Rossmax RA600 User manual

To change the Unit from °C to °F:
1. Turn off the device.
2. Hold down the “Start” button, then press and
hold the“ON/OFF/Memory” button until the LCD
shows °C.
3. Press the “Start” to change the °C to °F, then
release the “Start” button.
4. During the setting adjustment, each old or new
temperature scale setting will be ashing for 6
seconds. After 6 seconds without changing, the
temperature scale adjustment will be completed,
and the unit will be entered into measurement
mode.
b. Replace the probe cover after each use to ensure an accurate
reading and avoid cross contamination.
c. This thermometer must only be used with rossmax probe
covers, other covers can lead to inaccuracy. If running out
of probe covers, please contact with the original seller or dis-
tributor for buying new probe covers.
4. Measuring the ear temperature: Use the index nger to trigger, by
pressing “Start” button, a long beep will be sounded when meas-
urement is done.
5. For the next measurement, remove the used probe cover and put
on a new one.
6. Power off: If left idle for more than 1 minute, device will automati-
cally shut off for extending battery life. Or press “On/Off/Memo-
ry” button for at least 3 seconds to turn the device off.
7. Fever alarm: When the measuring temperature is higher than 37.5
°C(93.2°F), the reading will ash, the backlight will be enabled, and
4 short beeps will be sounded. If measuring temperature is higher
than 42.2 °C(108°F), the display will show “Hi”, the backlight will
be enabled, and 4 short beeps will be sounded.
a. It is recommended that you measure 3 times with the same
ear within a short period of time. If the 3 consecutive meas-
urements are different, select the highest temperature.
b. To avoid the risk of cross contamination, please clean the probe
according to “Clean and Storage“ section after each use.
www.rossmax.com
LCD
display
Battery
cover
ON/OFF/
Memory
button
Probe
Ear Battery
Probe
cover °C/°F scale
Temperature
display
Probe
cover
Clockwise
way to lock
Probe
Instruction Manual
Model: RA600
1. To achieve accurate readings, make sure a new, clean probe cover is
in place before each measurement and the ear canal is clean.
a. Install the probe cover by clockwise rotating then x it.
b. Remove the probe cover by anti-clockwise rotating then releas-
ing it.
2. Press the “On/Off/Memory” button, the thermometer is ready
for use after the ear icon is ashing, two beeps are sounded, and
three dash segments are appeared.
3. Gently pull the ear back to straighten the ear canal and snugly posi-
tion the probe into the ear canal, aiming towards the membrane of
the eardrum to obtain an accurate reading.
a. Before measurement, correct installation of the probe cover
ensures accurate measurement.
There are total 9 set memories for measurement records. If the read-
ing of the thermometers is within the normal temperature range of
34 °C to 42.2 °C (93.2 °F to 108°F ), when the measurement is done,
the measurement data is saved into memory.
• Press “On/Off/Memory” button to repeatedly to recall each tem-
perature memory.
• It means measurable and reminds to use a probe cover for
measurement.
• When battery icon always appears, please replace the battery.
How to use the RA600 Infrared Ear Thermometer
LCD display
Memory function
Cleaning and storage
Please read the instruction manual carefully before using the
product and be sure to keep this manual.
1. Turn off the device.
2. Hold down the “Start” button, then press and hold the“ON/OFF/
Memory” button until the LCD shows °C.
3. Press the “ON/OFF/Memory” change beep sound from on to off, then
release the “ON/OFF/Memory” button.
4. After 6 seconds without changing, the beep On/Off setting will be
completed, and the unit will be entered into the measurement mode.
Enabling or disabling the beep sound
The Rossmax Infrared Ear thermometer has been carefully devel-
oped for accurate, safe and fast temperature measurements in the
ear.
It is a non-invasive ear thermometer using an infrared detector to
detect body temperature from the auditory canal for adult and
child.
• The quality of the infrared ear thermometer has been veried and con-
forms to the provisions of the EC council directive 93/42/EEC(Medical
Device Directive) Annex I essential requirements and applied harmo-
nized standards. EN 12470-5: 2003 Clinical thermometers-Part 5: Per-
formance of infrared ear thermometers (with maximum device.)
• This thermometer converts the ear temperature to display its “oral
equivalent.” (according to the result of the clinical evaluation)
RA600 Infrared Ear Thermometer
Switching between temperature scale
Fahrenheit and Celsius
1. This thermometer is equipped with one lithium cell (CR2032).
2. Turn off the thermometer before replacing the battery.
3. Open the battery cover: Hold the device and ip the battery out
by sticking the pen tip into the battery storage well as illustrated.
4.Insert a new battery and ensure the battery positive polarity is
facing upward.
5. Place back the battery cover.
* The positive (+) side up and the negative (-) side pointed down.
Change the battery
Probe
cover
Start
button
Error message Problem Solution
bi-bi-bi
The ambient tem-
perature is not
within the range
between 10°C~40°C
(50°F~104°F)
Allow the thermometer
to keep in a room for at
least 30 minutes at room
temperature: 10°C to
40°C (50°F to 104°F)
bi-bi-bi
The system is not func-
tioning properly.
Unload the battery, wait
for 1 minute and re-
power it. If the message
reappears, contact the
retailer for service.
Device can not be pow-
ered on to the ready
stage.
Change with a new bat-
tery. If the message reap-
pears, contact the retailer
for service.
bi-bi-bi-bi
Temperature taken is
higher than 42.2°C
(108.0°F)
Ensure no break or dirt
of the probe cover and
take a new temperature
measurement.
bi-bi-bi-bi
Temperature taken
is lower than 34°C
(93.2°F)
Make sure the probe
cover is clean and take a
new temperature meas-
urement.
Troubleshooting
EN
If you continuously obtain different measurement results, it is recom-
mended that you use Scanning Mode to measure.
Measuring the ear temperature: Use the index nger to trigger, press
and hold the “Start” button for 3 seconds to take measurement.
During the measuring process, gently pivoting the probe side-to-side
to view the entire ear canal or in order to nd the highest tempera-
ture. Release the “Start” button until hearing a long beep sound and
the measurement is completed.
Scanning Mode The probe is the most delicate part of the thermom-
eter. Use with care when cleaning the lens to avoid
damage.
1. Please use the cotton swab with the Alcohol to clean
the lens (on the inside of the probe).
2. Allow the probe to fully dry for at least 5 minutes.
a. Please check the device if it falls and damages. If you can’t
make sure of it, please send the complete device to the
nearest retailer for recalibration.
b. Keep the unit dry and away from any liquid and direct sun-
light. The probe should not be submerging into liquids.

This instrument is covered by a 5 year guarantee from the
date of purchase, batteries and accessories are not included.
The guarantee is valid only on presentation of the guarantee
card completed by the dealer conrming date of purchase or
the receipt. Opening or altering the instrument invalidates the
guarantee. The guarantee does not cover damage, accidents
or non-compliance with the instruction manual. Please contact
Rossmax Service.
Specication
Temperature measurement
range
34.0~42.2°C(93.2~108.0°F)
Accuracy ±0.2°C (0.4°F) during 35.0~42.2°C
(95~108.0°F)
±0.3°C (0.5°F) for other range
Operating temperature
range
10 ~ 40°C (50~104°F), RH<=95%
Storage and transportation
temperature
Temperature:-25~55°C (-13~131°F),
RH <=95%
Memory 9 set
Display resolution 0.1
Battery 3V, lithium CR2032 x 1
Weight (with battery) 55g
Size 12.0cm(L) x 3.5cm(w) x 2.8cm(H)
Probe cover 11 pcs
Auto shut down 60 sec.
Battery life 3000 consecutive measurements or 1
year with 1-2 measurements per day
including stand-by mode.
Safety classication Type BF equipment
Clinical repeatability 0.08°C (< 1 year old)
0.10°C (1~5 years old)
0.07°C (> 5 years old)
*Dispose of device and batteries according to local regulations
1. Besides the oral temperature, the body temperature measured
by ear may be different from measurements taken by rectal or
axillary. Therefore, there is no any meaning to compare them.
Take the temperature periodically to nd out the normal ear
temperature reading , then use that reading as the basis for
comparison with any measurement taken when you suspect
a fever.
2. This thermometer is designed for ear temperature measurement.
Do not use this thermometer for other body site measurement.
3. Keep the unit dry and away from where it might be exposed to
moisture, liquids, direct sunlight, high temperature, high humidity,
or excessive dust.
4. This device is not shock-protected. Do not drop, heavily pressure
the unit or fall from high place.
5. Do not bend the device.
6. Do not disassemble or make modications on the device.
7. Please do not dispose of the product in the household waste at
the end of its useful life. Disposal can take place at your local
retailer or at appropriate collection points provided in your country.
8. Do not boil the probe.
9. Do not use the device if it operates abnormally or error massage
is showed.
10. Do not use thinner or benzene to clean the device.
11. Wipe the device clean before storing.
12. When taking the device from storage below or above 10~
40°C(50~104°F), place it in 10~ 40°C(50~104°F) temperature
range for at least 30 minutes before use.
13. Remove the battery if this device is not used for a period of time.
14. If this device is used according to the operation instruction, periodic
re-calibration is not required. If you still have questions, please send
the complete device to dealers.
15. Please note that this is a home healthcare product only, and it is
not intended to serve as a substitute for the advice of a physician
or medical professional.
16. Do not use this device for diagnosis or treatment of any health
problem on disease. Measurement results are for reference
only. Contact your physician if you have or suspect any medical
problems. Do not change your medications without the advice of
your physician or healthcare professional.
17. This device may not meet its performance specication if stored
or used outside temperature and humidity ranges specied in
specications.
18. Battery should neither be charged nor placed into the extreme
environment, or it may explode.
19. The thermometer contains small parts (ex: battery, etc.) that can
be swallowed by children. Therefore never leave the thermometer
unattended to children.
20. After wearing the probe cover, the ear thermometer probe must be
vertically and snugly inserted into the ear channel so as to get the
correct temperature reading.
21. Be sure to consult a doctor if you feel that your health is in poor
condition.
22. Do not judge your health only on the presence or absence of a
fever.
Caution
Warranty
IN0RA6000000000XX
OBM_IB_RA600_EN_ver1303
Product Information
Date of purchase:
Store where purchased:
Price Paid (excl. Tax):
Purchase for:
Low battery: Battery
icon is ashing, still can
be measurable.
Suggest to replace the
battery.
Dead battery: Battery
icon always enabled,
no more measure-
ments are possible.
Replace the battery
Electrical fast
transient/burst IEC
61000-4-4
± 2kV for power
supply lines
± 1kV for input/
output lines
Not applicable
Not applicable
Mains power quality should be
that of a typical commercial or
hospital environment.
Surge IEC 61000-4-5 ± 1kV line(s) to
line(s)
± 2kV line(s) to
earth
Not applicable
Not applicable
Mains power quality should be
that of a typical commercial or
hospital environment.
Voltage Dips, short
interruptions and
voltage variations on
power supply input
lines IEC 61000-4-11
<5% UT(>95% dip
in UT) for 0,5 cycle
40% UT(60% dip
in UT) for 5 cycles
70% UT(30% dip
in UT) for 25 cycles
<5% UT(>95% dip
in UT) for 5 s
Not applicable
Not applicable
Not applicable
Not applicable
Mains power quality should be
that of a typical commercial or
hospital environment. If the user
of the RA600 series requires
continued operation during
power mains interruptions, it is
recommended that the RA600
series be powered from an
uninterruptible power supply or
a battery.
Power frequency
(50/60 Hz) magnetic
eld IEC 61000-4-8
3 A/m 3 A/m The RA600 power frequency
magnetic elds should be at
levels characteristic of a typical
location in a typical commercial
or hospital environment.
NOTE: UT is the a.c. mains voltage prior to application of the test level.
Recommended separation distance between portable and mobile RF communications equip-
ment and the RA600
The RA600 is intended for use in an electromagnetic environment in which radiated RF
disturbances are controlled. The customer or the user of the RA600 can help prevent
electromagnetic interference by maintaining a minimum distance between portable and
mobile RF communications equipment (transmitters) and the RA600 as recommended
below, according to the maximum output power of the communications equipment.
Rated maximum
output power of
transmitter / W
Separation distance according to frequency of transmitter / m
150 kHz to 80
MHz / d=1,2√P
80 MHz to 800 MHz
/ d=1,2√P
800 MHz to 2,5 GHz /
d=2,3√P
0,01 N/A 0,12 0,23
0,1 N/A 0,38 0,73
1 N/A 1,2 2,3
10 N/A 3,8 7,3
100 N/A 12 23
For transmitters rated at a maximum output power not listed above, the recommended
separation distance d in metres (m) can be estimated using the equation applicable to
the frequency of the transmitter, where P is the maximum output power rating of the
transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency
range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation
is affected by absorption and reection from structures, objects and people.
Guidance and manufacturer’s declaration-electromagnetic emissions
The RA600 is intended for use in the electromagnetic environment specied below.
The customer or the user of the RA600 should assure that it is used in such an environment.
Emission test Compliance Electromagnetic environment-guidance
RF emissions CISPR 11 Group 1 The RA600 uses RF energy only for its internal func-
tion. Therefore, its RF emissions are very low and are
not likely to cause any interference in nearby elec-
tronic equipment.
RF emissions CISPR 11 Class B The RA600 is suitable for use in all establishments,
including domestic establishments and those directly
connected to the public low-voltage power supply
network that supplies buildings used for domestic
purposes.
Harmonic emissions
IEC 61000-3-2 Not appli-
cable
Voltage uctuations/icker
emissions IEC 61000-3-3
Not appli-
cable
Guidance and manufacturer’s declaration-electromagnetic immunity
The RA600 is intended for use in the electromagnetic environment specied below.
The customer or the user of the RA600 should assure that it is used in such an environment.
Immunity
test
IEC 60601
test level
Compliance
level
Electromagnetic environment-guidance
Conducted
RF IEC
61000-4-6
Radiated RF
IEC 61000-
4-3
3 Vrms
150 KHz to
80 MHz
3 V/m
80MHz to
2,5 GHz
Not appli-
cable
3 V/m
Portable and mobile RF communications equip-
ment should be used no closer to any part of the
RA600 series, including cables, than the recom-
mended separation distance calculated from
the equation applicable to the frequency of the
transmitter.
Recommended separation distance:
d = 1,2 √P
d = 1,2 √P 80MHz to 800 MHz
d = 2,3 √P 800MHz to 2,5 GHz
Where P is the maximum output power rating
of the transmitter in watts (W) according to the
transmitter manufacturer and d is the recom-
mended separation distance in metres (m).
Field strengths from xed RF transmitters, as
determined by an electromagnetic site survey, a
should be less than the compliance level in each
frequency range. b
Interference may occur in the vicinity of equip-
ment marked with the following symbol:
NOTE1: At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE2: These guidelines may not apply in all situations. Electromagnetic propagation
is affected by absorption and reection from structures, objects and people.
a. Field strengths from xed transmitters, such as base stations for radio (cellular/cord-
less) telephones and land mobile radios, amateur radio, AM and FM radio broadcast
and TV broadcast cannot be predicted theoretically with accuracy. To assess the elec-
tromagnetic environment due to xed RF transmitters, an electromagnetic site survey
should be considered. If the measured eld strength in the location in which the
RA600 series is used exceeds the applicable RF compliance level above, the RA600
series should be observed to verify normal operation. If abnormal performance is
observed, additional measures may be necessary, such as reorienting or relocating
the RA600 series.
b. Over the frequency range 150 kHz to 80 MHz, eld strengths should be less than
3 V/m.
Guidance and manufacturer’s declaration-electromagnetic immunity
The RA600 is intended for use in the electromagnetic environment specied below.
The customer or the user of the RA600 should assure that it is used in such an environment.
Immunity test IEC 60601 test level Compliance
level
Electromagnetic environment-
guidance
Electrostatic discharge
(ESD) IEC 61000-4-2
± 6 kV contact
± 8 kV air
± 6 kV contact
± 8 kV air
Floors should be wood, concrete
or ceramic tile. If oors are
covered with synthetic material,
the relative humidity should be
at least 30%
EMC guidance and manufacturer’s declaration
www.rossmax.com
Rossmax International Ltd.
12F., No. 189, Kang Chien Rd., Taipei, 114, Taiwan.
Rossmax Swiss GmbH,
Tramstrasse 16, CH-9442 Berneck, Switzerland
Other Rossmax Thermometer manuals

Rossmax
Rossmax TG120 User manual

Rossmax
Rossmax RA600 User manual

Rossmax
Rossmax HC700 User manual

Rossmax
Rossmax RA500 User manual

Rossmax
Rossmax TG380 User manual

Rossmax
Rossmax HD500 User manual

Rossmax
Rossmax TG100 User manual

Rossmax
Rossmax TG100 User manual

Rossmax
Rossmax TG100 User manual

Rossmax
Rossmax HC700 User manual