Rcom MARU DELUXE Hatcher & Brooder MX-100HBD User manual

MARU DELUXE Hatcher & Brooder (100 / 380)
MX-100HBD / MX-380HBD
Ver. 2.5
Love of life begins with "Rcom"
DIGITAL EGG INCUBATOR
USER'S MANUAL

5. How to Clean
(1) Instructions for Disassembling and Cleaning
16 ~ 17
Successful hatching depends on many numbers of factors. Neither Autoelex (Rcom) nor its global
distributors and vendors can be held responsible for loss of life or property damage caused by user
neglect, alteration, modification or painting, change of use or power failure. To avoid errors, mishaps
and danger, carefully check this User Manual before initial use. Also please check the manual regularly
to ensure your operation of the machine is correct.
1. Introduction
3 ~ 6
(2) Safety precautions
(4) Name & Function of Operation Parts
(3) Identification of Parts and Composition
6. Product Information
(1) How to Service your Maru H&B Replacing the Fuse, General maintenance
18 ~ 21
(2) Troubleshooting(FAQ)
(3) Specification
4. MARU H&B Function Settings
(1) Return to Factory Settings
13 ~ 15
(2) Temperature and Humidity Settings
(3) The Abnormal High and Low Alarm Settings
(5) Sound ON /OFF
(4) How to change between Centigrade and Fahrenheit Temperature units
(6) Room Light ON/OFF Setting
2. Before use
(1) What is an Incubation Room?
7 ~ 8
(2) How to install this MARU H&B
3. Hatching and Brooding
9 ~ 12
(1) Preparing for Hatching and Brooding / How to Start Hatching and Brooding
(2) Humidification, and how to Terminate Hatching and Brooding
(3)
Humidity and Condensation principles, Air Flow considerations, and Post-Hatch maintenance, Dew Condensation
Introduction
Hatching and
Brooding
Product Information
Function Settings
How to Clean
Before use
(1) Rcom MARU H&B Introduction
DIGITAL INCUBATOR
2
Contents
How to use Rcom MARU DELUXE Hatcher & Brooder 100 / 380
Caution : Caution mark against a fault that can cause damage, trouble, or failure of incubation.
Tip : References or useful suggestions in using Rcom product
Mark Explanation
Warning of actions which may be dangerous or cause damage to the incubator.
Prohibited.
Do not disassemble.
Do not touch.
It is necessary to keep.
Remove the power cord from outlet.
Ground Connection for preventing electric shock.
* Read the manual completely before use.

Features of Rcom MARU H&B
[Main Function]
* Convenient jog dial operation for optimized user interface
* Integrated simple control panel (superior maintenance)
* FND display for easy recognition of incubation state
* Artificial intelligence electronic control system by Rcom technology
* Precise temperature and humidity sensor produced by Sensirion, Swiss (ver. 3rd Generation of Sensirion, Swiss)
* Transparent double insulated viewing window
* Sliding vent to in the chamber
* Dependable temperature by Rcom optimum air flow technology
* Innovative PTC Heating Type humidifier eliminates bacteria from humidity reservoir
* Built-in water level sensing switch automatically detect the water level inside the humidifier and alarm water refill is required
* Increased temperature stability and energy efficiency due to high-density insulated body developed by Rcom
* Built-in ‘open door’ micro-switch detection
[Useful Function]
* Degree C / degree F interchangeable
* Built-in brooding compartment for convenient management
* Separate humidifier not required due to built-in humidifier unit within the device
* Warning & display function of abnormal temperature caused by ambient temperature fluctuation
* Incubation data memory and alarm function in case of blackout
* Equipped with water nipple in front for efficient water supply
* Maximized egg setting available with the universal egg basked (Sold Separately)
* Equipped with upper cover for convenience of cleaning or maintenance after hatching
* Built in LED dome-light for ease of viewing when door is open
* Built-in internal air filter for equipment protection
[Sold Separately]
* Universal Egg Basket and ABS Divider, Basket Support
Firstly, we sincerely thank you for purchasing Rcom MARU H&B.
It has been designed to analyze airflow using built in digital technology to maintain an optimal environment within the
MARU H&B cabinet. The incubation parameters are controlled using purpose built control systems coupled with high end
sensors, all in order to permit optimum results. However, best results occur when the user, couples personal knowledge
of the machine and of incubation and hatching along with observation skills with the Maru H&B sensing, automation
and control systems. The machine needs your help, good breeding flock, healthy flock diet, fertile eggs , reasonable
incubation room environment and a ‘clean’ power supply in order to provide excellent results. User’s knowledge of the
machine and manage the MARU H&B are very important. Certainly, the Maru provides an optimal incubation environment
but parameters need to be managed, i.e. temperature and humidity depends on egg species, environment, and capacity.
Moreover, the Rcom MARU H&B has been carefully designed to provide an optimal setting and or hatching environment,
therefore, before using the incubator, we strongly recommend that you read the manual carefully.
Rcom MARU H&B
DIGITAL INCUBATOR
(1) Rcom MARU Introduction
1. Introduction
3

1. Introduction (2) Safety Precautions
DIGITAL INCUBATOR
4
Electrical hazards Be careful the details below when you use.
Setting Cautions Be careful the details below when you use.
Cleaning Cautions Be sure to disconnect the electric cord from the outlet
before cleaning.
Do not pull the cord when
taking out the power cord, and
keep wet hands away from
connecting plug.
Do not use a damaged power
cord or loose outlet.
▶ Risk of electric shock or fire.
▶ Risk of electric shock or fire.
Do not insert multiple
connecting plugs in an outlet.
▶ Risk of fire or electrical
overload.
Never pull the plug out of the
outlet during the incubation
period.
▶Incubation will be interrupted.
Do not twist or crush electric
cord.
▶ Risk of electric shock or fire.
Do not install under the direct
sunlight.
Do not install in dusty or dirty
environment.
▶ Risk of fire or interference
with the incubation process.
▶ Risk of damage or fire within
the incubator.
Do not install in excessively
cold or hot conditions,
cigarette smoke, etc.
Do not install in moist or
humid environment.
▶ Risk of interference with
the incubation process.
▶ Risk of fire or electric shock.
Do not use any other
non-standard parts except
those provided.
▶ Risk of damage or hatching
failure.
Clean the machine by a soft
cloth with a neutral detergent.
Do not use chemicals like wax,
benzene, alcohol, thinner,
aromatic, or lubricant, etc.
Brush away dust on the plug
with a dry cloth.
For special cleaning of inner
part per year, contact to the
service center.
▶ If you don't clean the inside of
incubator for a long time, dust
can cause some trouble or a fire.
Install away from heat
sources.
▶ Risk of damage to the
incubator case and
interference with the
incubation process.
Ensure that the incubator is
installed on a stable surface
away from edges.
▶ Risk of damage to incubator
and eggs and user from
accidental knocks or drops.
Do not cover the ventilating
opening.
▶ Inner temperature can rise,
interrupting incubation. ▶ Risk of knocking the machine
or accidental interference with
the controls.
Children should be supervised
to ensure that they do not play
with the appliance.
If the machine requires repair
disconnect from the power
supply and please contact to
your service center.
Please ensure that no small
objects get into
the holes on the machine.
▶Risk of electric shock or fire.
Do not disassemble or modify
the incubator in any way.
▶ Risk if electric shock or fire.
If the machine sounds
strange or emits smoke
contact your service center.
▶Risk of electric shock or fire.
Clean the machine
thoroughly before storing.
Do not place water container
on the machine.

Brooding Box Air Filter
MX-380HBD 12EA / 24EA MX-380HBD 36EA MX-100HBD 4EA
MX-380HBD 4EA
Air Filter
1. Introduction
DIGITAL INCUBATOR 5
(3) Identification of Parts
and Composition
Serial NO is located on the upper front cover. (ex. RCM0000000)
is a product specific number.
Identification of Parts
Air Vent (Front)
For connecting power cord.
Power Connecting (the rear)
Jog Dial
Nipple for water hose
Insulation Board
Temp, Humi. sensor/
Door detecting micro switch
Tray (MX-380HBD dedicated)
Universal Egg Basket
(Sold Separately)
(Sold Separately)
Air inlet vent
Air Vent (Front)
refer to control panel
function description
Control Panel/
Display Window
LED Room Light
Door
Dual structured
insulated window
Brooding Room
Hatching Space
Temporary space
for hatching
Temporary space
for brooding
Rubber foot, Door Guide
Basic Components
Driver
Manual Power Cord Silicon Tube : 1.5M (Diameter: Ø4*6)
Sold Separately
Universal Egg Basket / Basket Support ABS Divider Spinning Wheel, Bracket
Pieces : 18EA
(2EA)(4EA) (2EA)
* MX-380HBD model image

①Heater Operation Lamp :Light on when working
②Temp. Display : Current Temperature Display
③Humidity Display : Current Humidity Display
④
Pumping System Operation Lamp
: Light on when working
⑤Jog Dial :Press and turn around to left and right
- Function setting mode will appear when pressed for 3 seconds
- Temp. and humidity can be checked when pressed for 1 second
⑥Room Light Button :To turn the light on and off with-in the equipment
⑦Function Table :Function can be selected in order by using the jog dial
⑧Outage Notification : Blinks during power outages.
(Release button: press the jog dial once)
⑨Warning Lamp :Turned on in case there’s any problem with temperature
⑩Water Supplement Lamp :Blinks with water shortage (”Water empty signal” will be alarmed every 10 seconds)
●Names and components of each part
Rcom MARU DELUXE H&B 100 / 380
1. Introduction (4) Name & Function of
Operation Parts
DIGITAL INCUBATOR
6
Name & Function of Operation Parts

▶To set up the Air Filter, please open the Door, and look at the ceiling inside of the machine. You can set up the
Air-filter as shown in the picture below.
Clean the air filter every 2 weeks .
[Refer to the Page 17]
2. Before use (1) What is an Incubation Room?
(2) How to install this MARU H&B
DIGITAL INCUBATOR 7
What is an Incubation Room?
The Incubation Room is a confined space for setting and operating an MARU H&B efficiently.
An Incubation Room environment has a considerable effect on hatch rate. Controlling the MARU H&B
environment is recommended; there should be little noise or vibration and constant temperature ranging
upwards from 28℃(82.4℉) with small variation in temperature. For optimum performance, pay attention
that your MARU H&B isn’t exposed to temperature drops compared with daytime. Do not directly exposed the
MARU H&B to sunlight during daytime. also, please MARU H&B where direct wind from air-conditioner not to reach.
If you set a high temperature, condensation will occur and may causes water to leak from the machine and
it which is not a technical problem. You need to keep temperature between 28℃(82.4℉).
Do not place water container on top
of the machine. It may flood the
humidity nit.
How to Install the this MARU H&B
▶Please set the machine horizontally on a stable, tallish
table (50[cm] or above)
▶Ensure the machine is completely level, so the door can
close completely.
▶Connect silicon tubing onto the nipple of machine, and
the other end of silicon tubing into a water container.
50cm
WATER IN
Using tap water or underground water
instead of distilled water in this unit's
humidification device will cause serious
debris (scale) to develop. In this case,
the inconvenience of frequent cleaning
will occur and when left alone, may
become the cause of malfunction or
breakage. If you have any questions
regarding such problems,
please contact the place of purchase
and failure of the device due to the
consumer negligence(due to non-cleaning), even if it occurred with in the free A/S period, repair
charges might occur when repairing, so use of distilled water is highly recommended.
*MX-100HBD*MX-380HBD

▶When the power cord is plugged in and turned on the digits on the temperature and humidity FND appears,
then Temperature and Relative Humidity will increase a little. (Their default value is respectively : 37.0℃(98.6℉)
and RH 60%) A initial smell may be noticed this is to be expected.
▶Please check and refill distilled water every 2 days during incubation. Or as needed
(If the water tank is small, please check every day.)
※To turn off the Humidification Function : Set humidity under RH 20%.
▶For this equipment, divider for the universal tray is not required. Please remove the dividers.
Do not connect power supply before the machine is assembled completely.
Risk of electric shock.
If you use the machine without adding humidification water or intend to incubate eggs at low humidity under
RH 20%, you must stop the humidification function. Please turn off the humidity function if there is no water
available otherwise the humidity unit will fail, making the machine unuseable. When using this function
(disabled humidification) the Water Empty Led and the related alarm from the control panel are turned off.
[Refer to the page 13]
Using tap water or underground water instead of distilled water in this unit's humidification device
will cause serious debris (scale) to develop. In this case, the inconvenience of frequent cleaning
will occur and when left alone, may become the cause of malfunction or breakage. If you have any
questions regarding such problems, please contact the place of purchase and failure of the device
due to the consumer negligence (due to non-cleaning), even if it occurred with in the free A/S period,
repair charges might occur when repairing , so use of distilled water is highly recommended.
2. Before use
3. Hatching and Brooding
(2) How to install this MARU H&B
(1) Preparing for Hatching and Brooding /
How to Start Hatching and Brooding
DIGITAL INCUBATOR
8
The device can be broken or injured due to weight when setting up or laying down the machine, so remove
the egg basket or trays inside the device before assembling.
▶ⓐ: the front - brake-type wheel x 2
ⓑ: the rear - brake free-type wheel x 2
▶Cautiously, lay the machine down :
bracket-wheel-screw in sequence
ⓐfor the front 2wheels, assemble brake-type wheel
ⓑfor the rear 2wheels, assemble brake free-type wheel
Once the assembly done, put up the assembled machine
with care.
Pieces : 18EA
(2EA) (Bracket 4EA)(2EA)
[ Rotary wheel assembly method ] - Rotary wheels are sold separately
Sold Separately
Preparing for Hatcing and Brooding

3. 부화
※The artificial intelligence system memorizes and classifies ambient conditions to assist in keeping optimum
temperature; temperature can move up slowly at first stage.
※Power Outage notification: If power fails during operation or the power cord is reconnected after being removed
for some reason ⓐ( " . " ) will blink.
▶Current temperature and humidity will appear on the display panel and it will slowly reach the set value after
1~2 hours.
▶Eggs in the “last stage of hatching” should be taken from
the incubator (or setter) and put on the H&B cabinet shelves.
If there is an extra universal egg basket, it could be used
as a cover, as shown in the picture.
▶Put the eggs in the universal egg basket, and basket
supports into the four corners, turn an empty universal tray
upside down, plug into the basket supports to cover the
tray that contains your eggs.
▶Insert the assembled universal trays into each of the shelves.
Quick Start : If you just connect the power plug and turn power on, the machine automatically starts hatching
and brooding with factory setting. [Factory setting: Temperature 37.0℃(98.6℉), Humidity RH 60%]
▶After version indication, buzzer sounds for about 15sec.
At the same time, present temp. & humidity is displayed
and power failure alarm indication ( " . " ) ⓐis blinking.
▶Press Jog dial in to remove buzzer and alarm indication.
(Buzzer will cease automatically after 15sec.)
▶For the first two seconds, after power on, FND blinks and
the pump starts working (until the internal humidification
water tank is filled : In case of water shortage the pump
runs for 2min.) and for another one second, the version
number will be displayed on FND.
How to Start Hatching and Brooding
Test the machine to be sure that the machine works
without any problem before placing eggs in the machine.
Please ensure you remember how to use the machine
and maybe re-read instructions.
Be sure to close the door completely,
if not, the temperature and humidity will not be controlled.
Please check if the machine’s floor is wet or not, it
should be dry, otherwise the machine may not reach
the normal temperature.
(Do not place water container on top of the machine.)
Universal Egg Basket
Basket
Support
3. Hatcing and Brooding
(1) Preparing for Hatching and Brooding /
How to Start Hatching and Brooding
DIGITAL INCUBATOR 9
* MX-380HBD model image

▶All kinds of bird need over RH 60% humidity during the period prior to hatching.
Humidification
3. Hatcing and Brooding
(2) Humidification, and how to
Terminate Hatcing and Brooding
DIGITAL INCUBATOR
10
▶How to turn humidification off : When you don't need the humidification function with your working machine,
you can turn off by setting under RH 20% in the humidity setting mode.
The mark " -- " appears on FND and the humidity function stops.
[Refer to the Page 13]
▶Indication of water shortage : When the sensor detects low water level, water empty lamp is turned on.
Lasting water shortage causes turning water empty lamp on, blinking of humidity
working lamp and alarm ringing.
In case of water shortage, it works. When the inside of the machine is filled with water, the pump motor works
for 0.5 second. (Check motor working sound)
▶Pumping Motor Test Method: During the operation of the machine, pressing the jog dial 3 times shortly will operate
the pump motor.
Please turn off the humidity unit if the unit is empty water otherwise, humidity unit will be broke or you may
not no longer use the unit. So please turn off the humidity unit. [Refer to the page 13]
Using tap water or underground water instead of distilled water in this unit's humidification device
will cause serious debris (scale) to develop. In this case, the inconvenience of frequent cleaning
will occur and when left alone, may become the cause of malfunction or breakage. If you have any
questions regarding such problems, please contact the place of purchase and failure of the device
due to the consumer negligence (due to non-cleaning), even if it occurred with in the free A/S period,
repair charges might occur when repairing , so use of distilled water is highly recommended.
▶No power switch for the machine.
The power cord should be unplugged to turn the machine
off after hatching and brooding.
▶Rcom MARU do not need to be initialized after hatching
and brooding.
When you need the same condition as the previous set,
all you need to do is to plug in your machine.
How to Terminate Hatching and Brooding
Power Cord
OFF

▶When hatching, humidity should be relatively high to prevent the thin membrane from drying out or hardening
before hatching.
▶When hatching, it's recommended not to open the door often.This is because if you open the door often humidity
will be rapidly decreased and it will take a long time to regain the proper humidity.
▶It's very important to maintain humidity higher 1~2 days before hatching than the early and middle incubation
periods. Humidity requirements during incubation are RH 45~55% for waterfowl, RH 40~45% for poultry and
RH 35~45% for parrot, in general. One day before hatching, all kinds of birds need about RH 65% humidity
and sometimes need higher than that. However, in areas of high ambient humidity, lower levels of humidity may
be needed during incubation.
▶Air Controlling Lever : Outer fresh air can be flowed into machine inside without affecting insulation. When eggs
start hatching, open air controlling lever either fully or half-open.
▶If the temperature where machine installed is high, it will effects to tmachine setting temperature.
In this case, you are able to adjust temperature by Air ventilation on the top of machine.
machine internal temperature is 37℃(98.6℉) or more, and hatching room temperature is below 28℃,
in that case, RH 70% humidity is may not be able. The difference of ±5% humidity value may occur
from the humidity sensors difference, and there are no problems at hatching.
If you set high temperature, condensation will occur the near Air Vent and may causes licking water from the
machine and it is not a technical problem.
DIGITAL INCUBATOR
3. Hatcing and Brooding
(3) Humidity and Condensation principles,
Air Flow considerations, and Post-Hatch maintenance,
Dew Condensation
11
Humidity and Condensation principles, Air Flow considerations
1/4 open 1/2 open close wide open
You can adjust
Air Ventilation

* MX-380HBD * MX-100HBD
Hatching Room
(Basket/Divider set:
sold separately)
Brooding Room
Brooding Room
or
Hatching Room
(Basket/Divider set:
sold separately)
▶Feed should be regularly replaced with new and uncon
taminated feed. For young chicks, yolks from boiled eggs
should be crumbled, mixed with grains or vegetables and
fed for good results. As there are some differences in chick
feed for each kind of bird, it is desirable to obtain useful
information about the chicks before hatching. (Please
refer to Rcom website for helpful information on birds)
If you put too much water into drinkers, chicks could
fall into the water bowl and their wet feathers can cause
hypothermia, leading to the death of the chicks.
In this case, dry the wet feathers with a hair dryer.
▶Chicks incubated from the hatching Room should be
relocated to the brooding space located in the lower section
of the device. The temperature for the H&B cabinet should
normally be 37℃(98.6℉)
▶The H&B cabinet should always be clean. By lining the
brooding room with sawdust, wood shavings or finely cut
paper, chances of contamination can be reduced.
Also, the opening of the water bowl should be covered in
a shape of “+” with a tape. (To prevent chicks from falling
into the bowl)
▶Temperature management : Start from 37℃(98.6℉),
lowering the temperature by 1~2℃(1.8~3.6℉) every
week to adapt the chicks to the external temperature.
Chick Observation is important during brooding as is
cleanliness.
▶Humidity Management : Even if the humidifier is not turned
on, the humidity of the H&B cabinet will be high due to
hatching chicks. Please open the Air Vent to the maximum
setting.
▶Clean all the contaminants off the cabinet floor and replace
sawdust, wood shavings or finely cut paper.
[ H&B cabinet Cleaning ]
(3) Humidity and Condensation principles,
Air Flow considerations, and Post-Hatch maintenance,
Dew Condensation
3. Hatcing and Brooding
DIGITAL INCUBATOR
12
Post-Hatch maintenance
Dew condensation is natural phenomenon which can be occurred
when machine inner temperature is big different from outer temperature.
So, water can leak from the machine during humidification, which is normal.
Appropriate machine internal temperature is between 28
℃
(82.4
℉
).
Dew Condensation
Water Bawl

DIGITAL INCUBATOR
(1) Return to Factory Settings
(2) Temperature and Humidity Settings
4. MARU H&B Function Settings
13
Temperature Settings
▶Unplug power cord. Reconnect power plug whilst
simultaneously pressing the jog dial. Then, "rSt AL" will
be indicated in the display, now the MARU is returned to
factory settings. (Default setting)
▶This function is for return machine to factory setting.
Return to Factory Settings
Humidity Settings and Humidifier Device OFF method
▶When jog dial is pressed for 3 seconds from the initial
setting, “tEP” (Temperature) is displayed for 0.5 seconds
and the temperature setting will blink.
▶When the temperature setting is blinking, turn the jog dial
to left or right to increase or decrease the temperature
by 0.1°C. [Default Value: 37.0℃(98.6℉)]
▶When the desired setting is reached, press the jog dial
once to save the set temperature value, now next phase,
humidity setting’s “rH” (humidity), will display for 0.5
seconds on the display window and the set value will blink.
※If you do not wish to change the setting values for the remaining functions in the next steps, press the jog dial for
3 second and the standard values will be entered , the SET display and menu will discontinue.
※If you do not wish to change the setting values for the remaining functions in the next steps, press the jog dial for
3 second and the standard values will be entered , the SET display and menu will discontinue.
Factory Setting Display
Step 1
Step 2
Humidity Function OFF
Step 3
Step 4
▶From the temperature setting, press the jog dial once and
“rH” (Humidity) will be displayed for 0.5 second and humidity
display will blink.
▶When the humidity display blinks, turn the jog dial left or
right to increase or decrease the humidify by 1%.
[Default Value: RH 60%]
▶If, when the humidify display is blinking, and you set the
RH below 20%, (set by turning the jog dial to the left), the
humidity function will now be “OFF” and will be displayed
as ⓐon the display panel.
The temperature and humidity level is optimized
according to the international standard at the time of
shipping. It could be recalibrated by the user if the user
wishes to do so, but this is not recommended.
When in need of adjustment, please refer to our homepage (www.Rcom.co.kr → Information → User Manual
Category) or contact the place of purchase. Commercially available thermometer and hygrometers may have
drastic measurement deviations, so it is recommended to use thermometer and hygrometer designated for
this purpose. [Designated Thermometer and hygrometer – Refer to Rcom Homepage]
▶When the desired setting is reached, press the jog dial once
to save the set humidity value and sequence will move to
the next phase i.e Abnormal High Temperature alarm. “HI”
(Abnormal HIgh Temperature Alarm), will display for 0.5
seconds on the display window and the set value will blink.

(3) The Abnormal High
and Low Alarm Setting
4. MARU H&B Function Settings
DIGITAL INCUBATOR
14
※If you do not wish to change the setting values for the remaining functions in the next steps, press the jog dial for
3 second and the standard values will be entered , the SET display and menu will discontinue.
※If you do not wish to change the setting values for the remaining functions in the next steps, press the jog dial for
3 second and the standard values will be entered , the SET display and menu will discontinue.
The Abnormal High Alarm Settings
※It shows that the set temperature value is approximately 3℃(5.4℉)
higher than the Maru incubator’s incubation chamber(the Cabinet).
ex :
▶When the desired setting is reached, press the jog dial once
to save the set alarm value and the setup sequence will
move to the next phase i.e Abnormal Low Temperature Alarm.
“LO” (Abnormal LOw Temperature Alarm), will display for
0.5 seconds on the display window and the set value will blink.
▶When the alarm set value is blinking, turn the jog dial left
and right to increase or decrease the value by 1℃.
[Default Value: 2℃ (3.6℉)]
What is the abnormal high temperature alarm?
It is a function that lets the users know that the cabinet temperature increased due to unusual external
temperatures, when the temperature of the incubating cabinet increases beyond the set value due to increased
internal temperature , this alarm will ring along with the “HI” display and temperature difference (ex: 3 degrees).
After that, even if the temperature returns to normal, the jog dial needs to be pressed to cancel the alarm,
otherwise the alarm will continue to sound along with the blinking display.
Step 5
Step 6
The Abnormal Low Alarm Settings
ex : ※It shows that the set temperature is 4℃(7.2℉) lower than the
actual cabinet temperature of the machine.
▶When the desired setting is reached, press the jog dial
once to save the set alarm value and the setup sequence
will move to the next phase , that is Celsius/Fahrenheit.
“C,F” (Celsius/Fahrenheit), will display for 0.5 seconds on
the display window and the set value will blink.
Abnormal Low Temperature :
In case of abnormal low temperature “LO” will be displayed on the display window and the procedure will be
the same as the abnormal HIgh temperature
▶From the Abnormal HIgh Temperature Alarm setting, press
the jog dial once and “LO” (abnormal LOw temperature
alarm) will be displayed for 0.5 second and the temperature
display will blink.
▶When the alarm set value is blinking, turn the jog dial left
or right to increase or decrease the value by 1℃.
[Default Value: -3℃ (-5.4℉)]
Step 7
Step 8
▶From the humidity setting, press the jog dial once and
“HI” (abnormal HIgh temperature alarm) will be displayed
for 0.5 second and temperature display will blink.

Room Light ON/OFF Setting
Leaving the lamp on for a long period of time is not
good for hatching and brooding.
▶When you press the cabinet light button, you can ON/OFF
the room light. [Default Value : OFF]
▶When the door is open, the cabinet light turns on, when
the door is closed, the light is OFF.
DIGITAL INCUBATOR
4. MARU H&B Function Settings
(4) How to change between Centigrade and
Fahrenheit Temperature units
(5) Sound ON /OFF
(6) Room Light ON/OFF Setting
15
How to change between Centigrade and Fahrenheit Temperature units
▶When the desired setting is reached, press the jog dial
once to save the set value and the setup sequence will move to the next phase of sound. “S.nd” (Sound), will
display for 0.5 seconds on the display window and the set value will blink.
▶From the abnormal LOw temperature alarm setting, press
the jog dial once and “C.F” (Celsius/Fahrenheit) will be
displayed for 0.5 second and LED for “C” will blink.
▶By turning the jog dial left or right, LED light for “C” or “F”
will blink accordingly [Default Value : ℃]
℃
= 5/9 (
℉
- 32)
※If you do not wish to change the setting values for the remaining functions in the next steps, press the jog dial for
3 second and the standard values will be entered , the SET display and menu will discontinue.
Step 9
※If you do not wish to change the setting values for the remaining functions in the next steps, press the jog dial for
3 second and the standard values will be entered , the SET display and menu will discontinue.
Sound ON /OFF
▶From the “C/F” change setting, press the jog dial once
and “S.nd” (Sound) will be displayed for 0.5 second and
the set value will blink. [Default Value : ON]
▶ When you turn the jog dial to the left or right, “S.ON” ↔ ”S.OFF” will be displayed respectively.
▶After setting the desired setting, press the jog dial once to save the setting and the settings sequence is complete.
ON OFF
Step 10

DIGITAL INCUBATOR
(1) Instructions for
Disassembling and Cleaning
5. How to Clean your MARU H&B
16
▶If you turn the machine off and then leave the machine
door closed after high humidity hatching and brooding,
accumulated moisture inside the machine evaporates and
sticks to electric and electronic circuits. This could cause
problems, be sure to open the machine door and completely
remove moisture inside of machine.
Instructions for Disassembling and Cleaning
Power cord must be removed from the outlet of the
machine.
▶Remove all the remaining water from the
humidity unit.
▶As shown in the picture, unscrew 6 screws
located in the corners of the machines
cover with the screwdriver and open the
cover.
[ Cleaning the Controller Unit ]
If there are any dirty substance(scale)
in the humidifier unit and pan, it must
be removed.
▶dirty substance(scale) can form in the
humidity unit and pan should be removed
by using a vacuum cleaner, brush and/or
further cleaning aided by vinegar.
If a lot of dirty substance(scale) has
formed in the humidifier unit, soaking
it in vinegar overnight will neatly clean
the humidifier unit.
If a lot of scale has formed it is likely you
are not using distilled water, please use
distilled water as it prolongs machine life.
Power Cord
OFF
humidity unit
Vinegar
* MX-380HBD model image

Air filter should be cleaned every 2 weeks.
[ Air filter Cleaning ]
▶Open the H&B door, remove the air
filter located in the cabinet ceiling
moving it in the direction of the arrow,
clean with water and dry. It is
recommended that the air filter should
be changed once every 6 months to
1 year. (Depending on Use)
▶Follow the reverse disassembly process for reassembly.
DIGITAL INCUBATOR
5. How to Clean your MARU H&B
(1) Instructions for
Disassembling and Cleaning
17
[ Cleaning the Temperature,
Humidity sensor ]
▶This sensor part lies in upper part inside
the machine, behind the controller
assembly but in front of the fan/heater unit.
Occasionally, fluff, feathers, dirt (Dander)
or water disturbs the accurate measurement
of temperature & humidity. Please clean Dander
away with a soft brush.
▶Reassemble in the reverse order of disassembling and
store machine safely in a cool dry place.
Feather Dander and dust can clog up or foul circulation fans; this can make the fans noisy and also destroy
the fans. It is very important to clean your machine, for maintenance reasons and also to increase incubation
success.
Be careful not to allow moisture into the power connecting
parts on the rear of the machine.
Do not clean the machine with benzene or thinner.
There is a risk of transformation or dis-colorization.
After several hatching, dust or bird feathers (Dander) can build up in the mechanisms, controller and humidity
unit and cause incorrect operation or malfunction. So, ensure you clean the incubator carefully after each
hatch. (The life span of the humidity unit can be reduced when used without cleaning.)
[ Cleaning the Incubator Cabinet]
▶After hatching, remove egg basket and divider inside of machine, and clean the inside with vacuum cleaner.
Tiny dust should be removed with brush again.
▶Clean the egg basket and dividers, brooding box with
water and an antiseptic solution, and then dry naturally
or operate machine temporary to dry them.
*MX-100HBD*MX-380HBD

In case hatching rate
is low
▶Inspect the egg to check possibility
of egg surviving.
▶Disinfect the machine.
▶Check all settings of machine.
Especially, check them focusingon the
temperature.
▶Review care of health of mother bird.
▶ When the egg is an unfertilized egg.
▶ Getting infected by germs.
▶ Wrong incubation setting.
▶ Health condition of mother bird.
▶ Improper egg turning.
When a chick hatches
out earlier than expected
or a deformed chick
hatches out
When a chick hatches
out later than
expected
▶ Setting temperature high. ▶Lower temp. setting of the
machine about 0.5℃ (1℉)
ex) 37.5℃(99.5℉) → 37.0℃(98.6℉)
▶Raise temp. setting of the machine
about 0.5℃ (1℉)
ex) 37.0℃(98.6℉) → 37.5℃(99.5℉)
▶ Setting temperature low.
▶Minimize the time to store egg properly.
▶Check Temperature difference in the
machine.
(sunlight, temp of incubation room, etc.)
▶Eggs stored for different lengths of time.
▶Diffferent incubation temperatures.
When hatching dates are
so different from each egg
(When all chicks don't
hatch out at the same time
but over a long period)
Troubles Expected Causes (Possibility) Countermeasures
DIGITAL INCUBATOR
6. Product Information (1) How to Service your MARU H&B
Replacing the Fuse,
General maintenance
18
Replace the Fuse
▶Replace ⓐ(Used Fuse) fuse
with ⓑ(Spare Fuse) fuse.
For AC 100V use :
250V 8.0A Ø5*20mm
For AC 230V use :
250V 8.0A Ø5*20mm
▶When the fuse is damaged,
remove the fuse at the inside
below of power connection
part, with screwdriver.
▶Fuse is located at the top of
power connection part on
back side of machine.
Back
All our Rcom digital products of Autoelex Co., Ltd. are made by precision systems under strict quality control. But
occasionally some defective products are found on the way of their distribution.If any problem occurs, then please
contact Autoelex service center or distributorsin your country. We will do our best to solve the problems, if any,
for you. This product is designed in modular mode, so for its repair, if any, a qualified person can replace the part
concerned with ease.
General maintenance

No signs of power
to the incubator.
▶Connect the cord again.
▶Check the main socket with any other
electric appliances.
▶Try to insert to another outlet.
▶Change the Fuse. [Refer to the page 18]
▶ Check electric cord is properly connected.
▶ Check if there is a power outage.
▶ Check whether the plug is damaged.
▶Check the fuse.
When temperature
is too high /
When temperature
is too low
Alarm sounds with
"HI" indication
(abnormal high temp.)
▶Check your setting temperature.
▶Initialize the machine. [Refer to the page 13]
▶
Please check the bottom of machine is wet or not.
▶Check air filter if there is dust on it.
▶Set the temperature as required.
▶Please remove moisture.
▶
Please put the water tank on the floor and use.
▶Clean up the air filter [Refer to the page 17]
▶Adjust room temperature 28℃(82.4℉)
▶
Install machine without the direct rays of sun.
▶Return machine to factory setting.
[Refer to page 13]
▶Check if room temperature is too high.
▶Check if machine is exposed to the direct
rays of sun.
▶In case of lowering temperature.
Alarm sounds with
"LO" indication
(abnormal low temp.)
▶Adjust room temperature 28℃(82.4℉)
▶Place thermometer inside of machine and
check if setting temperature is correct.
▶Please remove moisture.
▶
Please put the water tank on the floor and use.
▶Check if room temperature is too low.
(especially during night)
▶please check the bottom of machine is wet
or not.
Humidity will not
go high enough.
▶Supply water.
▶Check if silicon tube is blocked.
▶Set the humidity again as required.
▶
Clean the humidity unit. [Refer to page. 16~17]
▶ Move the H&B in warm place
▶Check your setting humidity.
▶Close the door again after checking.
▶Initialize the machine. [Refer to the page 13]
▶
Check if pumping is working. [Refer to the page 10]
▶Check if outside temperature is too low.
▶
Remove power and then open maintenance
cover to clean the FAN for air circulation.
[Refer to page 16~17]
▶Check if there is any hatching dust such as
feather or eggs-shell in the machine FAN.
▶A little noisy is not faulty.
- A little noisy occurs from
the inside of circulation fan.
The machine makes
some noise.
▶Check if you did not place the water
container on the machine.
▶Check that the machine placed on inclined
surface.
▶Check if it is Dew condensation.
▶When set as high humidity.
▶When moved without taking out the water
tank for the humidifier unit.
▶When humidity unit is not cleaned.
▶
Please put the water tank on the floor and use.
▶Place machine under a level surface.
▶Dew condensation is a natural phenomenon
and not a malfunction of the device.
▶Remove the remaining water in the humidity
unit using pipettes or syringe.
▶Clean the dust(scale) from the humidifier
unit after use.
Water leaks from
the machine.
Dew foams in
the incubator.
▶Check the machine is not placed too cold
circumstances.
▶When you turn OFF machine and then turn
ON.
▶In case of setting high humidity.
▶Adjust room temperature 28℃(82.4℉)
▶Dew condensation is a natural phenomenon
and not a malfunction of the device.
[Refer to the page 12]
Circumstance Items to be confirmed Solutions
Test the machine to be sure that the machine works without any problem before placing eggs in the machine.
Please ensure you remember how to use the machine and maybe re-read instructions.
6. Product Information (2) Troubleshooting(FAQ)
DIGITAL INCUBATOR 19
For more detailed self-diagnosis, see Rcom homepage
“SELF DIAGNOSIS” category.
Troubleshooting(FAQ)

1-1 Name : Rcom MARU DELUXE Hatcher & Brooder 100 /
Rcom MARU DELUXE Hatcher & Brooder 380
1-2 Model : MX-100HBD / MX-380HBD
DIGITAL INCUBATOR
6. Product Information (3) Specification
20
Specification
NAME Model No.
Model No.
300~350
MX-380HBD
MX-380HBD
Rcom MARU
DELUXE
H&B 380
Rcom MARU
DELUXE
H&B 100
Capacities
[Chick
egg size]
Egg basket +
Basket supporter
3 floors×1row
40~70MX-100HBD
temperature: 20~42℃(68~107.6℉)
humidity: 20~70%
temperature: 20~42℃(68~107.6℉)
humidity: 20~70%
Humidification
Device
Option
The number of
Trays
Dimensions
(W*H*L)
[mm]
7030440*838*823
Weight
[Kg]
Average
electric power
[W]
Maximum
electric power
[W]
Functional Ranger
MX-100HBD
Egg basket +
Basket supporter
1 floors×1row
60
440
44019419*368*732
NAME
Rcom MARU
DELUXE
H&B 380
Rcom MARU
DELUXE
H&B 100
This manual suits for next models
1
Table of contents
Other Rcom Accessories manuals

Rcom
Rcom MINI User manual

Rcom
Rcom 20 User manual

Rcom
Rcom KINGSURO MAX 20 User manual

Rcom
Rcom PRO 20 User manual

Rcom
Rcom INSECT MAX 90 User manual

Rcom
Rcom R-Com 20 User manual

Rcom
Rcom KINGSURO MAX 20 User manual

Rcom
Rcom PX-20RD User manual

Rcom
Rcom Juragon PX-20R User manual

Rcom
Rcom MARU DELUXE PRO Series User manual