2
Thank you for purchasing the RAMFAN® Dual Battery Charger manufactured in the USA by
Euramco Group.
For more than 30 years Euramco Group has been on the cutting edge of industrial, re, and
marine ventilation products. Each of our blower/exhausters, smoke ejectors, PPV & LSV fans and
accessories represent the nest technologies available. Every product is constructed to demanding
and exact specications for quality, performance, and reliability.
Explore our website and online catalog at www.ramfan.com and discover how RAMFAN products
can make a dierence in the eld!
All product information in the publication is based on the most current information available at the
time of printing. Euramco Group reserves the right to make changes at any time without notice.
General Safety Rules
1. SAFETY GUIDELINES
• Read and understand this manual before use.
• Always check charger, connection cable, extension cable and plug for damage and deterioration
and repair as required before use.
• Keep the cables away from heat sources, oil and sharp edges.
• Store chargers outside the reach of children.
• Charger may not be exposed to rain or condensing humidity. Exposure to rain or condensing
humidity can cause battery charger to malfunction and increase risk of shock hazards.
• Safe handling of the charger is only guaranteed if the safety and operating information are
carefully read and adhered to.
• Do not use any chargers in an explosive environment such as in the vicinity of ammable liquids
gases or dust.
2. USE AND CARE
• Take proper care of the charger. Keep an eye out for defective connections, defects and all other
conditions that may aect the device’s operation. If any damage, repair the charger before
use.
• The charger may only be used with RAMFAN Model# R2-360-AH-U battery packs. The use of other
batteries can cause damage, injury or re.
• Battery pack(s) should not be stored for longer than 12 months without charging, to maintain
longterm reliability.
• The Charger is for charging RAMFAN 40V, 6AH Li-Ion battery packs, part# R2-360-AH-U only.
• Battery packs should not be used in the vicinity of metallic objects such as paper clips, coins,
nails, screws or other small metallic objects that could bridge and short out battery connection
terminals.
• Improper use of battery packs can lead to uid leaking from the battery; avoid any physical
contact with the uid. If you accidentally come into contact with this, wash the area concerned
thoroughly with water. Seek medical assistance if the uid gets into the eyes.
3. MAINTENANCE
• No user serviceable parts. Only allow qualied individuals to maintain the charger.
This will ensure the long-term safety of the charger.
4. Alert
• Battery packs at temperatures above 105ºF / 40ºC or below 4ºF / -20ºC will not accept a charge.

3
Basic Functions ............................................................................................................................. 4
Specications................................................................................................................................. 4
Installation..................................................................................................................................... 4
Charging Status............................................................................................................................. 5
Electrical Connections ................................................................................................................. 5
Back Pack Installation ................................................................................................................. 5
Warranty......................................................................................................................................... 6
Customer Service.......................................................................................................................... 6
Disposal........................................................................................................................................... 6
EC Declaration of Conformity .................................................................................................... 7
Drill Template................................................................................................................................ 8
CONTENTS
1. SAFETY GUIDELINES
• Read and understand this manual before use.
• Always check charger, connection cable, extension cable and plug for damage and deterioration
and repair as required before use.
• Keep the cables away from heat sources, oil and sharp edges.
• Store chargers outside the reach of children.
• Charger may not be exposed to rain or condensing humidity. Exposure to rain or condensing
humidity can cause battery charger to malfunction and increase risk of shock hazards.
• Safe handling of the charger is only guaranteed if the safety and operating information are
carefully read and adhered to.
• Do not use any chargers in an explosive environment such as in the vicinity of ammable liquids
gases or dust.
2. USE AND CARE
• Take proper care of the charger. Keep an eye out for defective connections, defects and all other
conditions that may aect the device’s operation. If any damage, repair the charger before
use.
• The charger may only be used with RAMFAN Model# R2-360-AH-U battery packs. The use of other
batteries can cause damage, injury or re.
• Battery pack(s) should not be stored for longer than 12 months without charging, to maintain
longterm reliability.
• The Charger is for charging RAMFAN 40V, 6AH Li-Ion battery packs, part# R2-360-AH-U only.
• Battery packs should not be used in the vicinity of metallic objects such as paper clips, coins,
nails, screws or other small metallic objects that could bridge and short out battery connection
terminals.
• Improper use of battery packs can lead to uid leaking from the battery; avoid any physical
contact with the uid. If you accidentally come into contact with this, wash the area concerned
thoroughly with water. Seek medical assistance if the uid gets into the eyes.
3. MAINTENANCE
• No user serviceable parts. Only allow qualied individuals to maintain the charger.
This will ensure the long-term safety of the charger.
4. Alert
• Battery packs at temperatures above 105ºF / 40ºC or below 4ºF / -20ºC will not accept a charge.

4
Specications
Basic Functions
Installation
•AC chargers are supplied with 6' power cable and are terminated with a NEMA #5-15
plug for 115V AC power or with a Schuko Cee 7/4" plug for 230V AC power
• DC chargers are supplied with 6’ power cable with unterminated ying leads
•Find an area within reach of a power source
•Charger can be mounted onto vertical or horizontal surfaces
•Mounting location should have space for ventilation to ensure ambient temperature does
not exceed 50°c
• Pick space such that the fan nger guard or vent holes and power cable entry are not
blocked
•Pick a dry location
•Place drill template, supplied with charger, over desired mounting location and secure
with tape
•Select four #10 or four 5mm self taping or machine thread screws, not supplied with
charger
INPUT POWER:
115VAC @ 1 Amp, 115 watts
230VAC @ 0.5 Amp, 115 watts
12VDC @ 9 AMP, 24VDC @ 4.5 Amp, 110 watts
OUTPUT: Dual Channel, 42VDC, 1 Amp Charge Rate per Battery Pack Channel
CHARGE TIME: 6 Hour Nominal
OVER-CHARGE PROTECTION: Charger shuts down if Battery Pack charge current does not drop to
150 milliamps within 9 hours
UNDER VOLTAGE DISABLE: Charger disabled if battery pack voltage is less than 6VDC
SIZE:
(W X L X H)
11-3/8"x 9-1/2"x 3-5/8"without Battery Packs | 28.9 cm x 24.1 cm x 9.2 cm
11-3/8" x 9-1/2” x 6-1/2"with Battery Pack(s) | 28.9 cm x 24.1 cm x 16.5 cm
WEIGHT: 17 lbs (7.71Kg) with two Battery packs
OPERATING ENVIRONMENT: -20˚C to 50˚C, 95% RH
NON-OPERATING
ENVIRONMENT: -40˚C to 85˚C, 95% RH
ROHS COMPLIANCE 6/6
• Microprocessor-controlled charging system, up to 6 hour charge time for RAMFAN
40V Li-Ion battery packs depending on the battery pack’s discharge state
• Charge two RAMFAN 40V Li-Ion battery packs simultaneously
• Defective battery detection

5
Electrical Connections
Installation continued
Charging Status
The charger will examine
connected batteries’ voltage
GREEN FLASHING
RED
ORANGE REDFLASHING
GREEN
Indicator Lights During Charge:
SOLID GREEN Battery pack voltage above 40VDC
Battery pack fully charged
1 SEC GREEN
FLASH
Battery pack is between 38
and 40VDC
SOLID ORANGE Battery pack is between 33
and 38VDC
1 SEC RED FLASH Battery pack between 27
and 33VDC
SOLID RED Battery pack voltage below 27VDC
½ SEC RED FLASH
Battery pack failed to charge in 9
hours, or Battery pack less than
6VDC
OFF No AC or DC input power or no
battery pack
Route and attach AC power cable plug to appropriate AC power receptacle, or route and
attach DC power cable to an appropriate 12V DC or 24V DC power block.
Three models to support various input power application: 85-260V with NEMA plug,
85-260V with Schuko plug, and 12-24DC.
AC Models: Insert AC plug into the appropriate AC power receptacle. The AC input battery
charger models are built around a universal (85 - 260AC, 50 / 60Hz) input power supply.
Only the AC plug determines the input voltage to be 115VAC or 230VAC.
DC Models: Will work with 10-30VDC input.
Charger is not equipped with a power switch and there is no reason to cycle power ON &
OFF.
Charger automatically turns ON when input power is applied to the charger. Both Battery
status LEDS will ash at a rate of two ashes per second for 10 seconds and then turn OFF
until battery pack(s) have been connected to charger.
•Determine appropriate through hole drill bit for select screws
•Drill four holes at indicated mounting locations, on the drill template and tap holes if
required
•Install screws with screw head about 1/8"above mounting surfaces
•Hang charger onto the four screws
•Tighten screws to securely hold charger in place
Batteries should not be stored for longer than 12 months without charging, to maintain
“longterm reliability.”
Refer to pages 8 and 9 for Drill Template illustration

6
The battery charger will hold and charge two battery packs at one time.
Charger will function with one or two battery packs installed.
Align battery pack with holder and drive battery into position until a loud click is heard.
Attach charging cables to the battery pack(s).
Battery charger will determine if batteries are attached, measure & report battery charge/
fuel level, and initiate a charge cycle.
Typical charge time for a fully discharged battery is approximately 6 hours. Partially
discharged batteries will take less time.
• Charger is not supplied with an ON / OFF power switch.
• Charger is active as soon as input power is applied.
GREEN LED lights ash 20 times over a 10 second period when power is rst applied to the Dual
channel Battery Charger.
• LED lights will remain OFF until a battery pack is connected to the charger.
• Battery pack charge status will be reported by the LED status lights.
NOTES:
Battery Pack Installation
Battery Charger comes with a 12 month limited warranty. This does not cover damage
due to improper handling. For information please visit www.RAMFAN.com.
The customer service department will answer your questions regarding repairs and
maintenance for your product as well as regarding spare parts and operation. You can also
nd further information at www.RAMFAN.com.
Warranty
Customer Service and Advice
Disposal
Charging devices, accessories and packaging should be recycled in
an environmentally-friendly manner.
Only for EU countries: Do not dispose of charging devices in
household waste. In accordance with the European Directive
2012/19/EC on Waste Electrical and Electronic Equipment and its
implementation into national law, unserviceable chargers should
be collected separately and recycled in an environmentally-friendly
manner.
Environmentally Safe Battery Disposal
Battery pack(s) contain Li-ion, a toxic material. All toxic materials must
be disposed of in a specied manner to prevent contamination of the
environment. Before disposing of damaged or worn out Lithium-ion battery
packs, contact your local waste disposal agency, or the local Environmental
Protection Agency for information and specic instructions. Take the batteries
to a local recycling and/or disposal center, certied for Li-ion disposal.

7
EC Declaration of Conformity
DECLARATION OF CONFORMITY
BATTERY CHARGERS
Year of Manufacture: 2018
Manufacturer: Euramco Safety, Inc.
2746 Via Orange Way
Spring Valley, Ca. 91978 USA
Equipment Description: R2C-5500AC – Universal AC Input, 42VDC @ 2 Amp Output
R2C-5500AC230 – Universal AC Input, 42VDC @ 2 Amp Output
R2C-5500DC – 12-24VDC Input, 42VDC @ 2 Amp Output
BPV-12CE – 12V Battery Charger (EURO)
European Directives: 2006/42/ EC – Machinery Directive
2014/30/EU – EMC Directive
2014/35/EU – Low Voltage Directive
2011/65/EU – Restriction of Hazardous Substances Directive
Standards to which this Conformity is Declared:
BS EN ISO 13857:2008 – Safety Distances
BS EN ISO 12100:2010 – Safety Machinery
BS EN 6100-6-4:2007+A1:2011 – EMC Industrial Generic Emission
BS EN 6100-6-2:2005 – EMC Immunity/Industrial Environments
Euramco Safety, Inc. hereby declares that the equipment described above conforms to the relevant
Essential Health & Safety Requirements of the European Machinery Directive 2006/42/EC, and the
Additional Directives and Standards listed above.
DATE 11/28/2018
___________8/21/2018_________________

8
127mm
5.000in
AIR FLOW
AIR FLOW
AIR FLOW
261.9mm
10.31in
191.9mm
7.56in
10.2mm
.400in
5.6mm
.221in
ACCURATE BEFORE DRILLING
SET BACK 2" FROM
4 PLACES
MAKE SURE THAT DIMENSIONS ARE
DRILL FOR #10 OR M5 SCREW
FULL SCALE TEMPLATE.
WALL MINIMUM
POWER
CABLE
DWG. NO.
Euramco Safety Inc.
R2C DRILL TEMPLATE
PART NO.
DWG-R2TEMPLATE
Description
FIDUCIAL TARGETS
Drill Template
Half scale size of template

9
127mm
5.000in
AIR FLOW
AIR FLOW
AIR FLOW
261.9mm
10.31in
191.9mm
7.56in
10.2mm
.400in
5.6mm
.221in
ACCURATE BEFORE DRILLING
SET BACK 2" FROM
4 PLACES
MAKE SURE THAT DIMENSIONS ARE
DRILL FOR #10 OR M5 SCREW
FULL SCALE TEMPLATE.
WALL MINIMUM
POWER
CABLE
DWG. NO.
Euramco Safety Inc.
R2C DRILL TEMPLATE
PART NO.
DWG-R2TEMPLATE
Description
FIDUCIAL TARGETS

10
NOTES

11

SM-R2C REV D
120718
MADE IN THE USA
Use with all
US Firefighting
literature
USA
2746 Via Orange Way
Spring Valley, CA 91978 USA
Toll Free: (800) 472-6326
Phone: +1 (619) 670-9590
Fax: +1 (619) 670-7345
LUXEMBOURG
1 Rue Edmond Reuter,
5326 Contern, Luxembourg
Phone: +352-621377200
Fax: +352-26008056
MIDDLE EAST – UAE
Jebel Ali FTZ, Dubai
Phone: +1 (619) 670-9590 x114
Fax: +1 (619) 670-7345
CHINA
No. 128, HeZhou Road, JiaoChuan Street,
ZhenHai District, Ningbo, China 315207
Phone: +86-574-87979390
Fax: +86-574-87979391
This manual suits for next models
2
Table of contents
Other RAMFAN Batteries Charger manuals