. USE AND CARE
• Take proper care of the charger. Keep an eye out for defective connections, defects and all other
conditions that may aect the device’s operation. If any damage, repair the charger before
use.
• The charger may only be used with RAMFAN Model# R2-360-AH-U battery packs. The use of other
batteries can cause damage, injury or re.
• Battery pack(s) should not be stored for longer than 12 months without charging, to maintain
longterm reliability.
• The Charger is for charging RAMFAN 40V, 6AH Li-Ion battery packs, part# R2-360-AH-U only.
• Battery packs should not be used in the vicinity of metallic objects such as paper clips, coins,
nails, screws or other small metallic objects that could bridge and short out battery connection
terminals.
• Improper use of battery packs can lead to uid leaking from the battery; avoid any physical
contact with the uid. If you accidentally come into contact with this, wash the area concerned
thoroughly with water. Seek medical assistance if the uid gets into the eyes.
3. MAINTENANCE
• No user serviceable parts. Only allow qualied individuals to maintain the charger.
This will ensure the long-term safety of the charger.
4. Alert
• Battery packs at temperatures above 105ºF / 40ºC or below 4ºF / -20ºC will not accept a charge.

3
Basic Functions ............................................................................................................................. 4
Specications................................................................................................................................. 4
Installation..................................................................................................................................... 4
Charging Status............................................................................................................................. 5
Electrical Connections ................................................................................................................. 5
Back Pack Installation ................................................................................................................. 5
Warranty......................................................................................................................................... 6
Customer Service.......................................................................................................................... 6
Disposal........................................................................................................................................... 6
EC Declaration of Conformity .................................................................................................... 7
Drill Template................................................................................................................................ 8
CONTENTS
1. SAFETY GUIDELINES
• Read and understand this manual before use.
• Always check charger, connection cable, extension cable and plug for damage and deterioration
and repair as required before use.
• Keep the cables away from heat sources, oil and sharp edges.
• Store chargers outside the reach of children.
• Charger may not be exposed to rain or condensing humidity. Exposure to rain or condensing
humidity can cause battery charger to malfunction and increase risk of shock hazards.
• Safe handling of the charger is only guaranteed if the safety and operating information are
carefully read and adhered to.
• Do not use any chargers in an explosive environment such as in the vicinity of ammable liquids
gases or dust.
2. USE AND CARE
• Take proper care of the charger. Keep an eye out for defective connections, defects and all other
conditions that may aect the device’s operation. If any damage, repair the charger before
use.
• The charger may only be used with RAMFAN Model# R2-360-AH-U battery packs. The use of other
batteries can cause damage, injury or re.
• Battery pack(s) should not be stored for longer than 12 months without charging, to maintain
longterm reliability.
• The Charger is for charging RAMFAN 40V, 6AH Li-Ion battery packs, part# R2-360-AH-U only.
• Battery packs should not be used in the vicinity of metallic objects such as paper clips, coins,
nails, screws or other small metallic objects that could bridge and short out battery connection
terminals.
• Improper use of battery packs can lead to uid leaking from the battery; avoid any physical
contact with the uid. If you accidentally come into contact with this, wash the area concerned
thoroughly with water. Seek medical assistance if the uid gets into the eyes.
3. MAINTENANCE
• No user serviceable parts. Only allow qualied individuals to maintain the charger.
This will ensure the long-term safety of the charger.
4. Alert
• Battery packs at temperatures above 105ºF / 40ºC or below 4ºF / -20ºC will not accept a charge.

4
Specications
Basic Functions
Installation
•AC chargers are supplied with 6' power cable and are terminated with a NEMA #5-15
plug for 115V AC power or with a Schuko Cee 7/4" plug for 230V AC power
• DC chargers are supplied with 6’ power cable with unterminated ying leads
•Find an area within reach of a power source
•Charger can be mounted onto vertical or horizontal surfaces
•Mounting location should have space for ventilation to ensure ambient temperature does
not exceed 50°c
• Pick space such that the fan nger guard or vent holes and power cable entry are not
blocked
•Pick a dry location
•Place drill template, supplied with charger, over desired mounting location and secure
with tape
•Select four #10 or four 5mm self taping or machine thread screws, not supplied with
charger
INPUT POWER:
115VAC @ 1 Amp, 115 watts
230VAC @ 0.5 Amp, 115 watts
12VDC @ 9 AMP, 24VDC @ 4.5 Amp, 110 watts
OUTPUT: Dual Channel, 42VDC, 1 Amp Charge Rate per Battery Pack Channel
CHARGE TIME: 6 Hour Nominal
OVER-CHARGE PROTECTION: Charger shuts down if Battery Pack charge current does not drop to
150 milliamps within 9 hours
UNDER VOLTAGE DISABLE: Charger disabled if battery pack voltage is less than 6VDC
SIZE:
(W X L X H)
11-3/8"x 9-1/2"x 3-5/8"without Battery Packs | 28.9 cm x 24.1 cm x 9.2 cm
11-3/8" x 9-1/2” x 6-1/2"with Battery Pack(s) | 28.9 cm x 24.1 cm x 16.5 cm
WEIGHT: 17 lbs (7.71Kg) with two Battery packs
OPERATING ENVIRONMENT: -20˚C to 50˚C, 95% RH
NON-OPERATING
ENVIRONMENT: -40˚C to 85˚C, 95% RH
ROHS COMPLIANCE 6/6
• Microprocessor-controlled charging system, up to 6 hour charge time for RAMFAN
40V Li-Ion battery packs depending on the battery pack’s discharge state
• Charge two RAMFAN 40V Li-Ion battery packs simultaneously
• Defective battery detection

5
Electrical Connections
Installation continued
Charging Status
The charger will examine
connected batteries’ voltage
GREEN FLASHING
RED
ORANGE REDFLASHING
GREEN
Indicator Lights During Charge:
SOLID GREEN Battery pack voltage above 40VDC
Battery pack fully charged
1 SEC GREEN
FLASH
Battery pack is between 38
and 40VDC
SOLID ORANGE Battery pack is between 33
and 38VDC
1 SEC RED FLASH Battery pack between 27
and 33VDC
SOLID RED Battery pack voltage below 27VDC
½ SEC RED FLASH
Battery pack failed to charge in 9
hours, or Battery pack less than
6VDC
OFF No AC or DC input power or no
battery pack
Route and attach AC power cable plug to appropriate AC power receptacle, or route and
attach DC power cable to an appropriate 12V DC or 24V DC power block.
Three models to support various input power application: 85-260V with NEMA plug,
85-260V with Schuko plug, and 12-24DC.
AC Models: Insert AC plug into the appropriate AC power receptacle. The AC input battery
charger models are built around a universal (85 - 260AC, 50 / 60Hz) input power supply.
Only the AC plug determines the input voltage to be 115VAC or 230VAC.
DC Models: Will work with 10-30VDC input.
Charger is not equipped with a power switch and there is no reason to cycle power ON &
OFF.
Charger automatically turns ON when input power is applied to the charger. Both Battery
status LEDS will ash at a rate of two ashes per second for 10 seconds and then turn OFF
until battery pack(s) have been connected to charger.
•Determine appropriate through hole drill bit for select screws
•Drill four holes at indicated mounting locations, on the drill template and tap holes if
required
•Install screws with screw head about 1/8"above mounting surfaces
•Hang charger onto the four screws
•Tighten screws to securely hold charger in place
Batteries should not be stored for longer than 12 months without charging, to maintain
“longterm reliability.”
Refer to pages 8 and 9 for Drill Template illustration