REED 8778 User manual

reedinstruments
www com
Model 8778
Heat Stress
Meter
Instruction
Manual
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
1.888.610.7664info@REED-Direct.com REED-Direct.com

reedinstruments
www com
2
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
Table of Contents
Features......................................................................................... 3
Specications.............................................................................3-4
Instrument Description .................................................................. 4
Operating Instructions................................................................5-9
Select display mode.................................................................... 5
IN/OUT switch ............................................................................ 5
Select Unit .................................................................................. 5
Alarm Setting .............................................................................. 6
Auto Power Off (Sleep Function) ................................................. 6
Calibration ...............................................................................7-8
Troubleshooting .......................................................................8-9
RS232 Interface .......................................................................... 9
Battery Replacement..................................................................... 9
1.888.610.7664info@REED-Direct.com REED-Direct.com

reedinstruments
www com
3
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
Features
• WetBulbGlobeTemperature(WBGT)considerstheeffectsoftempera-
ture,humidityanddirectorradiantsunlight
• HeatStressIndexmeasureshowhotitfeelswhenhumidityiscombined
withtemperature,airmovementandradiantheat
• BlackGlobeTemperature(TG)monitorstheeffectsofdirectsolarradia-
tiononanexposedsurface
• In/OutfunctiondisplaystheWBGTvaluewithorwithoutdirectsun
exposure
• Viewindividualtemperaturesorindicesineither°For°C
• UseradjustableWBGTthresholdwithaudiblealarmifthresholdis
exceeded
• Autopoweroffwithoverride
• Built-inRS232andUSBinterface
• Tripodmountdesignforlong-termmonitoring
Specifications
AirTemp.Range: 0.0to50.0°C(32to122°F)
Accuracy: ±0.6°C(±1.1°F)
BlackGlobeTemp.Range:
0.0to80.0°C(32to176°F)
Accuracy: ±1°C:15to40°C,±1.5°C:restofrangeforindoor;
±1.5°C:15to40°C,±2°C:restofrangeforoutdoor
WBGTTemp.Range: 0.0to50.0°C(32to122°F)
Resolution: 0.1°C(0.1°F)
HumidityRange: 0to100%RH
Accuracy: ±3%RH:10to90%RH,±5%RH:restofrange
Resolution: 0.1%RH
OperatingConditions: 0to50°C,0-95%RH
StorageConditions: -20to65°C,0-95%RH continued ...
1.888.610.7664info@REED-Direct.com REED-Direct.com

reedinstruments
www com
4
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
PowerSupply: 2xAAAbatteries(included)
PowerConsumption: 1000hours(Alkaline),250hours(Generalpurpose)
Dimensions: 10x1.9x1.1”(254x49x30mm)
BlackBallDimensions:2.95x2.95”(75x75mm)
OptionalAccessories: Tripod(ModelBS-6)
33%HumidityCalibrationStandard(ModelHR33)
75%HumidityCalibrationStandard(ModelHR75)
USBCable&Software(ModelVZUSBAZM)
Instrument Description
LCD Display
WBGT WetBulbGlobeTemperature
TG BlackGlobeTemperature
TA AirTemperature
% RelativeHumidity
C/F Celsius/Fahrenheit
IN Indoor(noSun)
OUT Outdoor(fullSun)
Lowbatteryindicator
DP/RES1888 Unusediconsinthesemodels
1.888.610.7664info@REED-Direct.com REED-Direct.com

reedinstruments
www com
5
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
Operating Instructions
Pressthe buttontoturnthemeterONorOFF.
AllindicatorsontheLCDscreenwillashwhenyoupoweron.
Slidedownthesensor-protectingsheathbeforetakingameasurement.
Select display mode
ThemetermeasuresTA(AirTemp),TG(GlobeTemp),RH(Relative
Humidity),andcalculatesWBGT.Pressthe buttontoselectthemea-
suringmode.AniconwillappearonthetopoftheLCDscreentoindicate
thecurrentoperationmode(seeFig.A).
IN/OUT switch
TomeasureWBGTwithorwithoutdirectSunexposure,holddownthe
formorethan1secondtoswitch.EitherINorOUTwillthenbedisplayed
ontheLCDscreenindicatingweathertheunitissetforIndoor(noSun)or
Outdoor(fullSun)measuring.
Select Unit
Pressthe and buttonssimultaneouslyinmeasuringmodetoselect
°Cor°F.
Fig. A
1.888.610.7664info@REED-Direct.com REED-Direct.com

reedinstruments
www com
6
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
Alarm Setting
Thismeterfeaturesanaudiblealarmtogivewarningforpossibleheat
stressintheenvironment.WhenWBGTvaluereachesthealarmthreshold,
thevaluestartstoblinkandthereisacontinuousbeep.Thealarmstops
whenthemeasuredvaluefallsbelowthethresholdorthemeteristurned
off.Thealarmthresholdisadjustablefordifferentapplications.Whenthe
meterisOFF,holddownthe buttonfor2secondstoturnonthemeter
andenterthealarmsetting.Thecurrentsettingwillbedisplayedwitha
blinkingdigit.Pressthe buttontoincrementthevalueandthe but-
tonfor2secondstoreturntomeasuringmode.Thesettingrangeis20.0
–37.2°C(68-99.0°F).OUTwilldisplayontheLCDscreenifthesettingis
outofrange(seeFig.B).
Auto Power Off (Sleep Function)
ThemeterwillautomaticallypoweritselfOFFafter20minutesofinactivity.
Tooverridethisfunction,whenthemeterisoff,holddownthe and
buttonsfor2seconds.When“n”appearsintheLCDscreen,themeter
isnowinNon-Sleepmode.Whenthemeteristurnedoff,thedefaultwill
revertbacktothedefault(seeFig.C)
Fig. B
Fig. C
1.888.610.7664info@REED-Direct.com REED-Direct.com

reedinstruments
www com
7
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
Calibration
Thismetercanbecalibratedonthehumiditybyenduserswiththe
optional33%and75%saltsolution.Themambientconditionisrecom-
mendedtobeat23+/-2°Candastablehumidity.Userscanterminatethe
calibrationatanytimebypressingthe button.
33% Calibration
Besurethemeteristurnedoff.Unscrewtheblackglobewiththesensor
sheath(seeFig.1).
Plugthesensorprobeintotheoptional33%HumidityCalibration
Standard(ModelHR33)(seeFig.2).Holddownthe , andthe
buttonsfor2secondsuntilblinking“3X.X%”appearsontheLCDscreen.
Themeterisnowcalibratingandwillnishinapproximately60minutes.
Whenthevaluestopsblinking,themeterisdonecalibrating.
75% Calibration
Afterthe33%calibration,plugthesensorprobeintotheoptional75%
HumidityCalibrationStandard(ModelHR75)(seeFig.2).Pressthe
buttontobeginthecalibration,andablinking“7X.X%”willappearonthe
LCDscreen.Themeterisnowcalibratingandwillnishinapproximately
60minutes.Whenthevaluestopsblinking,themeterisdonecalibrating
andwillreturntomeasuringmode.
Fig. 1
Fig. 2
continued ...
1.888.610.7664info@REED-Direct.com REED-Direct.com

reedinstruments
www com
8
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
Reassembly
Reassembletheglobewithcautionbyttingthepin(seeFig.3)intothe
connection(seeFig.4).Ithelpstopositionbytargetingthescrewholeson
thesheathandthemeter(seeFig.5).Incorrectinstallationmaydamage
thesensor.
Note:TheRHvaluedifferencebetweenthemeterdisplayandcalibration
standardshouldbewithin+/-0.3%otherwisethecalibrationhasfailed.
Troubleshooting
Power on but no display
Checkthatthebatteriesareinproperlyandinthecorrectpolarity.Take
thebatteriesoutforoneminute,reinstallandretry.
Calibration failure
Checkthebatteryvoltageorreplacethemwithnewbatteries.Check
weatherthesenoriswellpluggedintothesaltbottleandnoaircomesin.
Checkambientcondition.
Fig. 3
Fig. 4
Fig. 5
1.888.610.7664info@REED-Direct.com REED-Direct.com

reedinstruments
www com
9
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
Error message on the display
E2: Thevalueisunderrange/Impropersensorinstallation
E3: Thevalueisoverrange
E4: Thevalueisinerrorbecauseoftheoriginaldata/
Improper sensor installation
E11: RHcalibratorerror,dothecalibrationagain
E32/E33:Circuiterror,contactREEDInstrumentsforrepair
or replacement
RS232 Interface
ThismetercandoPClinkforon-linelogginganddataanalysisviaRS232
interfaceandsoftware.Theprotocolisasfollows:
A. 9600bps,8databids,noparity.
B. Format(TransmittingASCIIcodeeverysecondwhilemeterison
Wxxx.xC(F):Txxx.xC(F):Txxx.xC(F):Hxx.x%LRCCRLF
Note:the1stvalueisWBGT,the2ndTA,the3rdTG,andthe4thisRH
Battery Replacement
The symbolwillappearonthebottomleftoftheLCDscreenwhenthe
batterypowerislow.Ifthebatteriesarenotreplacedtheaccuracyofthe
readingwillbeaffected.
1. Openthebatterycoveratthebackofthemeterandremovethe
batteries.
2. Insert2newAAAbatteriesandmakesurethebatteriesareinthe
correct polarity.
3. Reinstallthecover.
1.888.610.7664info@REED-Direct.com REED-Direct.com

reedinstruments
www com
10
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
Notes _________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
1.888.610.7664info@REED-Direct.com REED-Direct.com
Table of contents
Other REED Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

AccuEnergy
AccuEnergy AcuRev 1310 Series user manual

GESTRA
GESTRA LRG 16-40 Original Installation Instructions

Tobi
Tobi PI Wi-Z Quick installation guide

Renishaw
Renishaw SP600 Installation and user guide

Textron
Textron HD Electric Proof Tester PT-5000 Operating instructions manual

Deepace
Deepace KC901V manual