Roiscok iDo218 User manual

iDo218
Wireless Alarm System

Contents
……………………………………………
……………………
………………………………………………
………………………………… …
…………… …
………………………………………………
………………………… ………… ……
……………………………
………………………………………………
………………………………………
…………………… ……… … …
……… ……
………………………… …… ……………
…………………………………………………
……………………………………………………
………………………………………………
…………………… ……
PACKING LIST 1
2
2
3
4
6
9
9
Arm System 20
CHAPTER 1 SUMMARY
Keys and LEDs
Main Function of iDo218
Components and Technology Data of iDo218
Technical Data 6
Professional Terms
CHAPTER 2 KEY PROGRAMMING
Keys Functions
Programming iDo218 11
Form 1.Summary of Menu 12
CHAPTER 3 SYSTEM OPERATIONS AND USAGE 19
Restore Default 19
Stay Arm 21
System Disarm 21
Arm/Disarm by Remote Controller 22
……………………
1-1
i Wireless Alarm SystemDo218

………………………………………
………………………
…………………………………………
…………………………………………………
……………… …… …………
……………………………………………
…………………………………………………
……………………………………………
……………………………………………………
……………………………………
……………
…………………………………
…………………………………………
……………………
………………………………………………
…………………………………………
…………………………………………………………
Arm/Disarm by Phone 23
Matching Remote Controller iDo104 24
Matching Detector 25
Zone Types 27
User Code and Rights Grade 27
Emergency Keys 29
Door Chime 29
Entry/Exit Delay 29
Events Log
Wrong Code Operation
Setting for against electromagnetic interference
Installation and Connection
CHAPTER 4 APPENDIX 35
iDo218UD and Remote PC Management 35
iDo218 Events
Mounting Detectors
FAQ 46
30
30
30
32
43
44
1-2
i Wireless Alarm SystemDo218

1
i Wireless Alarm SystemDo218

iDo218 wireless net-workable control panel has perfect function, is
widely used for home and commercial alarm systems. It can match
with all kinds of wireless detectors of ROISCOK and iDo. It is easy
and delightful to installers for its menu operation. The radio frequency
is 433.92MHz.
CHAPTER 1 SUMMARY
b. Signal LED
e. Move left key
h. Arm LED
k. Arm key
c. Stay arm LED
f. In and out menu key
i. Trouble LED
l. Move right key
a. Power LED
d. Stay arm key
g. Confirm key
j. Record LED
m. Buzzer and record window
Keys and LEDs
Fig 1.
2
a
b
c
d
e
f
g
h
i
j
k
l
m
i Wireless Alarm SystemDo218

Main Function of iDo218
●
●
●
●
●
●
●
●
●
●
●
62 wireless programmable zones. All the zones are defaulted as
alarm zones, and can be changed through programming.
All the zones can be divided into up to 5 partitions, partition 0-4.
Partition 1-4 can be individually armed / disarmed, also set the
daytime for automatically armed / disarmed; partition 0 is special, as
long as arm any one of the partition, partition 0 will be automatically
armed. All zones are defaulted as partition 0.
Build-in a dialer, can alarm to Central Monitor Station and / or the
users' phone numbers through PSTN/DTMF, it is compatible with
Contact ID communication format.
Alarm report can be sent to 4 follow-me phone numbers, or / and 4
central monitor station numbers at the same time. It can report 4
different Central Monitor Stations.
With grade code and duress code: Main Code, Manage Code, User
Code, One-off code and only disarm code.
Up to 127 events log which can be checked on LCD. All the events
can be chosen and sent to central monitor station, but cannot be
deleted.
With build-in recorder can record 20 seconds voice. The record
voice will play 3 times through follow-me numbers when alarm.
Alarm call has priority function.
Build-in siren driver, can drive build-in siren and 15W outside siren.
Matched for up to 10 remote controllers. Arm and Disarm iDo218 by
remote controller;
Arm and disarm iDo218 through line/mobile phone.
,
3
i Wireless Alarm SystemDo218

●
The iDo218 is powered by an adapter of 12V/2A DC, with 16 keys, a
large 4 lines LCD, 6 LED, a USB port, a phone port and a network port.
On the main board, there are a build-in siren and MIC, a connector for
outside siren and phone line and UO. Figure 1 and Figure 2
About iDo218
()
Components and Technology Data of iDo218
●
●
mentWith remote manage function, iDo218 can be remote managed
and programmed by computer.
With a Ni-MH rechargeable battery pack, the system can work more
around 36 hours after lose AC supply.
4
●Zones and Partitions
iDo218 has 62 zones, can be matched with 62 different types of
wireless detectors. All zones can be divided into four separate
partitions and a special partition. Each individual partition can be
individually armed and disarmed. Apply anti-theft protection system
composed of multi-user.
Fig 2.
a USB b Power c el Set
d Tel Line e Network
.. .T
..
abcd e
i Wireless Alarm SystemDo218

5
●
●
●
●
Every partition can set different time for auto arm/disarm.
According to the built-in clock, the system can be set up auto arm time
and auto disarm time so that one or more partitions automatically arm
and disarm in the same time every day. Each partition can be set an
independent time.
Zones Supervision
Code and Grading
Recorder, Communicator and Follow-me Number
Auto Arm/Disarm
The detector will send a report to the iDo218 to confirm itself every
2.5 hours. The iDo218 will alarm to the central monitor station if no
report received in 16 hours.
iDo218 can be set up 10 grading codes. Including a master code, an
administrator code, and six user's codes, an only arm code and one-off
disarm code. All the code can automatically generate a duress code.
Master code has the top grade. The administrator code can be used to
determine the permissions to each user.
IDo218 has build-in recorder with 20 seconds.
IDo218 has build-in digital communicator with Contact ID
communication format. It can be set up to 4 central monitor station
numbers. When alarm, iDo218 will report alarm information to the
central monitor station through telephone (PSTN/DTFM). It also can
be set up to 4 follow-me numbers. It can send pre-recorded voice to
each follow-me number when alarm.
iDo218 can be programmed to one or several partitions which can auto
arm/disarm at the same time everyday according to the build-in clock.
i Wireless Alarm SystemDo218

6
Input power
Standby battery
External siren driver
Maximum consumption
Minimum consumption
Dimensions
DC12V 2A
196×167×39 mm
40mA, under battery supply
Basic 45mA, LCD backlight 60mA
and internal siren 5mA
DC12V15W
9.6VDC1500mAH
Ni-MH rechargeable battery pack.
Technical Data
●
●
Arm/Disarm
Events Log
User can arm/disarm iDo218 by the following three ways: keys,
remote controller, line phone or/and mobile phone.
iDo218 can save up to 127 events, including arm, disarm, alarm, etc.
Professional Terms
●Zone Types
There are 9 zone types as: alarm, transfer, close, Stay, 24 hours, gas,
medical, panic and fire. The transfer zone is used only for the radio
repeater.
Alarm zone could be set as entry/exit delay zone and instant zone.
When trigger delay zone, the system will alarm after the delay time
When trigger instant zone, the system will alarm immediately.
;
i Wireless Alarm SystemDo218

7
24 hours' zones can not be disarmed, such as 24 hour, gas, medical,
emergency and fire.
Stay Zone means when press [STAY] to arm the system, they are
bypassed and cannot be armed.
Close zone cannot be armed anytime.
Each wireless detectors / wireless repeater has a fixed and unique ID
code. Before use, you must first match this ID to the control panel.
Otherwise, the signal from detector or repeater would not be received
by the control panel. This process is called Matching.
All the happened by system called event, including disarm, arm,
alarm, iDo218 power low, detector power low, detector
communication failure, clock failure, siren failure and so on.
ARM means start the warning status for part or all of the zones,
DISARM means close the warning for part or all the zones.
During arming, iDo218 will alarm when any detector is triggered.
During disarming, iDo218 will not alarm when any detector is
triggered.
User can set 4 groups of users' telephone (line phone or mobile phone)
numbers. iDo218 will send alarm voice to some phone number(s)
when alarm. The numbers are called follow-me number.
Detector / Repeater Matching
Event
Arm/Disarm
Follow-me number
status
●
●
●
●
i Wireless Alarm SystemDo218

8
●
●
●
●
●
●
disarm and auto-disarm.
There are two arm keys: [ARM] and [STAY]. When press [ARM] to
arm, all the zones/whole system will be armed. When press [STAY] to
arm, all the zones except the stay zones will be armed.
Zone which set as Close zone cannot be armed at any time.
Arm and Stay
Close Zone
CMS Number
UO
Correlative Detector
Partition
User can set 4 groups of CMS (central monitor station) telephone
numbers. iDo218 will send alarm information through the 4 numbers
when alarm. The numbers are CMS number.
When there is an alarm or any event, iDo218 could send the telecom
number by UO correlative output port, these telecom numbers could
startup other equipment or function of iDo218, we called as UO
correlative. For example alarm correlative, arm correlative, system
failure correlative and so on.
iDo218 can designate two groups of correlative detectors. Each group
has two detectors. The iDo218 would alarm just when the two
detectors are both triggered in the correlative time. There are two
types of correlative detectors that one type is with directional
immunity and the other is without directional immunity.
All the zones of iDo218 could be divided into 5 groups at most, called
partition. Each one can be operated separately, such arm, auto-arm,
i Wireless Alarm SystemDo218

9
CHAPTER 2 KEY PROGRAMMING
iDo218 can be programmed and PC. To program iDo218
through keypads as following menu.
The programming menu of iDo218 including 7 sub-menus:
through keys
0) Help
1) Probe/Transfer Detector/Repeater
2) Setting Code
3) Set Phone/Partition Number
4) Check
5) On/Off Setting
6) Other setting
Keys Functions
●
●
●
ARM
Use for arm the system. Change data or/and turn to another submenu
when programming, such as On/Off and choice partition.
Use for stay arm the system, turn to another submenu when
programming.
When system arming, it is used for confirmation input code and then
STAY
#/ Confirmation key
i Wireless Alarm SystemDo218

confirm disarm system; Use for confirm an operation, confirm data
and save under the programming.
Use for enter into programming when system is disarming; Use for
return back to last menu or exit the programming.
Under programming:
1) Move the cursor right.
2) To next menu.
3) To next line in HELP menu.
Under programming:
1) Move the cursor right.
2) To last menu.
3) TolastlineinHELPmenu.
Use for input the code, programming and other operation for numbers.
●
●
●
●
*/ Enter /return back key
[→] key
[←] Key
Number key
10
i Wireless Alarm SystemDo218

Help
12 39:
0
↓
Under disarm status press [*] to enter programming menu. If do not
press [ARM], [STAY] or [*] the screen will display Press [*] Enter
Into Programming.
,
:
When programming, the screen displays:
Through the board at this time with the keys on the keyboard to
program operation, all operations menu is as follows:
11
03 12
ROISCOK
iDo218Alarm System
Programming iDo218
When power on, the LCD screen displays as following:
i Wireless Alarm SystemDo218

12
Partition
Move cursor by [←][→], enter detector number. Select
partition number by [ARM] or [STAY], and then
confirm by [#].
2
All detectors in
partition 0
00-00 0m
00-00 0m
User can setup 2 groups of correlative zones:
For example 01-02 2m means 01 and 02 zones are
correlative zones. The iDo218 will alarm when both of
the two zones are triggered in 2 minutes.
For example: 01[→] 02 2m means 01 and 02 zones
correlative by sequence. The iDo218 will alarm when
zone 01 triggered before 02.
“>”or “-”decide correlative zones if have sequence,
use [ARM] key to exchange.
:
Correlative Zone
0
0
1
Help
Auto Arm
Press [→] to next line, press [←]to last line.
Hot Key Item Default Instruction
Setting for Zones, partitions and repeaters.
Partition can be set time for arm/disarm by automation,
according to the form as HH MM[→]HH MM. Before
[→], HH:MM means time for arm; after [→], HH:MM
means time for disarm. (Hour: Minute)
::
Detector/Repeater
Form 1.Summary of Menu
i Wireless Alarm SystemDo218
1

3
The system needs to a proper Entry Delay time for user
to enter the protected area and disarm the system
without triggering an alarm. Time setting range: 00-90
seconds.
The system needs to set a proper Exit Delay time for
user to arm the system and get out of the protected area
without triggering an alarm. Time setting range: 00-90
seconds.
4
No delay time
No delay time
Intrusion alarm type
5
There 9 types of zone as: alarm, transfer, close, Stay,
24hr, gas, medical, panic and fire. And the transfer is
used for radio repeater.
6
In this mode, let the wireless detectors and/or repeater
send a signal to the iDo218. After received the
matching codes, all the wireless detectors and/or
repeater will be matched in from 01 to 62. Exchange a.
or b. by [→] or [←]
a. Detector matching
b. Repeater matching
2
7
Cancel all the matched detectors. To be On the safe
side, the system will ask for a reconfirmation.
8Input the detector number and [#] to cancel the detector
Entry delay
Entry delay
Zone Type
Matching
Cancel All
Cancel One
Setting Code All the codes are made up of 4-6 digits.
Hot Key Item Default Instruction
13
i Wireless Alarm SystemDo218

4
5
6
7
8
9
3
0
1
2
3
3 times
3 times
The code is made up of 4-6 digits.
The code is made up of 4-6 digits.
The code is made up of 4-6 digits.
The code is made up of 4-6 digits.
The code is Only for arming, it is made up of 4-6 digits.
The code is Only for One-Off disarmming. It is made up of 4-6 digits.
There are 4 follow-me phone numbers, press ARM or
STAY to shift from One number to another.
There can be set up 4 CMS Numbers (Center Monitor
Station), use ARM, STAY to shift from one number to
another.
Dialing Follow-me Number Times. Up to 9 times.
Dialing CMS numbers Times. Up to 9 times.
Hot Key Item Default Instruction
0
1
2
1234 The code is made up of 4-6 digits.
The code is made up of 4-6 digits.
The code is made up of 4-6 digits.
User Code 3
User Code 4
User Code 5
User Code 6
Code for Arm Only
One-Off Code
Set Phone/Partition
Number
Set Follow-me
Set CMS Numbers
Follow Times
CMS Times
Main Code
Manage Code
User Code 2
User Code 2
3The code is made up of 4-6 digits.
14
i Wireless Alarm SystemDo218

0
4
The iDo218 can save 127 events.
1
2
3
5
When checking, the iDo218 will display the status of DC,
phone line, battery and siren.
Use to turn on or off some functions
0Set the buzzer On or Off when operating by keys.
Exchange by [ARM] or [STAY].
User can check each detector's Type, Entry/ Exit Delay Time,
Partition, Auto-arm Timeetc., use ARM, STAY to shift
between detectors, use [→] or [←] to shift between the
detector's attributes.
Check each door chime's corresponded detector and the door
chime's status. Use [→] and/or [←] to shift between the door
chimes.
4
5
6
Partition 0 is armed simultaneously when arm any other partition(s).
7
8
Check
Event
Trouble
Detector
Door Chime
On/Off Setting
Buzzer
Partition 0 No.
Partition 1 No.
Partition 2 No.
Partition 3 No.
Partition 4 No.
On
0000
0000
0000
0000
0000
Hot Key Item Default Instruction
15
i Wireless Alarm SystemDo218

16
2On
Quick Arm
For set quick arm or quick stay:
a.Quick arm
b.Quick stay
On:Press [ARM] to arm the system directly
Off:Press [ARM], then input code to arm the system
On:Press [STAY] to arm the system directly
Off:Press [STAY], then input code to arm the system
Exchangea.andb.by[→][←],andexchangeon/offby
[ARM] or [STAY]
1Chime
Set each door chime's corresponded zone and its On/Off.
Max 8 door chimes are allowed. Such as:
1 door (- -) Detector Off
Hot Key Item Default Instruction
Power trouble
3On
On When the system checked there is a DC trouble, it will
alarm to CMS
Off When the system checked there is a trouble, it would
not alarm to CMS
:
:
Supervision
4Off
On iDo218 will report to the CMS after no signal
from a detector in 16 hours;
:
:Off No any report to CMS
5
Siren trouble
Siren alert On
On
On When siren trouble the iDo218 will sen report to the
CMS;
Off No report to the CMS when there is any trouble of siren
:d
:
On: When arm/disarm, the siren will di- to alert.
Off: When arm/disarm, the siren will no di- to alert.
i Wireless Alarm SystemDo218

17
6
7
8
9
6
0
1
Off
On
Off
…
12 seconds
2
Display
Stop by disarm
Remote manage
Noise Adjust
Other Setting
Set Date
Ring Time
Record
Controller match
3
On When dialing, the LCD will display the dialing status ,if
the dialing is successful etc.,
Off When dialing, nothing will be displayed On LCD
:
:
On When disarm, the iDo218 will stop dialing CMS and
Follow-me numbers
Off When disarm, the iDo218 will still finish the dialing
:
;
:
On Accept remote management by PC;
Off Prevent remote management by PC
:
:
Set the system recognized the value of environmental
electromagnetic interference
Set the system date and time:
Format: MM(month)/DD(date)/YY(year) HH(hour): MM(minute)
The ringing time can be from 00-90 seconds
User can record voice through the microphone in the
iDo218, 20 seconds.
Use for match or/and cancel detectors, exchange a. or b. by[→][←]:
a. Controller match
After matched, the controllers could work with iDo218. Up to 10
controllers can be matched.
b. Controller cancel
Cancel all of the matched controllers in one time.
Hot Key Item Default Instruction
i Wireless Alarm SystemDo218