SR-496 Surface Resistance Meter
Instruction Manual
The surface resistance can be measured by attaching two parallel electrodes of the instrument to the surface
of the measured object. Thus you can determine whether the measured object is a conductor, anti-static
material, or an insulator. The instrument is particularly suitable for a variety of anti-static areas.
A. Specifications of SR-496
Resistance Measurement Range
0.1 x 103 ~ 1.5 x 1012 Ω
Resistance Measurement Accuracy
<±10%
Response Time
Approx. 1 sec.
Temperature Measurement Range
0℃~ +50℃(+32℉~ +122℉)
Temperature Measurement Accuracy
±1℃(±1.8℉)
Power Supply
One 9V battery
Dimension
64 x 35 x 126mm (2.5” x 1.2” x 5.0”)
Weight
Approx. 156g (battery included)
B. Material Resistance Range
Conductor
<106
Anti-Static Material
106 ~ 1011
Insulator
≧1012
※The signal is weak when measure surface resistance of 1011 Ω or more, in order to ensure stable and
reliable measurement, it is necessary to make environment where electromagnetic interference is small.
During the measurement process, make sure that no person walks within 3 meters.
C. Function
▶Surface resistance test
▶Three ways to display the surface resistance or material properties simultaneously
▶Environment temperature measurement
▶Temperature unit conversion
▶Data hold
▶LCD backlight
▶Auto turn off
D. LCD Display (Please see the right photo.)
①Insulation material indicator
②Anti-static material indicator
③Conductor indicator
④Resistance value
⑤Temperature value
⑥Resistance measurement indicator
⑦Data hold indicator
⑧Battery indicator
- 2 -
E. Instrument Description (Please see the right photo.)
(A) LCD display
(B) Conversion of resistance mode and temperature unit
(C) Resistance measurement and data hold
(D) On/off button and backlight button
(E) Ground wire jack
(F) Measurement electrode
(G) Battery cover
F. Operation Instruction
1. Power On
Press " " button to turn on the instrument. About 1 sec., the instrument will be ready to measure.
2. Resistance Display Mode
Press " " to switch the resistance display mode: Order of magnitude mode/conventional mode.
3. Backlight
After power on, press " " button to turn on/off the backlight.
4. Temperature Unit Conversion
Long press " " button to switch the temperature units: Celsius (°C) and Fahrenheit (°F).
5. Resistance Measurement
After turning on the instrument, put the instrument on the surface of measured object, press and hold
"" key to start measurement, at the same time, the “TEST” indicator will be displayed.
During measurement, resistance display area displays "----" (on normal mode) or "--x-" (on order of
magnitude mode), indicating that the instrument is measuring.
After the resistance value is measured, the resistance value will be displayed in resistance display area.
When the resistance value is higher than measurement range, resistance display area will show “HI”.
When the resistance value is lower than the measurement range, the “Lo” will be displayed.
After releasing the measurement button, the measurement will finish and the data will be held,
"HOLD" indicator shows up simultaneously.
6. Shutdown
After power on, long press " " button to shut down.
If there is no operation within 30 seconds, the instrument will shut down automatically.
※Specific Declarations :
Our company shall hold no any responsibility resulting from using this product as a direct or
an indirect evidence. We reserve the right to modify product and specification without notice.
SR496-1607-EN02

Other Rixen Measuring Instrument manuals

Rixen LXP-420 User manual

Rixen

Rixen LXP-420 User manual

Rixen A80 User manual

Rixen

Rixen A80 User manual

Rixen TH-3800 User manual

Rixen

Rixen TH-3800 User manual

Rixen M-700 User manual

Rixen

Rixen M-700 User manual

Rixen M70-D User manual

Rixen

Rixen M70-D User manual

Rixen VF-5204 User manual

Rixen

Rixen VF-5204 User manual

Rixen VF-5200 series User manual

Rixen

Rixen VF-5200 series User manual

Rixen M-700S User manual

Rixen

Rixen M-700S User manual

Popular Measuring Instrument manuals by other brands

YOKOGAWA ADMAG AM100D user manual

YOKOGAWA

YOKOGAWA ADMAG AM100D user manual

Triplett PQC300 user manual

Triplett

Triplett PQC300 user manual

Sartorius PT-10 Service manual

Sartorius

Sartorius PT-10 Service manual

SIMARINE SC303 user manual

SIMARINE

SIMARINE SC303 user manual

Anderson IZMSG instruction manual

Anderson

Anderson IZMSG instruction manual

UEi CLM100 instruction manual

UEi

UEi CLM100 instruction manual

Nokia Nokia Sleep Quick installation guide

Nokia

Nokia Nokia Sleep Quick installation guide

Tektronix 6 series Installation and safety manual

Tektronix

Tektronix 6 series Installation and safety manual

Oval FLOWPET-EG LS5277-4 0B Series instructions

Oval

Oval FLOWPET-EG LS5277-4 0B Series instructions

Besantek BST-LT01 instruction manual

Besantek

Besantek BST-LT01 instruction manual

Rion VA-12 instruction manual

Rion

Rion VA-12 instruction manual

Svantek SV 277 PRO user manual

Svantek

Svantek SV 277 PRO user manual

Alaron MTP-8010 instruction manual

Alaron

Alaron MTP-8010 instruction manual

Spectra Precision HV302 user guide

Spectra Precision

Spectra Precision HV302 user guide

Konica Minolta CL-70F operating manual

Konica Minolta

Konica Minolta CL-70F operating manual

CARLO GAVAZZI WM30-96 - PROGRAMMING instruction manual

CARLO GAVAZZI

CARLO GAVAZZI WM30-96 - PROGRAMMING instruction manual

RUSTA 775100010101 manual

RUSTA

RUSTA 775100010101 manual

PCB Piezotronics IMI SENSORS Spindler 607A60 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS Spindler 607A60 Installation and operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.