Rcom REPTILE 90 Series User manual

WATER
DIGITAL REPTILE INCUBATOR
REPTILE MAX 90
USER'S MANUAL
Love of life begins with "Rcom"
Ver. 4
USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
Reptile Egg Incubator and Hatcher Rcom Max 90 User Manual

5. How to Clean
(1) Disassembling and Cleaning the Incubator 14
1. Introduction
(1) Rcom Reptile 90 Introduction 3 ~ 6
(2) Safety precautions
(4) Name & Function of Operation Parts
(3) Identification of Parts and Composition
7. Product Information
(1) Troubleshooting 16 ~ 18
(2) Specification
4. Function Settings
(1) Return to Factory Setting 10 ~ 13
(2) Temperature / Humidity Setting
(3) How to turn ON/OFF Humidification function
(5) Daily Temperature Range(D.T.G) setting method
(6) How to change Centigrade & Fahrenheit
(4) Abnormal high, Low temperature alarm setting method
2. Before use
(1) What is an Incubation Room?
8 ~ 10
(2) How to Assemble
3. Incubation
7
(1) Incubation Installation / Incubation Start
(2) Incubation Termination
6. Understanding
15
(1) Recommended temperature and humidity table by reptile during incubation
Introduction
Incubation
Product Information
Understanding
Function Settings
How to Clean
Before use
How to use Rcom Reptile MAX 90
Caution : Caution mark against a fault that can cause damage, trouble, or failure of incubation.
Tip : References or useful suggestions in using Rcom product
Mark Explanation
Warning of actions which may be dangerous or cause damage to the incubator.
Prohibited.
Do not disassemble.
Do not touch.
It is necessary to keep.
Remove the power cord from outlet.
Ground Connection for preventing electric shock.
The result of Hatching and Brooding can be changed by a large numbers of factors. Autoelex Co., Ltd.
& our distributors will not take any responsibility for ‘Loss of eggs or pet/animal lives’ under any
circumstances such as ‘Hatching/Brooding failures’, ‘User’s carelessness’, ‘Personal (un-certificated)
conversion / alteration’, ‘Arbitrary using out of the machine’s purpose’, ‘Electric power failure’, or
‘Malfunctioning’. Please be sure that the machine works without any problem before placing Eggs or
Pets(Animals). Also, we strongly recommend you to read the User’s Manual carefully to minimize of any
failure.
2DIGITAL INCUBATOR
Contents
USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
Reptile Egg Incubator and Hatcher Rcom Max 90 User Manual

[Main Function]
* Superior design with convenient operation
* Optimum air circulation technique with 3 high reliability BLDC fans
* Automatic Temp. & Humidity setting and control
* FND display with incubation information
* Body locking device
* Water supplement alarm function
* Antiblastic Humidification method by heating water, which discourages bacterial growth
* Double-glazed view window for minimizing the influence of outside temperature
* Enhanced reliability by applying Swiss's Sensirion's 3rd generation temperature & humidity sensor
* Powerful SMPS application for stable power supply
* The function of diurnal range (D.T.G)
[Safety Function]
* Alarm and display function of abnormal incubator temperature caused by sudden fluctuation of ambient temperature
* Incubation data memory function and power outage notification function in case of power failure
* Circulation fan cover for safety and electric safety cut-out switch on the upper main body for safety
* Heater supporter designed for heater tension control and its safety
* Safety cover applied for protecting humidification unit
* Humidification unit durability improved by water proof BLDC fan
* Alarm function when water needs replenishing
[Easy Function]
* No need of separate humidification unit as it included in main body
* Centigrade and Fahrenheit changing function
* Easy attachment and detachment of double-glazed viewing window
* Tray for incubation for exclusive use by reptile
* Bottom body designed for easy cleaning
* Micro chip with optimum incubation conditions according to the species of reptiles, for incubation beginners
Rcom Reptile 90
Features of Rcom Reptile 90
First of all, we would like to express our deep appreciation for all the customers who purchased Rcom Reptile
Incubator. Rcom Reptile Incubator was designed to be used easily and conveniently by the newest digital control
method for controlling optimal incubation environment automatically, however, in order to get the best incubation
result, at first, it is very important for users to have some incubation knowledge and right machine operation method.
Therefore, before suing incubator, be sure to read instruction manual. Rcom Reptile Incubator provides the best
incubation environment, however, it is necessary for users to observe and adjust each environment necessary for
incubation including egg kind, temperature and humidity management by incubation date, surrounding conditions
of incubator, and this product was made it possible to make the best setting for all the environments necessary for
incubation.
Daily temperature range function means as follows : It is a function artificially making the highest time zone of
temperature by sun at the natural condition, and it is a function that can raise the incubation success rate of reptile
by the optimal incubation environment by raising temperature at the fixed time zone.
DIGITAL INCUBATOR
(1) Rcom Reptile 90 Introduction
1. Introduction
3
USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
Reptile Egg Incubator and Hatcher Rcom Max 90 User Manual

Electrical hazards Be careful the details below when you use.
Do not pull the cord when
taking out the power cord, and
keep wet hands away from
connecting plug.
Do not use a damaged power
cord or loose outlet.
▶ Risk of electric shock or fire.
▶ Risk of electric shock or fire.
Do not insert multiple
connecting plugs in an outlet.
▶ Risk of fire or electrical
overload.
Never pull the plug out of the
outlet during the incubation
period.
▶Incubation will be interrupted.
Do not twist or crush electric
cord.
▶ Risk of electric shock or fire.
Setting Cautions Be careful the details below when you use.
Cleaning Cautions Be sure to disconnect the electric cord from the outlet
before cleaning.
Clean the incubator by a soft
cloth with a neutral detergent.
Do not spray cleanser directly
on the incubator surface.
Do not use chemicals like wax,
benzene, alcohol, thinner,
aromatic, or lubricant, etc.
Brush away dust on the plug
with a dry cloth.
For special cleaning of inner
part per year, contact to the
service center.
▶ If you don't clean the inside of
incubator for a long time, dust
can cause some trouble or a fire.
Do not install under the direct
sunlight.
Do not install in dusty or dirty
environment.
▶ Risk of fire or interference
with the incubation process.
▶ Risk of damage or fire within
the incubator.
Do not install in excessively
cold or hot conditions,
cigarette smoke, etc.
Do not install in moist or
humid environment.
▶ Risk of interference with
the incubation process.
▶ Risk of fire or electric shock.
Do not use any other
non-standard parts except
those provided.
▶ Risk of damage or hatching
failure.
Please ensure that no small
objects get into
the holes on the incubator.
▶ Risk of electric shock or fire.
Do not disassemble or modify
the incubator in any way.
▶ Risk if electric shock or fire.
If the incubator sounds
strange or emits smoke
contact your service center.
▶ Risk of electric shock or fire.
If the incubator requires repair
disconnect from the power
supply and please contact to
your service center.
Clean the incubator thoroughly
before storing.
Install away from heat
sources.
▶ Risk of damage to the
incubator case and
interference with the
incubation process.
Do not turn the incubator
upside down.
▶ Water will pour out of the
incubator, and view window
can be dropped or damaged.
Ensure that the incubator is
installed on a stable surface
away from edges.
▶ Risk of damage to incubator
and eggs and user from
accidental knocks or drops.
Do not cover the ventilating
opening.
▶ Inner temperature can rise,
interrupting incubation.
Children should be supervised
to ensure that they do not play
with the appliance.
DIGITAL INCUBATOR
4
1. Introduction (2) Safety Precautions
USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
Reptile Egg Incubator and Hatcher Rcom Max 90 User Manual

WATER
REAR
REAR
FRONT
Tray
Duplicated View Window
Identification of Parts
View Window
For a clear view of
the incubation process.
(Double Skin Viewing Window)
Reptile Vermi(vermiculite) and reptile
eggs Loading tray.
Egg Tray
Water hole
To facilitate water top-up
for the humidity control.
Main Body-1 Main Body-2
Power Connecting (the rear)
For connecting
power cord.
Serial No.
(EX:RCM0000000)
If you register your information with your
machine’s serial number on our web-site
(www.Rcom.co.kr), you can get 2 year
warranty service.
For circulating warm air
Vents for air circulation
For inlet of air
from outside
Air inlet vent
Digital Control Center
See description of
the function and operation.
Locking Button
Basic Components
Main Body-1
Water Cap
Main Body-2
Power Cord
User's Manual
View Window
Reptile Vermi(vermiculite)
170g x 2 sacks
DIGITAL INCUBATOR 5
1. Introduction (3) Identification of Parts
and Composition
USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
Reptile Egg Incubator and Hatcher Rcom Max 90 User Manual

Name & Function of Operation Parts
What’s ‘Temperature&Humidity Setting’?
This is that you set up temp.&humi. As you want to have inside of the machine.
(Blink with water shortage)
- Alarm for water supplement sounds in twice.
( First alarm with water shortage / Second alarm after 3 hours )
Blink with power failure
(to remove, press SET button)
(Lighting when working)
Setting Temp. Up
D.T.G mode
(Blink when working)
Temp. Display
Humi. working lamp
Power Failure Alarm Function
Humi. DisplayTemp. UP Button
Temp. DOWN Button
(Lighting when
working)
Heater Lamp
Daily temperature
range set
Setting Temp. Down
D.T.G Button
Water Supplement Lamp
Temp. Gap Lamp
Setting Humi. Up
Humi. UP Button
Setting value check
Setting Button
Humi. DOWN Button
Setting Humi. Down
[ Function Operation & Explanation ]
※If you want to change setting value, keep pressing "SET" button and change the value.
How to OperateFunction Explanation
Changing
Cels. & Fahr. Changing Cels. & Fahr.
Temp.
Setting Setting of needed temp.
Humidity
Setting
Daily Temp. Gap
(D.T.G) set
Setting of needed humidity.
How to OFF
Humidification
Function
Initialization
(Factory setting) Initialization
In case of incubation
at low humidity
D.T.G ON / D.T.G OFF
(one time a day for 3 hours
+ 1.5℃operation)
below 40%
DIGITAL INCUBATOR
6
1. Introduction (4) Name & Function of
Operation Parts
USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
Reptile Egg Incubator and Hatcher Rcom Max 90 User Manual

110V~120V
Serial NO.
6
▶Insert the power cord in the socket at the
back of the main body.
5
▶Lock the three locking buttons at the front
and rear of the incubator.
REAR
REAR
FRONT
2
1
3
4
View Window
Tray
Main Body-2
WATER
▶Register Serial NO. in the back of main body
(up). Free warranty period is extended to 2
years.(See 17 page)
How to Assemble
Incubation room? It means the place where the incubator is installed and operated, and as it has much effect on
incubation rate according to the environment of incubation room, it is good to install incubator at the place where
there is little noise and vibration in the vicinity and the temperature range isn’t severe in the temperature of 22~25℃
(71.6~77℉). In particular, as there are many cases that the temperature falls rapidly in the nighttime differently
from the daytime, it is necessary to check certainly, and during daytime, incubator must not be exposed directly to
the sunlight.
When installing reptile incubator, in case that the temperature of incubation room is higher than its set
temperature, the temperature control of incubator inside may not be done normally. The set temperature
of incubation room should be around 4℃(7.2℉) lower than incubator set temperature.
What is an Incubation Room?
Main Body-1
Water Cap
*
Fit the water cap.
*
Fit the water cap.
DIGITAL INCUBATOR 7
2. Before Use (1) What is an incubation Room?
(2) How to Assemble
USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
Reptile Egg Incubator and Hatcher Rcom Max 90 User Manual

Please be careful not to give any heavy power or shock
on the heater part for humidification in the upper side
of main body as it may be a cause of breakdown.
Some foreign substance is created on the heater part
after use, however, there isn’t any problem caused of it.
(See cleaning method)
▶It is for making water supply be smooth when beginning
incubation, and fill water for humidification in the water
tank located on [Fig-1] ⓐ, ⓑof downside main body.
▶See [Fig-7] for ⓒof [Fig.-1].
▶Heater part for humidification in the upper side of main
body[Fig. 2] should be submerged in the water of the
inside of water tank in case of assembling with the lower
part of main body. Please be sure to check and close
sight glass and plug in to operate for about 30~40 minutes.
▶In case of using without inserting water, it is necessary to
turn off its humidifying function.
(See humidifying function OFF mehtod)
Environment condition of incubation room for installing reptile
incubator.
(temperature : 22~25℃(71.6~77℉) / humidity : RH 30~50%)
In case of moving with water filled, as it may cause a
breakdown, fill water after installing it at the place
where you want to incubate.
[Fig-2]
REAR
REAR
FRONT
Heate
part for
humidification
▶It has an automatic humidifying function, however, as the
inside humidity of incubator depends on the water quantity
mixed with reptile vermi, please be sure to check the
incubation environment of reptile.
▶Put 2 bags of reptile vermis and 1200cc of water into tray
and mix. [Fig-3]
It is possible to purchase a vermiculite for reptile
incubation separately.
[Fig-1]
[Fig-3]
In case that the reptile vermi was completed dried, it
may be in very dry state by absorbing the surrounding
humidity of incubator inside and egg. It is good to start
after understanding the required environment for each
reptile kind and making previous test if incubation
environment is proper to minimize incubation failure.
[ 그림-2 ]
REAR
REAR
FRONT
1200cc
Preparation for Incubation
Before inserting eggs, please start incubation after
checking if all functions work without any problem by
operating incubator sufficiently.
DIGITAL INCUBATOR
8
3. Incubation (1) Preparation for Incubation /
How to Start Incubation
USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
Reptile Egg Incubator and Hatcher Rcom Max 90 User Manual

▶Set the environment of egg to be incubated to install the
prepared tray in the inside of incubator and close the lid
of sight glass tightly.
▶Check water for humidification every day and makeup
water as seen in [Fig.-5]. Then, it is necessary to stop it
when the Styrofoam ball in the inside comes up.
▶In case that the humidity of incubator inside isn’t controlled
into high humidity of RH 90~95% according to the
environment of incubation room, pour 75cc of water for
humidification on each edge of 4 tray sides for incubation
where without any egg meddle [Fig.-6] and pour 1000cc
of water on ⓒof [Fig-7] main body(bottom).
Even though the marking humidity of incubator is normal,
it is necessary to check the humidification state of
vermiculite at least once a week and check the state
of vermiculite once a month to makeup 400cc of water
as seen in [Fig.-6].
[Fig-5]
When reptile laid eggs, they should be moved to the
incubator as the first direction when laying eggs was.
It is convenient to making a marking on the egg in order
for them not to be changed.
In case that sight glass and water cap weren’t closed
completely, temperature and humidity aren’t normally
operated. Therefore, please be careful.
[Fig-4]
Marking
[Fig-7]
REAR
REAR
FRONT
1000cc
In case of humidifying inside humidity over RH 60%,
be sure to fill main body(bottom) of [Fig.-7] with 1000cc
of water, and in case of setting incubation humidity
into less than RH 60%, it isn’t necessary to pour water
on the bottom. In case of incubating at low humidity,
water may be created naturally on the bottom by dew
condensation. Therefore, it is necessary to check
sometimes to remove it.
It is good for reptile vermi not to be reused
after incubation. Incubation rate falls
notably because of Bacteria
contamination. [It is possible to
purchase at the place you purchased.]
▶Bury about 1/2 of egg to be incubated in
reptile vermin to fix egg. [Fig-4]
(During incubation, check the state of
eggs at least once a week and remove
unfertilized eggs, growth-stopped eggs
and moldy eggs.)
Please bury about 1/2.
[Fig-6]
100cc 100cc
100cc 100cc
3. Incubation (1) Preparation for Incubation /
How to Start Incubation
DIGITAL INCUBATOR 9
USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
Reptile Egg Incubator and Hatcher Rcom Max 90 User Manual

▶After all eggs are hatched, you should REMOVE the power cord for incubation termination.
(The incubator has no separate power switch.)
▶In case of neglecting it after turning off incubator during incubating at high humidity, the water leaving in the
inside evaporates and may create water drops on the FND window and control equipment. In order to prevent
this, separate the up and down of main body to dry it. (it may be possible to operate incubator for 1~2 hours
and dry its inside after removing the water for humidification of incubator inside.)
▶Connect power cord of incubator to start incubation into
the temperature and humidity set in the past.
[In case of initial shipment, temperature 26.1℃(78.98℉),
humidity RH 80%]
▶Set proper temperature and humidity of species to be
incubated to start incubation. It is necessary to pass some
period to be stabilized into set temperature and humidity.
There can be some odor the first time you use incubator,
which is normal.
Power Failure Notification : When firstly input power, or power
failure during incubation, second dot " . " of temp. display is
blink with alarm. Press SET to remove.
※The artificial intelligence system memorizes and classifies ambient conditions for keeping optimum temperature,
and temperature can move up slowly at the first stage.
110V~120V
+ =
"rSt" will show on the display
as below, and the incubator
initialize to factory setting.
▶It is for returning to the factory default setting.
▶It is for initializing the incubator setting or calibration to the factory settings when you handle the incubator
improperly so that the value has changed. Unplug the power supply and hold SET button and re-plug the power
supply as shown on picture. Then, rSt will show on the display, and the incubator will be iitialized to factory setting.
Re-plug the power supply
110V~120V
HOLD
Keep pressing SET button
How to Start Incubation
Incubation Termination
Return to Factory Setting
3. Incubation
4. Function Settings
(1) Preparation for Incubation / How to Start Incubation
(2) Incubation Termination
(1) Return to Factory Settion
DIGITAL INCUBATOR
10
USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
Reptile Egg Incubator and Hatcher Rcom Max 90 User Manual

▶Press button or button pressing
button to adjust into wanted temperature. Take hands off
from SET button to complete temperature setting and
display the temperature of present incubator inside.
In case of installing incubator at the place where direct
light lights or its surrounding temperature is too low,
it may be higher or lower than set temperature.
Press button to display set temperature and
humidity and take hands off to display present
temperature and humidity of incubator inside.
(
①
Keep pressing the button)
▶ Press button or button pressing
button to adjust into wanted humidity. Take hands off
from SET button to complete humidity setting and
display the present humidity of incubator inside.
The temperature or humidity of incubator is out of set
range according to the surrounding environment
(incubation room), there may be some difference.
(
①
Keep pressing the button)
Temperature and humidity is optimized when Rcom
products are released. We do no recommend customers
to recalibrate by their own. If you need to recalibrate,
please visit our website (www.Rcom.co.kr→Download→
Manual) or ask purchase place.Because of low price
thermometers and hygrometers are not accurate, e recommend you to use special calibrated thermo-
hydrometer. (Poultry only thermo-hydrometer: check Rcom website)
How to Turn ON/OFF Humidification Function
▶Continue to press button pressing button until “OFF” is displayed to turn off humidifying function.
▶Press button pressing button to set humidity into over RH 40%. Then, its humidifying function is on.
In case of using without putting water for humidification in or incubating at low humidity of less than RH 40%,
it is necessary to stop humidifying function. In case of not supplying water for humidification turning on
humidifying equipment, the humidifying unit part is damaged or the lifespan of part is shorten noticeably.
Be sure to turn OFF humidifying function equipment.
Temperature Setting
Humidity Setting
DIGITAL INCUBATOR
4. Function Settings (2) Temp. / Humi. Setting
(3) How to turn ON/OFF Humi. function
11
USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
Reptile Egg Incubator and Hatcher Rcom Max 90 User Manual

Abnormal high, Low temperature alarm setting method
When D.T,G function operates, TEMP. GAP lamp flickers.
D.T,G function is 1.5
℃
(2.7
℉
) higher than the existing
set temperature once a day for 3 hours.
ex) In case that reptile incubation temperature is 28.5
℃
(83.3
℉
), it is kept at 30
℃
(86
℉
) once a day for 3 hours.
▶Daily temperature range (D.T.G)?
It is a function artificially making the highest time zone of
temperature by sun at the natural condition, and it is a
function that can raise the incubation success rate of
reptile by the optimal incubation environment by raising
temperature at the fixed time zone.
※How to Set
* Max. abnormal temp. alarm limit [0.0 ~ 5.0
℃
(0 ~ 9
℉
) Default Setting : 0℃]
* Min. abnormal temp. alarm limit [0.0 ~ -5.0
℃
(0 ~ -9
℉
) Default Setting : 0
℃
]
5Sec. Set required
high range with
UP / DOWN button
Save setting and
pass to
low humi. set
Set required
low range with
UP / DOWN button
Save setting and
pass to current
temp. & humi.
indication
▶What is abnormal alarm function? It is an alarm function notifying it to user in case that the temperature of
incubator inside raised or decreased abnormally.
▶Press button pressing button to turn on
TEMP. GAP lamp and turn ON daily temperature range.
And turn off run lamp to turn OFF daily temperature range.
[Default Setting : ON]
Repeat
▶Press button and button at the same time
and press button at the state that CA was displayed
on temperature display window to change it.
(
①
Keep pressing the button)
(
①
Keep pressing the button)
TEMP +
TEMP -
Daily Temp. Range(D.T.G) setting method
How to change Cels. & Fahr.
4. Function Settings
DIGITAL INCUBATOR
(4) Abnormal high, Low temperature alarm setting method
(5) Daily Temperature Range(D.T.G) setting method
(6) How to change Centigrade & Fahrenheit
12
USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
Reptile Egg Incubator and Hatcher Rcom Max 90 User Manual

WATER
AUTOELEXAUTOELEX
AUTOELEXAUTOELEX
Unlock and remove the locking buttons for
three parts at the front and back of incubator
by pulling them forward.
▶When using humidification function, a lot of alien matter
sticks to the humidification heating element ⓐ. This may
not cause failure, but when terminating incubation please
clean the humidifying heater lightly with a soft brush.
▶If you place the main body(upper part) on the floor, please
don't let the humidification heating part touch with the floor.
Dry main body(bottom) and tray after washing
with water cleanly and dry main body(up) about
for one day at airy area in order to remove
remaining humidity in the inside completely.
In case of giving some shock on the heater part ⓐfor
humidification or drawing it with a sharp thing, the heater
for humidification is damaged.
In order to reduce foreign substance(scale) of the heater
part ⓐfor humidification, it is recommendable to use
distilled water as water for humidification. In case of
wanting to use other water, be sure to use it after
inquiring to the store purchased.
▶Pull out the electric cord from the connecting jack and
also take out the plug from the outlet.
In case of using distilled water as water for humidification,
it is possible to reduce foreign substance(scale) noticeably.
110V~120V
Back
110V~120V
In case of turning off the power immediately after using
incubator, it may be a cause of breakdown because of
the humidity remaining in the inside of main controller.
Then, it is necessary to turn it off after operating about
for 1 hour at the state of removing water for humidifi
cation of the incubator inside or reoperate it after
opening sight glass and naturally drying for 2~3 hours
in order to use machine for a long time.
Disassembling and Cleaning the Incubator
DIGITAL INCUBATOR
5. How to Clean
13
(1) Disassembling and
Cleaning the Incubator
USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
Reptile Egg Incubator and Hatcher Rcom Max 90 User Manual

WATER
REAR
REAR
FRONT
Start the vacuum cleaner to remove the dust as shown on
the right and thoroughly shake out the minute dust with a fine
brush.
If you finish cleaning the incubator, reassemble it in the
reverse order of disassembly. Wipe out outside the main
body with a wet cloth and dry it in a cool and well-ventilated
place before storage.
If the incubator goes through incubations several times,
dust, shell, etc. accumulate inside the main body,
which may cause a break down, so be sure to clean
the product before storage.
[Refer to How to assemble on Page 7.]
In case the incubator clean status is poor
which may cause fan noisy or stopping.
Don't clean the product with organic solvents such as
benzene, thinner, etc. which may cause deformation or
decoloration.
AUTOELEXAUTOELEX
AUTOELEXAUTOELEX
Cleaning
the fan
REAR
REAR
FRONT
5. How to Clean (1) Disassembling and
Cleaning the Incubator
DIGITAL INCUBATOR
14
USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
Reptile Egg Incubator and Hatcher Rcom Max 90 User Manual

North American King Snake
North American Milk Snake
60-65 days 28.3˚C / 83˚F 90%
60-65 days 28.3˚C / 83˚F 90%
North American Rat Snake 60-65 days 28.3˚C / 83˚F 90%
Corn Snake 55-60 days 29.4˚C / 85˚F 85%
King Snake 60-65 days 28.3˚C / 83˚F 90%
Amazon Tree Boa 40-50 days 31.1˚C / 88˚F 95%
Python 60-65 days 32.2˚C / 90˚F 90%
Iguana Green Iguana 73-80 days 29.4˚C / 85˚F 85%
Bearded Dragon Lizard 60-70 days 28.9˚C / 84˚F 85%
Uromastyx 55-65 days 33.9˚C / 93˚F 92% 1.5˚F/3hour
Chinese water dragon 60-75 days 29.4˚C / 85˚F 85%
Tegu 60-70 days 28.3˚C / 83˚F 90%
Lizard 50-60 days 30.6˚C / 87˚F 87%
Day Gecko 50-65 days 27.8˚C / 82˚F 75%
Gecko 50-55 days 29.4˚C / 85˚F 88-90% 1.5˚F/3hour
Alligator (Mississippiensis) 63-84 days 31.7˚C / 89˚F 95%
Crocodile (Crocodylus porosus) 89-95 days 30.6˚C / 87˚F 95%
Other Unknown Reptile 50-90 days 30.6˚C / 87˚F 85%
Alligator
Reptile Grouping SPECIES INCUBATION PERIOD TEMPERATURE HUMIDITY DAILY TEMPERATURE GAP
Chameleon Veiled Chameleon 145-180 days 26.1˚C / 79˚F 80%
Box Turtles 70-80 days 27.8˚C / 82˚F 85%
Sea Turtle 58-62 days 29.4˚C / 85˚F 95%
Painted Terrapin Turtle 72-80 days 29.4˚C / 85˚F 95%
Snapping Turtle 60-85 days 29.4˚C / 85˚F 95%
Turtle
Desert Tortoise 85-90 days 30.6˚C / 87˚F 80%
European Tortoise 56-84 days 30.6˚C / 87˚F 75%
Mediterranean Tortoise 56-70 days 30.6˚C / 87˚F 75%
Tortoise
Snake
Lizard
※The recommended environmental conditions as the reptiles may differ slightly.
Recommanded temp. and humi. table by reptile during incubation
DIGITAL INCUBATOR 15
(1) Recommanded temp. and humi.
table by reptile during incubation
6. Understanding
USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
Reptile Egg Incubator and Hatcher Rcom Max 90 User Manual

No signs of power
to the incubator.
▶Try to plug-in again.
▶Check other electric and electronic product
nearby.
▶Check after moving to other socket.
▶Check if power cord was connected well.
▶Check power failure.
▶Check if plug is defective.
When temperature
is too high /
When temperature
is too low
When humidity
is too high /
when humidity
is too low
▶Check set temperature.
▶Check if FAN for air circulation doesn’t rotate.
▶Try to make factory initialization. [See 11 page]
▶Adjust set temperature to wanted temperature.
▶Unplug from socket and separate main
body to clean FAN area for air circulation
with a brush or writing brush.
▶Refill water sufficiently.
<when low>
▶Check if foreign substance was inserted
and close it again.
<when high>
▶Adjust environment of incubation room.
[See 7 page]
▶Try to make factory initialization. [See 11 page]
<When low>
▶Check if sight window closed well.
<When high>
▶Check surrounding environment.
▶Check if tray inside or main body(bottom)
contains water.
▶Remove all the objects put on the incubator.
▶Move incubator to the safe place to install.
▶Unplug from socket and separate main
body to clean FAN area for air circulation
with a brush or writing brush.
▶Check if there is some other object on the
incubator.
▶Check if there is some vibration on the
floor or it was installed on the desk.
▶Check if some foreign substance was
attached to FAN area after incubation.
It is normal that the
machine emits some
sounds because it
uses air circulation
fan for working.
The machine makes
some noise.
▶As reptile incubator operates at high
humidity, there is some dew on the sight
window. It isn’t a breakdown but natural
phenomenon.
▶Please install within the condition of
incubation room.
Water leaks from
the machine.
* In case of keeping
at high humidity, there
may be some dew.
Troubles Expected Causes (Possibility) Countermeasures
Before inserting eggs, please start incubation after checking if all functions work without
any problem by operating incubator sufficiently.
For more detailed self-diagnosis, see Rcom homepage “SELF DIAGNOSIS” category.
Troubleshooting
All our Rcom digital products of Autoelex Co., Ltd. are made by precision systems under strict quality control. But
occasionally some defective products are found on the way of their distribution.If any problem occurs, then please
contact Autoelex service center or distributorsin your country. We will do our best to solve the problems, if any,
for you. This product is designed in modular mode, so for its repair, if any, a qualified person can replace the part
concerned with ease.
DIGITAL INCUBATOR
16
7.
Product Information (1) Troubleshooting
USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
Reptile Egg Incubator and Hatcher Rcom Max 90 User Manual

AC 100~120[V], 50/60[Hz] AC 220~240[V], 50/60[Hz]
Capacity
Temp. Control Range
Outside
Environment
Temp.
Humi. Control Range
20 ~ 42[℃] /
68 ~ 107.6[℉]
Optimal range : 22 ~ 25[℃] / 71.6 ~ 77[℉]
(Low) 20[℃] / 68[℉] (High) 26[℃] / 78.8[℉]
40 ~ 95[%] (It can be changed according to the conditions)
Temp. and Humi. accuracy
±0.5[℃], ±0.9[℉] / ±5[%]
Average 48[W] Max. 65[W]
Product Size
FUSE Standard 250[V] 2.0[A] (Ø5*20[mm])
(W)500×(L)410×(H)160[mm]
Product Weight 4.35[Kg]
Power Consumption
90[eggs] (Different from the species of egg)
Power
1-1 Name : Rcom Reptile MAX 90
1-2 Model : MX-R90
Specification
Register your product Serial No. on our website for free 2 years gurantee.
Refer to website for how to register. (Free 1 years gurantee in case not registerd.)
※Product Registration Procedures
If you are a new member of Rcom, you need to log in our website at www.Rcom.co.kr
1. Click “SIGN UP” on top of the right corner.
2. Fill out the information on the blanks.
If you already registered your information on the Rcom website, please log in to
www.Rcom.co.kr.
1. Click “Login” on top of the right corner.
2. Select “Customer” and click “Register Products”.
3. Fill out the information on the blanks.
You will need below information to register on our website.
1. Your name
2. Your (home/company) address & Email address, country
3. Your product(model) name & Serial number
4. Date of purchase & Name of purchased shop you bought from
DIGITAL INCUBATOR
7.
Product Information (2) Specification
17
USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
Reptile Egg Incubator and Hatcher Rcom Max 90 User Manual

Rcom PRO MINI Package (PX-03S)
BIRD BIRD
BIRD BIRD
Rcom MAX 20 (MX-20) Rcom PRO 50 (PX-50)
Rcom KINGSURO MAX 20 (MX-SURO)
Rcom REPTILE PRO 90 (PX-R90)Rcom REPTILE MAX 90 (MX-R90)
Rcom REPTILE MAX 60 (MX-R60) Rcom DIGILOG
(PX-V1)
Rcom DIGILOG2
(PX-V2)
Rcom REPTILE MAX 230 (MX-R230) Rcom REPTILE PRO 230 (PX-R230)
PUMPPOWER
POWERINLET
W
A
T
E
R
P
U
LL
OP
EN
Rcom Incubator Series
WATER
WATER
W
A
T
E
R
P
U
LL
OP
EN
W
A
T
E
R
P
U
LL
OP
EN
PUMPPOWER
POWERINLET
PUMPPOWER
POWERINLET
It is possible to check additional information at Rcom homepage (www.R-com.co.kr).
USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
Reptile Egg Incubator and Hatcher Rcom Max 90 User Manual

USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
Reptile Egg Incubator and Hatcher Rcom Max 90 User Manual

https://www.r-com-hatcher.com
SELLER
MANUFACTURER
● OFFICE : 218, Sangdong-ro, Sangdong-myeon,
Gimhae-si, Gyeongsangnam-do, 50805
South Korea :
https://www.R-com-hatcher.com
USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
Reptile Egg Incubator and Hatcher Rcom Max 90 User Manual
This manual suits for next models
1
Table of contents
Other Rcom Accessories manuals

Rcom
Rcom Reptile MAX 60 User manual

Rcom
Rcom USB 20 User manual

Rcom
Rcom INSECT MAX 140 User manual

Rcom
Rcom Juragon PX-20R User manual

Rcom
Rcom USB 50 User manual

Rcom
Rcom KINGSURO MAX 20 User manual

Rcom
Rcom PRO 20 User manual

Rcom
Rcom KingSuro ECO 20 User manual

Rcom
Rcom MARU DELUXE PRO Series User manual

Rcom
Rcom MARU DELUXE Hatcher & Brooder MX-100HBD User manual
Popular Accessories manuals by other brands

Brandson Equipment
Brandson Equipment 301826 user manual

Sentera Controls
Sentera Controls DTP-M Mounting and operating instructions

Axor
Axor Axor Montreux Towel Bar 42060XX0 parts list

Arlec
Arlec DC688 Installation & operating instruction

4CR
4CR FY-3C instruction manual

multicomp
multicomp 310-0900 instructions