3
II. I TRODUCTIO
This booklet contains the installation and operating instructions for your combination gas
heating/electric cooling unit. There are some precautions that should be taken to derive
maximum satisfaction from it. mproper installation can result in unsatisfactory operation
or dangerous conditions.
Read this booklet and any instructions packaged with separate equipment required to
make up the system prior to installation. Give this booklet to the owner and explain its
provisions. The owner should retain this booklet for future reference.
III. CHECKI G PRODUCT RECEIVED
Upon receiving the unit, inspect it for any damage from shipment. Claims for damage,
either shipping or concealed, should be filed immediately with the shipping company.
IMPORTANT: Check the unit model number, heating size, electrical characteristics, and
accessories to determine if they are correct.
IV. SPECIFICATIO S
A. GE ERAL
The Combination Gas Heating/Electric Cooling Rooftop is available in 100,000 and
135,000 BTU/Hr. heating inputs and cooling capacity of 6 nominal tons of cooling. Units
are convertible from bottom supply and return to side supply and return by relocation of
supply and return air access panels. See cover installation detail.
The units are weatherized for mounting outside of the building.
The information on the rating plate is in compliance with the FTC and DOE rating for sin-
gle phase units. The following information is for three phase units which are not covered
under the DOE certification program.
1. The energy consumption of the ignition system used with this unit is 9 watts.
2. The efficiency rating of this unit is a product thermal efficiency rating determined
under continuous operating conditions independent of any installed system.
B. MAJOR COMPO E TS
The unit includes a hermetically-sealed refrigerating system (consisting of a scroll com-
pressor, condenser coil, evaporator coil with thermostatic expansion valve), a circulation
air blower, a condenser fan, a heat exchanger assembly, gas burner and control assem-
bly, combustion air motor and fan, and all necessary internal electrical wiring. The cool-
ing system of these units is factory-evacuated, charged with R-410A refrigerant and per-
formance tested. Refrigerant amount and type are indicated on rating plate.
C. R-410A REFRIGERA T
All units are factory charged with R-410A refrigerant.
1. Specification of R-410A:
Application: R-410A is not a drop-in replacement for R-22; equipment designs must
accommodate its higher pressures. t cannot be retrofitted into R-22 units.
Pressure: The pressure of R-410A is approximately 60% (1.6 times) greater than R-
22. Recovery and recycle equipment, pumps, hoses and the like need to have design
pressure ratings appropriate for R-410A. Manifold sets need to range up to 800 psig
high-side and 250 psig low-side with a 550 psig low-side retard. Hoses need to have a
service pressure rating of 800 psig. Recovery cylinders need to have a 400 psig service
pressure rating. DOT 4BA400 or DOT BW400.
Combustibility: At pressures above 1 atmosphere, mixture of R-410A and air can
become combustible. R-410A and air should never be mixed in tanks or supply
!WAR I G
T E MANUFACTURER’S WARRAN-
TY DOES NOT COVER ANY DAM-
AGE OR DEFECT TO T E AIR CON-
DITIONER CAUSED BY T E
ATTAC MENT OR USE OF ANY
COMPONENTS, ACCESSORIES OR
DEVICES (OT ER T AN T OSE
AUT ORIZED BY T E MANUFAC-
TURER) INTO, ONTO OR IN CON-
JUNCTION WIT T E AIR CONDI-
TIONER. YOU S OULD BE AWARE
T AT T E USE OF UNAUT O-
RIZED COMPONENTS, ACCES-
SORIES OR DEVICES MAY
ADVERSELY AFFECT T E OPERA-
TION OF T E AIR CONDITIONER
AND MAY ALSO ENDANGER LIFE
AND PROPERTY. T E MANUFAC-
TURER DISCLAIMS ANY RESPON-
SIBILITY FOR SUC LOSS OR
INJURY RESULTING FROM T E
USE OF SUC UNAUT ORIZED
COMPONENTS, ACCESSORIES OR
DEVICES.
!WAR I G
UNITS ARE NOT DESIGN CERTIFIED TO BE INSTALLED INSIDE T E STRUC-
TURE. DOING SO CAN CAUSE INADEQUATE UNIT PERFORMANCE AS WELL
AS PROPERTY DAMAGE AND CARBON MONOXIDE POISONING RESULTING
IN PERSONAL INJURY OR DEAT .
Recognize this symbol as an indi-
cation of mportant Safety
nformation!
!
!WAR I G
INSTALL T IS UNIT ONLY IN A
LOCATION AND POSITION AS
SPECIFIED IN T E LOCATION
REQUIREMENTS AND CONSIDERA-
TIONS SECTION OF T ESE
INSTRUCTIONS. PROVIDE ADE-
QUATE COMBUSTION AND VENTI-
LATION AIR TO T E UNIT SPACE
AS SPECIFIED IN T E VENTING
SECTION OF T ESE INSTRUC-
TIONS.
!WAR I G
PROVIDE ADEQUATE COMBUS-
TION AND VENTILATION AIR TO
T E UNIT SPACE AS SPECIFIED IN
T E COMBUSTION AND VENTILA-
TION AIR SECTION OF T ESE
INSTRUCTIONS.
!WARNING
EFFICIE CY TESTI G OTICE
FOR PURPOSES OF VERIFYI G OR TESTI G
EFFICIE CY RATI GS, THE TEST PROCEDURE
I TITLE 10 PART 431 APPE DIX A TO
SUBPART F (U IFORM TEST METHOD FOR
MEASURI G THE E ERGY CO SUMPTIO OF
SMALL LARGE A D VERY LARGE
COMMERCIAL PACKAGE AIR CO DITIO I G
A D HEATI G EQUIPME T), TITLE 10 PART
431.76 SUBPART D (U IFORM TEST METHOD
FOR MEASURI G E ERGY CO SUMPTIO OF
COMMERCIAL WARM AIR FUR ACES), A D
THE CLARIFYI G PROVISIO S PROVIDED I
THE AHRI OPERATIO S MA UALS FOR
U ITARY LARGE EQUIPME T 340/360, 365
A D COMMERCIAL FUR ACES THAT WERE
APPLICABLE AT THE DATE OF MA UFACTURE
SHOULD BE USED FOR TEST SET UP A D PER-
FORMA CE.