GM700S 1) Press and release the Main button " " to turn on the meter.
2) Press and hold the Main button " " for 7 seconds to enter the Setting Mode. The year will flash.
(Note: The meter will turn off while you are holding down the button. Continue holding down the Main
button to reach the Setting Mode. You will then be asked to set the year.)
3) Press the Left button " " or Right button " " to change the year.
4) Press the Main button " " to confirm the year and move onto the month setting.
2
Main Button ( )
Press to turn on/off
meter or go into setting
mode.
Test strips vial Control Solution
Lancing Device
Lancet
Installating the Batteries
1
1) Turn the meter over. Press and push battery cover to open.
2) Install the battery. Be sure to put battery in correct direction.
3) Slide the battery cover back until it snaps into place.
Setting Up Your Meter - Set the Date, Time, Volume and Measurement Unit
Front View of Meter Back View of Meter
Test strips
Sample Entry
View Window
Protective cover
PlungerHubLancet carrier
Release button
Safe switch
Depth adjustable cap
Blood Glucose Meter GM700S Getting Started Guide ( For self-testing )
Display Window:
Show your test result,
messages and relative
information.
Test Strip Port:
Insert test strip here until
you hear a click.
Up Button ( )
For operating the
meter.
Down Button ( )
For operating the
meter.
NOTE
- In order to ensure proper operation, do not use this meter close to strong sources
electromagnetic radiation.
- Keep the meter free of dust and liquids, including water.
Preparing the Lancing Device
1 2 3
1) Hold the adjustable depth cap in one hand while holding the base with the other hand. Pull the
cap in the down direction. When a gap appears between the cap and base, pull the two parts in
opposite directions.
2) Remove the adjustable depth cap.
3) Insert a new disposable lancet firmly into the lancet carrier.
5) Repeat step 3 and 4 to change the date, time format, hour, minute, volume and measurement unit.
After pressing the main button to confirm the volume setting, your set-up is complete.
3
GM700S
2.0µ 3.00.75µ 1.0µ 1.5µL L L L µL
Performing a Test
4) Twist off and set aside the protective cover of the disposable lancet.
5) Replace the depth adjustable cap.
6) Choose a depth of penetration by rotating the top portion of the depth adjustable cap until the setting
depth matches the window. Settings are based on skin type
” “ for soft or thin skin;
” “ for average skin;
” “ for thick or calloused skin.
7) Hold the hub in one hand and pull on the plunger in the other hand. The device will be cocked.
Release the plunger, it will automatically move back to its original position near the hub.
4
BIONIME CORPORATION
No. 100, Sec. 2, Daqing St., South Dist.,
Taichung City 40242, Taiwan
Tel: +886 4 2369 2388 Fax: +886 4 2261 7586
Email: [email protected] Website: www.bionime.com
4 6 7
8
12
9 10 11
Bionime GmbH
Tramstrasse 16
9442 Berneck
Switzerland
E-mail: [email protected]
5
57
Sample Size Example
4
6
1 2 3
101-3GM780-020
EN
Rev. Date: January/2014
1) Wash and dry your hands. Take one test strip from the vial. Close the vial cap immediately.
2) Insert the test strip into the test strip port on the meter with the view window facing up. Push the test
strip in until you hear a click. The meter will automatically detect the code number.
3) When you see the flashing blood drop icon on the display window, hold the lancing device to your
fingertip and press the release button.
4) A blood drop size between 0.75 and 3.0 is required for testing. See Sample Size Example Chart
for drop sizes. Blood drop sizes greater than 3.0µL may contaminate the meter. A minimum of a
0.75µL drop is required for accurate results.
µL µL
5) Touch and hold the drop to the edge of sample port until you hear a "beep" and the view window is
filled with blood. If the view window is not completely filled with blood, the test will not start. Discard
the test strip and repeat the test with a new test strip.
6) The countdown will begin on the display window. After 5 seconds, your test result will appear. For
more information about your test results, please see your User’s Manual.
7) Remove the test strip from the meter. Please follow your local regulations to properly discard the
used test strip.
8) Pull off the adjustable depth cap. Without touching the used disposable lancet, stick the lancet tip
into the protective cover.
9) Hold the release button in one hand and pull the plunger with the other hand. This will safely eject
the used disposable lancet.
10) Discard the used disposable lancet into an appropriate puncture-proof or biohazard container.
11) Replace the adjustable depth cap after finishing the test.
Alternative site testing: palm or forearm blood sampling
1.
2. Massage the puncture area of your palm or forearm for a few seconds.
3. clear
cap
4. Press the release button.
5. Continue holding the lancing device against your palm or forearm. Gradually increase pressure for
a few seconds until the blood sample size is sufficient.
6. Follow step 9 to discard the used disposable lancet.
NOTE: DO NOT test on the palm or forearm if you are testing for hypoglycemia (low blood glucose).
Choose the clear cap and follow step 1 and step 2 “Performing a Test”.
Immediately after massaging the puncture area, press and hold the lancing device with the
against your palm or forearm.
NOTE
- The Rightest™ Lancing Device is intended for single person use only.
For more information on how to use your meter and understand your test results, please see the
User Manual.
4
Pressing for
a few seconds
5
Releasing
button
GM700S
GM700S
GM700S
GM700S

Other Rightest Blood Glucose Meter manuals

Rightest HM312 User manual

Rightest

Rightest HM312 User manual

Rightest GM700 Pro 2 User manual

Rightest

Rightest GM700 Pro 2 User manual

Rightest GS100 User manual

Rightest

Rightest GS100 User manual

Rightest GT333 User manual

Rightest

Rightest GT333 User manual

Rightest Wiz User manual

Rightest

Rightest Wiz User manual

Rightest GT333 User manual

Rightest

Rightest GT333 User manual

Rightest BIONIME GM300 User manual

Rightest

Rightest BIONIME GM300 User manual

Rightest GS100 User manual

Rightest

Rightest GS100 User manual

Rightest GM250S User manual

Rightest

Rightest GM250S User manual

Rightest Max User manual

Rightest

Rightest Max User manual

Rightest GT200 User manual

Rightest

Rightest GT200 User manual

Rightest GT100 User manual

Rightest

Rightest GT100 User manual

Rightest GM700SB User manual

Rightest

Rightest GM700SB User manual

Rightest GS280 User manual

Rightest

Rightest GS280 User manual

Rightest Max Tel User manual

Rightest

Rightest Max Tel User manual

Popular Blood Glucose Meter manuals by other brands

Dexcom G5 Mobile user manual

Dexcom

Dexcom G5 Mobile user manual

MediSense Optium Xceed Quick reference guide

MediSense

MediSense Optium Xceed Quick reference guide

Roche Accu-Chek Mobile instructions

Roche

Roche Accu-Chek Mobile instructions

GlucoCheck EVOLVE. owner's manual

GlucoCheck

GlucoCheck EVOLVE. owner's manual

embrace No Code manual

embrace

embrace No Code manual

bloom AMH test Instructions for use

bloom

bloom AMH test Instructions for use

A.MENARINI GLUCOFIX TECH user manual

A.MENARINI

A.MENARINI GLUCOFIX TECH user manual

Trividia True Metrix owner's booklet

Trividia

Trividia True Metrix owner's booklet

Lifescan In Duo manual 

Lifescan

Lifescan In Duo manual 

CONTOUR NEXT GEN user guide

CONTOUR NEXT

CONTOUR NEXT GEN user guide

Microlife BP W3 Comfort instructions

Microlife

Microlife BP W3 Comfort instructions

AgaMatrix iBGStar owner's guide

AgaMatrix

AgaMatrix iBGStar owner's guide

Metene TD-4116 user manual

Metene

Metene TD-4116 user manual

iHealth BG1 quick start guide

iHealth

iHealth BG1 quick start guide

Bayer HealthCare Contour TS user guide

Bayer HealthCare

Bayer HealthCare Contour TS user guide

Lifescan SureStep blood glucose monitoring system owner's booklet

Lifescan

Lifescan SureStep blood glucose monitoring system owner's booklet

Accu-Chek Aviva Advanced owner's booklet

Accu-Chek

Accu-Chek Aviva Advanced owner's booklet

Bayer HealthCare Ascensia Contour Blood Glucose Meter user guide

Bayer HealthCare

Bayer HealthCare Ascensia Contour Blood Glucose Meter user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.