Strip length for the conductors used with the WAGO connector is 9 … 10 mm
The brake can only be used with 50Hz or 60Hz, no adjustment is necessary.
The cable shall be selected according to the Canadian Electrical Code, part 1 or National
Electrical Code.
Supply voltage: Operating voltage is marked on the nameplate, single phase.
Line protection: 10 A type B or 6 A type C; protection has to be ensured by the user!
cable Supply cable: 1-1,5 mm² flexible, only Cu conducters shall be used, not longer than 50m, L and
N can be swapped; outer diameter of the supply cable: 5-10mm (cable gland) and 8-10mm (plug),
do not lay the supply cable together with supply cable from electrical motors in one cable duct.
Use surge protectors! Cable length between electronic and brake not longer than 5m.
PE, grounding conducter: 1-1,5 mm2, connected via cable lugs to the electronic box and splicing
connector (see picture above).
Switching function: directly on the operating voltage, between electronics and supply voltage, dou-
ble pole switching! Max. Inrush current 6 A rms (15 A peak) for 0,2s, than smaller 0,6 A (rms).
After the electrical connection you have to check the protective earth conductor function (accord-
ing DIN VDE 0113 or EN 60204).
Brake size 024, 028 and 038
Fig. 8.4
The brake can only be used with 50Hz or 60Hz, no adjustment is necessary.
The cable shall be selected according to the Canadian Electrical Code, part 1 or National
Electrical Code.
Supply voltage: Operating voltage is marked on the nameplate, single phase.
Line protection: 10 A type B or 6 A type C; protection has to be ensured by the user!
cable Supply cable: 1-1,5 mm² flexible, only Cu conducters shall be used, not longer than 50m, L and
N can be swapped; outer diameter of the supply cable: 5-10mm (cable gland) and 8-10mm (plug),
do not lay the supply cable together with supply cable from electrical motors in one cable duct.
Use surge protectors!
PE, grounding conducter: 1-1,5 mm2, connected via cable lugs to the electronic box and splicing
connector (see picture above).
Switching function: directly on the operating voltage, between electronics and supply voltage, dou-
ble pole switching! Max. Inrush current 15 A rms (24 A peak) for 0,2s, than smaller 1 A (rms).
After the electrical connection you have to check the protective earth conductor function (accord-
ing DIN VDE 0113 or EN 60204).
8.5 Braking force adjustment
The entire surface of both brake pads must be in contact with the brake disc in order to achieve
the optimum braking effect. The brake pads must also be heated briefly to approx. 200°C. There-
fore, multiple brief braking operations under low spring force and rotating brake disc are required
to heat the brake pads.