Rotech Sentinel BOB50 Series User manual

Installation Instructions
Please read these instructions fully before installing
Vehicle Access Control
Pedestrian Access Control
Safety & Security Equipment
t: +61 07 3205 1123 www.rotech.com.au e: [email protected]
Sentinel BOB50 Linear
Swing Gate Operator v03/23

3
455 / 485 / 520
857
100
87
48
70
107
980
Overall dimensions

4
1
X Y ZKM*
max.
L (m) P (kg)
90 150 150 75 695 90 25”
2,5 400
3 350
3,5 300
4* 250
90 225 225 130 625 155 38”
2,5 500
3 450
3,5 400
4* 350
4,5* 300
5* 250
100 200 200 110 650 130 34”
2,5 500
3 450
3,5 400
4* 350
4,5* 300
5* 250
110 175 175 90 680 110 30”
2,5 400
3 350
3,5 300
4* 250
Max wing dimensions
Opening time
Max Opening
.
X
K
P S
Y
MZ
M
Y
X
90°
110°
max
M= +20mm / K= -10mm
Fig. 1a
Fig. 1b
*
* It is advisable to use an electric lock

5
3
2
V1
V2
BB
P
F
D
P
S V
R
C
T
Level.
Weld or bolt on
mounting brackets
Grease
Weld or bolt on
mounting brackets

6
4
V
P
Position 1 (PG13,5)
Position 2 (PG11)

7
5
M+
M-
COM
FCO
FCC
ENCODER signal
ENCODER positive
ENCODER negative
Black wire
Red wire
b
a
8
7
6
5
4
3
2
1
Encoder
M
ba
1 2 6 7 8

8
34
2
1
5
3x1,5 min.
230Vac
2
1
2x1,5
2x0,5
2x0,5
2x2,5~4
2x2,5~4
3x0,5
3x0,5
4x0,5
RG 58
Legenda:
1 Motoreducer BOB5024
2 Photo-electric cells FTC/FTM
3 Key selector CH/TO.KEY (external)
or digital keyboard
4 Flash-light LAMPI24
5 Electronic board BRAIN24.
Wire diagram
The power cables must be kept separated from the auxiliary cables.For
cable length lower than 5m, use a cable 2x2.5sqmm. For cable length
from 5 to 10 m use a cable 2x4sqmm. Cables longer than 10m are not
recommended to connect control unit and motor.

11
WARNING
The product shall not be used for purposes or in ways
other than those for which the product is intended for and
as described in this manual. Incorrect uses can damage
the product and cause injuries and damages.
The company shall not be deemed responsible for the
non-compliance with a good manufacture technique of
gates as well as for any deformation, which might occur
during use.
Keep this manual for further use.
Qualified personnel, in compliance with regulations in
force, shall install the system.
Packaging must be kept out of reach of children, as it can
be hazardous. For disposal, packaging must be divided
the various types of waste (e.g. carton board, polystyrene)
in compliance with regulations in force.
The installer must supply all information on the automatic,
manual and emergency operation of the automatic sy-
stem and supply the end user with instructions for use.
;An omnipolar switch/section switch with remote
contact opening equal to, or higher than 3mm
must be provided on the power supply mains..
Make sure that before wiring an adequate differential
switch and an overcurrent protection is provided.
Pursuant to safety regulations in force, some types of in-
stallation require that the gate connection be earthed.
During installation, maintenance and repair, cut off power
supply before accessing to live parts.
Descriptions and figures in this manual are not binding.
While leaving the essential characteristics of the product
unchanged, the manufacturer reserves the right to modify
the same under the technical, design or commercial point
of view without necessarily update this manual.
EC Declaration of Conformity
Manufacturer: Automatismi Benincà SpA.
Address: Via Capitello, 45 - 36066 Sandrigo (VI) - Italia
Herewith declares that: the operator for hinged gates model BOB5024 / BOB5024E.
is complying with provisions set forth by the following other EC Directive:
- DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL
of 15 December 2004, on the harmonisation of the laws of Member States relating to
electromagnetic compatibility and which cancels Directive 89/336/EEC, according to the
following harmonised regulations: EN 61000-6-2:2005, EN 61000-6-3:2007.
Benincà Luigi, Legal responsible.
Sandrigo, 10/06/2010.

12
Introduction
t#FGPSFJOTUBMMJOHUIFTZTUFNSFBEUIFJOTUSVDUJPOherein.
t*UJTNBOEBUPSZOPUUPVTFUIF#0##0#&item for applications different from those indicated
in the instructions herein.
t4VQQMZUIFFOEVTFSXJUIJOTUSVDUJPOTGPSVTJOHUIJTsystem.
t
The end user should receive special instruction manual.
t"MM#FOJODËJUFNTBSFDPWFSFECZBOJOTVSBODFQPMJDZfor damages and injuries caused by manufacture
faults. It is however required that the machine
bear the CE marking and original Benincà parts be
used.
General information
To ensure a good operation of these automatic devices,
the gate to be automated should meet the following
requirements:
- good strength and stiffness.
- hinges should have a minimum backlash and allow
for smooth and regular manual operations.
- when closed, the gate leaves should correctly
overlap for their entire height.
How to install the automatic system
Calculate the height of the system from the ground
(it is advisable to define a position as much centred
as possible with respect to the main door and in
correspondence with a strong cross girder). Weld the
plate P, following measures in Fig. 1.
With the door closed, weld bracket S to a cross beam
of the main door or other element with equal strength,
according to measures shown in Fig. 1. Keep in mind
that, when carrying out this operation, the actuator
should not be totally in a stroke end position.
Remove the cover C by loosening the screw F. Then
fix the actuator to the plate P by means of the screw
T and the nut D (Fig. 2). Lock the actuator to plate S
by means of screw V and washer R.
The holes in the acturator (Fig. 1a-1b) help to keep to
the optimum installation measures.
How to adjust the mechanical stoppers
The actuator is provided with adjustable mechanical
stoppers in the opening and closing phases. The system
is adjusted by suitably positioning the “Open” and
“Close” mechanical locks, as shown hereunder (Fig.3):
1) Unlock the automatic system by using the special
release lever, as shown in the instructions for the
user (page 21-22).
2) Close the door/gate leaf.
3) Loosen screws V1 and move the “Close” lock until
it reaches the pivot P, then tighten screws V1.
4) Open the door/gate leaf.
5) Loosen screws V2 and move the “Open” lock until
it reaches the pivot P, then tighten screws V2.
6) Reset the automatic operating mode.
In the BOB 524 version, two limit micro-switches are
provided fixed to the mechanical stoppers.
The micro-switches trigger slightly in advance with
respect to the mechanical stop.
Connections
1) The special plate P (Fig. 4) allows for using a link for
sheath or cable gland PG11, or PG13,5. Once the
type of cable gland is applied to the plate, fix the
latter to the adaptor cover by means of screws V.
2) BOB 524: carry out the wiring by referring to the
wire diagram shown in Fig 5a.
3) BOB 524E: carry out the wiring by referring to wire
diagram shown in Fig 5b.
4) It is mandatory to provide for ground by using the
special GND terminal.
WARNING
The insurance policy, which covers any damages or
injuries caused by manufacture faults, requires that
the installation comply with regulations in force and
Benincà original accessories be used.
TECHNICAL DATA
BOB5024
BOB5024E
Power supply 24Vdc
Absorbed rating 120 W
Absorbed current 6 A
Thrust 2000 N
Jogging intensive
Protection degree
Operating temperature -20°C / +70°C
Door leaf max. weight 500 kg
Useful stroke:
- with 2 mechanical stoppers
- with 1 mechanical stopper
- without mechanical stoppers
455 mm
485 mm
520 mm
Translation speed 0,8 m/min
Noise level <70 dB
Lubrication Permanent
grease
Weight 11,6 kg
IP44

21
Norme di sicurezza
t/POTPTUBSFOFMMB[POBEJNPWJNFOUPEFMMBQPSUBt
Non lasciare che i bambini giochino con i comandi o in prossimità delle ante.
t*ODBTPEJBOPNBMJFEJGVO[JPOBNFOUPOPOUFOUBSFEJSJQBSBSFJMHVBTUPma avvertire un tecnico specializzato.
manualmente le ante procedere come segue:
t
aprire lo sportellino di protezione del meccanismo di sblocco (fig. A);
t
Inserire la speciale chiave di sblocco fornita in dotazione e ruotarla di
90°, come indicato dalla freccia sul carter evidenziata in figura B;
tÒPSBQPTTJCJMFBQSJSFDIJVEFSFNBOVBMNFOUFMBOUBtQFSSJQSJTUJOBSFJMGVO[JPOBNFOUPBVUPNBUJDPSJQPSUBSFMBDIJBWFEJManutenzione
t$POUSPMMBSFQFSJPEJDBNFOUFMFGmDJFO[BEFMMPTCMPDDPNBOVBMFEJemergenza.
t"TUFOFSTJBTTPMVUBNFOUFEBMUFOUBUJWPEJFGGFUUVBSFSJQBSB[JPOJt-BUUVBUPSFOPOSJDIJFEFNBOVUFO[JPOJPSEJOBSJFUVUUBWJBÒOFDFTTBSJPSafety rules
t%POPUTUBOEJOUIFNPWFNFOUBSFBPGUIFEPPSt%POPUMFUDIJMESFOQMBZXJUIDPOUSPMTBOEOFBSUIFEPPSt4IPVMEPQFSBUJOHGBVMUTPDDVSEPOPUBUUFNQUUPSFQBJSUIFGBVMUbut call a qualified technician.
Manual and emergency operation
In the event of power failure or fault, to manually open and close
UIFEPPSHBUFQSPDFFEBTGPMMPXTtPQFOUIFQSPUFDUJPOEPPSPGUIFSFMFBTFEFWJDF'JH"t
introduce the special release key supplied and turn it by 90°, as shown
by the arrow on the removable cover highlighted in Figure B;
tOPXUIFEPPSDBOCFPQFOFEDMPTFECZIBOEtUPSFTFUUIFBVUPNBUJDPQFSBUJPONPWFUIFSFMFBTFLFZUPUIFinitial position;
tSFNPWFUIFSFMFBTFMFWFSBOEDMPTFUIFQSPUFDUJPOEPPSMaintenance
t
Every month check the good operation of the emergency manual release.
t*UJTNBOEBUPSZOPUUPDBSSZPVUFYUSBPSEJOBSZNBJOUFOBODFPSrepairs as accidents may be caused. These operations must be
carried out by qualified personnel only.
t5IFPQFSBUPSJTNBJOUFOBODFGSFFCVUJUJTOFDFTTBSZUPDIFDLperiodically if the safety devices and the other components of
the automation system work properly. Wear and tear of some
components could cause dangers.
Waste disposal
Warning
All Benincá products are covered by insurance policy for any
possible damages to objects and persons caused by construction
faults under condition that the entire system be marked E and
only Benincá parts be used.
User’s handbook for the user
ITALIANO
BOB5024
A B
As indicated by the symbol shown, it is forbidden
to dispose this product as normal urban waste as
some parts might be harmful for environment and
human health, if they are disposed of incorrectly.
Therefore, the device should be disposed in special
collection platforms or given back to the reseller if
a new and similar device is purchased. An incorrect disposal of the
device will result in fines applied to the user, as provided for by
regulations in force.

1
9
5
13
3
11
7
2
10
6
414
11
12
12
8
Plastic cover
Release lever
Unblock. group
Blister
Motor
Upper cover
Gear
Worm screw
Lock with pin
Lower cover
Description
Limit stop
(Only BOB 524)
Locks
Wormscrew supp.
Encoder
(Only BOB 524E)
Cod.
9686630
9686631
9686632
9686633
9686643
9686635
9686636
9686637
9686638
9686639
9686640
9686641
9686642
9686516
n°
1
2
3
4
5
6
7
8
9
10
11
12
13
14
BOB5024 / BOB5024E
This manual suits for next models
2
Table of contents
Other Rotech Gate Opener manuals
Popular Gate Opener manuals by other brands

Aprimatic
Aprimatic ALZO EM 51 installation instructions

Calimet
Calimet CM9-975 quick start guide

Telcoma
Telcoma STEALTH Operation and Programming Instructions

C.C.E.
C.C.E. RADIO MOBILE TX EVO Assembly instructions

Leb Electronics
Leb Electronics STONE 230 instructions

Centurion
Centurion D2 Turbo user guide

Auto Ingress
Auto Ingress Rotary Arm installation manual

Portamatik
Portamatik ROSSO 60 User's and installer's manual

Benninca
Benninca RI.524K Operating instructions and spare parts catalogue

CAME
CAME A 3024 N installation manual

Motorisation+
Motorisation+ FULL24 Instructions and warnings for installation and use

DKS
DKS 9024-080 Installation and owner's guide