Reed Instruments C-370 User manual

RTD
Thermometer
Instruction
Manual
C-370
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

2
Table of Contents
Introduction .................................................................................................... 3
Product Quality............................................................................................... 3
Safety ............................................................................................................. 3
Features.......................................................................................................... 3
Specications..............................................................................................4-5
Range Specifications ................................................................................. 4
Temperature Coefficient ............................................................................ 5
RTD Probe Accuracy Specifications.......................................................... 5
Instrument Description................................................................................... 6
Display Description ........................................................................................ 7
Operating Instructions...............................................................................8-13
Connecting the Pt100 RTD Probe (TP-R01).............................................. 8
Connector Configuration ........................................................................... 8
Powering the Meter ................................................................................... 8
Selecting Temperature Units...................................................................... 9
Taking Measurements ................................................................................ 9
Data Hold................................................................................................... 9
Backlight .................................................................................................... 9
Relative Function ..................................................................................... 10
MAX/MIN/AVG Function.......................................................................... 10
Auto Power Off ...................................................................................10-11
Pt Type Selection..................................................................................... 11
0°C Calibration......................................................................................... 12
Reset Calibration Value to Factory Settings .......................................12-13
Battery Replacement.................................................................................... 13
Applications.................................................................................................. 14
Accessories and Replacement Parts ........................................................... 14
Product Care ................................................................................................ 14
Product Warranty ......................................................................................... 14
Product Disposal and Recycling .................................................................. 15
Product Support........................................................................................... 15
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

3
Introduction
Thank you for purchasing your REED C-370 RTD Thermometer. Please
read the following instructions carefully before using your instrument. By
following the steps outlined in this manual your meter will provide years of
reliable service.
Product Quality
This product has been manufactured in an ISO9001 facility and has been
calibrated during the manufacturing process to meet the stated product
specications. If a certicate of calibration is required please contact the
nearest authorized REED distributor or authorized Service Center. Please
note an additional fee for this service will apply.
Safety
Never attempt to repair or modify your instrument. Dismantling your
product, other than for the purpose of replacing batteries, may cause
damage that will not be covered under the manufacturer's warranty.
Servicing should only be provided by an authorized service center.
Features
• Designedtomeetfoodservicestandards
• Quickresponding,highaccuracy
• Large,easy-to-readbacklitLCDdisplay
• Userselectable°C,°F
• Min/Max/Avgfunctions
• RelativemodeandDatahold
• IP67ratedwaterproofhousing
• Lowbatteryindicatorandautoshutoff
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

4
Specifications
MeasuringRange: -148to572°F(-100to300°C)
Resolution: 0.1°F/°C
Type: SingleInput,RTD
ResponseTime: 2x/second
Display: 31/2-digitLCD
BacklitDisplay: Yes
DataHold: Yes
Min: Yes
Max: Yes
Average: Yes
RelativeMode: Yes
AutoShut-off: Yes(after30minutes/off)
LowBatteryIndicator: Yes
PowerSupply: 3xAAABatteries
BatteryLife: Approx100hours(Alkaline)
ProductCertications: IP67,CE
OperatingTemperature: 32to104°F(0to40°C)
StorageTemperature: 14to140°F(-10to60°C)
OperatingHumidityRange: 10to90%
Dimensions: 5.9x2.6x1.2"(150x66x31mm)
Weight: 6.2oz(175g)
Range Specifications
Range Accuracy
-100~300°C ±(0.1%reading+0.4°C)
-148~572°F ±(0.1%reading+0.8°C)
Note: The basic accuracy specications does not include the error of
the RTD probe, refer to the RTD probe accuracy specications below for
additional details.
continued...
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

5
Temperature Coefficient
Forambienttemperaturesfrom0to18°Cand28to50°C,foreach
temperaturereadingbelow18°Corabove28°Caddthefollowing
toleranceintotheaccuracyspecication:
0.01%ofreading+0.03°C(0.01%ofreading+0.06°F)
RTD Probe Accuracy Specifications (TP-R01)
Sensor Type Platinum resistance thermometer sensor Pt 100
(4wires)
Accuracy IEC, class A
±0.15°C±0.002measurementtemperature
MeasurementRange -100to400°C
Temp. Sensor Dim. ApproximatelyØ3.2mm(Ø0.125")
Temp.SensorLength Approximately120mm(4.72")
CableLength Approximately1100mm(43.3")
Water-Resistant EN60529:1991,IP67
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

6
Instrument Description
C-370
9
1. PT00 Input Jack
2. LCDDisplay
3. Power Button
4. HOLDButton
5. MAX/MIN/AVGButton
6. Backlight Button
7. Relative Function Button
8. °C/°FButton
9. Battery Cover
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

7
Display Description
1
8
10
11
9
2
3
4
6
7
5
1. Battery Power Indicator
2. TemperatureReading
3. Platinum Type Indicator
4. MinimumValueIndicator
5. MIN/MAX/AVGTemperature
Reading
6. MaximumValueIndicator
7. AverageValueIndicator
8. TemperatureUnitofMeasure
Indicator
9. RelativeModeIndicator
10. Data Hold Indicator
11. Auto Power Off Indicator
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

8
Operating Instructions
Connecting the Pt100 RTD Probe (TP-R01)
Connect the Pt100 probe to the input jacks located at the top of the meter
as indicated below.
C-370
Connector Configuration
Source - Source +
NC
Sense + Sense -
Powering the Meter
To turn the meter on or off, press the POWER button.
continued...
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

9
Selecting Temperature Unit of Measure
1. When the meter is rst powered on the default scale setting is set to
Celsius(°C).
2. Pressthe°C/°F button to toggle between Celsius and Fahrenheit.
Note: The meter will automatically save the selected unit when turned off
as the new default.
Taking Measurements
Once the meter has been setup
and the Pt100 probe has been
connected, place the temperature
probe in the area being tested.
Givethemeterseveralseconds
to stabilize. Read the temperature
measurementontheLCD.If"----"
appears on the display, either the
reading is out of range or the Pt100
probe is not connected or it may
be defective.
Note: The temperature sensor is
located at the tip of the Pt100
probe. To accurately test internal
temperatures, make sure the probe is inserted at a distance of at least 15
times the diameter of the metal sheath as indicated in the diagram.
Data Hold
1. Press the HOLD button to freeze the current reading on the display.
2. Pressthebuttonagaintoresumenormaloperation.
Note: When Data Hold is active the MAX/MIN/AVG, °C/°F and REL
buttons are disabled.
Backlight
PresstheBACKLIGHTbuttontoturntheLCDBacklightonandoff.
Note: The backlight will automatically turn off after 10 seconds.
continued...
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

10
Relative Function
1. Press the REL button to store the current measurement.
2. Underthismode,themeterwilldisplaythedifferencebetweenany
new measurement and the stored measurement.
3. Press the RELbuttonagaintoexitRelativefunction.
MAX/MIN/AVG Function
When the buttonispressed,themeterwillentertheMAX/MIN/
AVGfunction.Underthisfunction,themaximumvalue,minimumvalue
and average values taken during the measurement process will appear on
the lower part of the display when selected.
Note: The average value is calculated using the last 8 readings in memory
and will update with every new reading.
1. The rst value to appear on the display in this function is the
Maximumvalueasindicatedbythe"MAX"symbolandisupdated
whenanewmaximumdatavaluehasbeentaken.
2. Pressthe buttonagainandtheMinimumvaluewillnow
appearonthedisplayasindicatedbythe"MIN"symbolandis
updated when a new minimum data value has been taken.
3. Press the button a third time and the Average value will now
appearonthedisplayasindicatedbythe"AVG"symbol.
4. Press the buttonafourthtimeandthe"MIN","MAX","AVG"
symbols will blink simultaneously while continuing to update the
readings in memory and can be viewed by returning to the appropriate
function. While in this function, the meter is displaying the current
measurement value only.
5. ToexittheMAX/MIN/AVGfunction,pressandholdthe button
for two seconds.
Note:WhenthemeterisinMAX/MIN/AVGfunction,the REL and °C/°F
buttons are disabled.
Auto Power Off
1. To preserve battery life, the meter is programmed to turn off after
30 minutes of inactivity.
continued...
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

11
2. Toturnthisfunctionoff,pressandholdtheHOLD button while
powering on the meter.
3. Release both buttons simultaneously.
4. There will be successive beeps emitted from the meter at start up
while the Auto Power Off indicator will not appear on the display,
conrming this feature is now disabled.
5. Ifthemeteristurnedoffthenbackon,the"AutoPowerOff"feature
will be enabled again.
Turnthepower"OFF"beforeattemptingthefollowingSETUPprocedures.
The setup mode will be cancelled if during the following procedures the
POWER button is pressed.
Pt Type Selection
While the meter is off, press and hold the POWER and BACKLIGHT
buttons for 2 seconds to enter the setup function. Press the HOLD
button to enter the Pt selection function. Press the MAX button to toggle
between Pt probe type as indicated by Pt100, Pt500 and Pt100. Press
the °C/°F button to conrm the selection.
continued...
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

12
0°C Calibration
Inserttemperatureprobeintoa0°Cstandardcalibratorunit
before calibration. Hold the probe until condition is stabilized
before starting calibration.
While the meter is off, press and hold the POWERandBACKLIGHT
buttonsfor2secondstoenterthesetupfunction.Pressthe REL button
to enter the calibration function. Enter the Pt selection rst. Press the
°C/°F button to conrm the Pt selection. Press the REL button to enter
the calibration function. Press the REL button to conrm the current
calibration value. Press the °C/°F button to conrm the selection and
resume normal operation.
Reset Calibration Value to Factory Settings
While the meter is off, press and hold the POWERandBACKLIGHT
buttonsfor2secondstoentersetupfunction.Pressthe REL button
to enter calibration mode. Enter Pt selection rst by pressing the MAX
button to toggle between Pt probe types. Press the °C/°F button to
conrmthePtselection.PresstheBACKLIGHTbuttontoenterthereset
function. Press the °C/°F button to reset the calibration value to factory
settings. Press the °C/°F button to conrm the selection and resume
normal operation.
continued...
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

13
Battery Replacement
When the low battery symbol,
,appears on the
display, the batteries need to
be replaced.
1. Remove all of the screws
located on the back of
the unit and remove the
cover as shown below.
2. Replacethethree(3)
"AAA"batteries.
3. Properly secure the cover
and tighten the screws.
The unit's back cover is tted with rubber rings. After
replacing the batteries, check that the rubber rings are
properly placed before reinstalling the back cover. Improper
placement of the rubber rings will compromise the unit's
water-resistant structure, and possibly result in damage to
the meter.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

14
Applications
• Medical
• Pharmaceutical
• IndustrialandCommercialTemperatureApplications
• R&DandEducationalEstablishments
• FoodService
Accessories and Replacement Parts
CA-05A Soft Carrying Case
TP-R01 Replacement Pt100 RTD Probe for REED C-370
Don't see your part listed here? For a complete list of all accessories and
replacement parts visit your product page on www.reedinstruments.com.
Product Care
Tokeepyourinstrumentingoodworkingorderwerecommendthefollowing:
• Storeyourproductinaclean,dryplace.
• Changethebatteryasneeded.
• Ifyourinstrumentisn'tbeingusedforaperiodofonemonthorlonger
please remove the battery.
• Cleanyourproductandaccessorieswithbiodegradablecleaner.Donot
spraythecleanerdirectlyontheinstrument.Useonexternalpartsonly.
Product Warranty
REED Instruments guarantees this instrument to be free of defects in
materialorworkmanshipforaperiodofone(1)yearfromdateofshipment.
During the warranty period, REED Instruments will repair or replace, at no
charge, products or parts of a product that proves to be defective because
of improper material or workmanship, under normal use and maintenance.
REED Instruments total liability is limited to repair or replacement of the
product. REED Instruments shall not be liable for damages to goods,
property, or persons due to improper use or through attempts to utilize the
instrumentunderconditionswhichexceedthedesignedcapabilities.In
order to begin the warranty service process, please contact us by phone at
1-877-849-2127orbyemailat[email protected]todiscussthe
claim and determine the appropriate steps to process the warranty.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

15
Product Disposal and Recycling
Please follow local laws and regulations when disposing or recycling your
instrument.Yourproductcontainselectroniccomponentsandmustbe
disposed of separately from standard waste products.
Product Support
If you have any questions on your product, please contact your authorized
REED distributor or REED Instruments Customer Service by phone at
1-877-849-2127orbyemailat[email protected].
Please visit www.REEDINSTRUMENTS.com for the most
up-to-date manuals, datasheets, product guides and software.
Product specifications subject to change without notice.
All rights reserved. Any unauthorized copying or reproduction of
this manual is strictly prohibited without prior written permission
from REED Instruments.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

TEST & MEASURE
WITH CONFIDENCE
CHECK OUT OUR LATEST PRODUCTS!
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com
Table of contents
Other Reed Instruments Thermometer manuals

Reed Instruments
Reed Instruments R2340 User manual

Reed Instruments
Reed Instruments R2320 User manual

Reed Instruments
Reed Instruments R2330 User manual

Reed Instruments
Reed Instruments R2330-NIST User manual

Reed Instruments
Reed Instruments R2450SD User manual

Reed Instruments
Reed Instruments R2000 User manual

Reed Instruments
Reed Instruments SMART Series User manual

Reed Instruments
Reed Instruments R2400 User manual

Reed Instruments
Reed Instruments Smart Series User manual

Reed Instruments
Reed Instruments R2020 User manual