Slimfire 25 Zero Clearance Box 10/06/2003
2
RINNAI SLIMFIRE Zero Clearance Kit
Only the FLFKIT02 and FLFKIT03 can be used in
conjunction with the Zero Clearance Box
Check roof space for any flue obstructions. If the
required clearance from flue to combustible material
cannot be obtained (25mm), The flue can be offset
with the use of two 45°Bends (FLFBEND).
Install the double-lined flue with 150mm black outer
section to penetrate 30mm through the hole the Zero
Clearance Box, and the inner section to penetrate
50mm. Note: Ensure the flue is fully supported
independently of the appliance AS5601/AS601 Clause
5.13.4.2 and 5.13.4.3
When the heater is installed the slip collar is used to
connect the heater to the flue.
This installation is designed to ensure that any residual
heat in the Zero Clearance Box is ducted away up in
the cavity between the inner and outer flue pipes.
Extend the flue outer to terminate in the roof space and
the inner flue pipe to atmosphere in accordance with
AS5601/AS601 Clause 5.13.6.
For single story installations use flue kit FLFKIT02
(Fig.5).
For two story installations use flue kit FLFKIT03
This appliance shall be installed in accordance with:
• Manufacturer’s Installation Instructions
• Local Gas Fitting Regulations
• Municipal Building Codes
• A.G.A. Installation code AG601/AS5601/ Gas Installations
• Any other local relevant Statutory Regulation
Installation & Service must be performed by an
authorised person.
680
750
670
40 365
266
50
For further information please call the Rinnai Australia Technical Helpline
1300 366 388
SLIMFIRE
HEATER
SLIP
SOCKET
100 mm
TWIN SKIN
LENGTH
1000 mm x 2
TWIN SKIN
CLEARANCE FROM
COMBUSTABLE 10 mm
SINGLE SKIN
CLEARANCE
FROM
COMBUSTIBLE
25 mm
CHIMNEY
COWL
Minimum
Clearance
500 mm
Fig.5