1
LRBS-FIX
RUD Ketten
Rieger & Dietz GmbH u. Co. KG
73428 Aalen
Tel. +49 7361 504-1370
Fax +49 7361 504-1460
[email protected]
www.rud.com
RUD-Art.-Nr.: 7901036-EN / 01.020
Lashing point
Load Ring weldable
> LRBS-FIX <
Safety instructions
This safety instruction/declaration has to be kept on le
for the whole lifetime of the product.
Translation of the original safety instruction
EN
Lashing point
Load Ring weldable
LRBS-FIX
Herstellererklärung
Hiermit erklären wir (unterstützt durch die Zertizie-
rung nach ISO 9001), dass die nachfolgend bezeich-
nete Ausrüstung aufgrund ihrer Konzipierung und
Bauart, sowie der von uns in Verkehr gebrachten
Ausführung, den einschlägigen grundlegenden Si-
cherheits- und Gesundheitsanforderungen der Eu-
ropäischen Union entspricht. Bei einer nicht mit uns
abgestimmten Änderung der Ausrüstung verliert diese
Erklärung ihre Gültigkeit. Weiterhin verliert diese
Erklärung ihre Gültigkeit, wenn die Ausrüstung nicht
entsprechend den in der Betriebsanleitung aufge-
zeigten bestimmungsmäßigen Fällen eingesetzt wird.
Hinweis: Beim Zurrpunkt angewendete harmonisierte
Normen DIN EN ISO 12100 T1 und T2 sowie in An-
lehnung an EN 1677.
Bezeichnung der Ausrüstung:
Zurrpunkt
Type: Load Ring Welding - LRBS-FIX
Herstellerzeichen:
Declaration of the manufacturer
We hereby declare (supported by ISO 9001 certi-
fication), that the following described equipment
based on the concept and design as well as the by
us manufactured type corresponds to the current
valid Health- and Safety Requirements of the EU.
This declarations becomes invalid in case of any
modi-cations not agreed upon with us. Furthermore
this declaration becomes invalid if the equipment is
not used according to this prescription.
Hint:Utilized harmonized standards for this Lashing
Point DIN EN 12 100 T1 and T2 as well as EN 1677..
Designation of the equipment:
Lashing point
Type: Load Ring Welding - LRBS-FIX
Manufacturer‘s sign:
2LRBS-FIX
Before initial usage of the RUD-LRBS-
FIX, please read carefully the safety
instructions. Make sure that you have
understood all subjected matters.
Non-observance can lead to serious per-
sonal injuries and material damage and
eliminates warranty.
1 Safety instructions
ATTENTION
Wrong positioned or damaged weld-on
lashing points as well as improper use can
lead to injuries of persons and damage at
property, when load falls down.
Please check all lashing points carefully
before every usage.
• The lashing points must not protrude in rest position
over the loading platform level.
• RUD-lashing points LRBS-FIX must only be used
by instructed and competent persons considering
BGR 500 (DGUV 100-500), and outside Germany
noticing the country specic statutory regulations.
2 Intended use of the LRBS-FIX
RUD-lashing points LRBS-FIX must only be used to
attach lashing means.
In general, lashing points must not be used for lifting!
RUD-lashing points must only be used in the hereby
specied case of operation.
3 Assembly- and instruction manual
3.1 General information
• Capability of temperature usage:
As of 07/2019: RUD-Lashing points LRBS-FIX are
suitable for the temperature range from -40°C up to
400°C.
Up to 07/2019: RUD-Lashing points LRBS-FIX are
suitable for the temperature range from -20°C up to
400°C.
For the use within the following temperature range,
the WLL must be reduced by the following factors:
-40°C / -20°C up to 200°C no reduction
200°C up to 300°C: by -10 % and
300°C up to 400°C: by -25 %
Temperatures exceeding 400°C are prohibited
In the unloaded state, LRBS-FIX anchor points
together with the load can be stress relieved by
heat treating (e.g. welded construction) once.
Temperature: < 600°C (one hour maximum).
After stress-relieving heat treatment (< 600°C),
however,the spring force is no longer usable.
• RUD-Lashing points LRBS-FIX must not be used
with aggressive chemicals such as acids, alkaline
solutions and their vapours.
• Please mark mounting position of lashing point with
a coloured contrast paint for better visibility.
• LRBS-FIX includes a protected positioned clam-
ping spring, inside the weld-on block. The spring
holds the weld-on blocks together with the ring and
creates at the same time a radial clamping function.
• RUD-lashing points LRBS-FIX are clearly marked
at the suspension ring with the permissible Lashing
capacity „LC“ in daN.
• LRBS-FIX will be delivered as a complete assem-
bled unit.
3.2 Hints for the assembly
Basically essential:
• The material construction to which the lashing
point will be attached should be of adequate
strength to withstand forces during lashing wit-
hout deformation. The weld-on material must be
suitable for welding and the contact areas must
be free from dirt, oil, colour, ect.
The material of the forged welding block is:
S355J2+N (1.0577+N (St52-3))
• The position of the lashing points must be carried
out in regard to the lashing means in such a way
that unintended movement like turning or ipping
of the load will be avoided.
• Determine number and position of the lashing
points at vehicles according to EN 12640 resp. DIN
75410 (for RoRo-transportation acc. to EN 29367),
unless the vehicles are not determined due to their
design and construction for transporting specic
goods with special requirements in regard of load
securing.
• Position lashing points as much as possible at the
outside width of the loading platform.
HINT
The lashing points must not protrude in rest
position over the loading platform level.
• Determine the necessary lashing capacity of each
lashing point acc. to EN 12195-1”Load securing
devices on road vehicles” - “Calculation of lashing
forces” and VDI 2700 ”Load securing of road ve-
hicles.”
• Check nally the correct assembly (see chapter 4,
Inspection criteria).
3.3 Hints for the welding
The welding should only be carried out according to
DIN EN ISO 9606-1 or AWS Standards by an autho-
rized and certied welder.
Verication of the used weld-on material must be
checked with the supplier of the welding electrodes.
3
LRBS-FIX
HINT
• Never weld at the quentched and
tempered ring!
• Weld all seams at the same temperature.
1. Check before initial appending of the LRBS-Fix, the
position of the weld-on blocks to each other, that
means the base area must be at the same level.
2. Append weld-on blocks.
3. Check function of the ring. The ring must be able
to pivot 180°. If necessary please correct.
4. Remove any welding mistakes and dirt at the root
weld before applying the cover weld seams.
5. Weld blocks on (HY-weld circumferential).
Choose type of weld seam and size according to
picture 2 and chart 2.
6. Please check by a competent person after welding
the ongoing usage of the weld-on lashing point
(see chapter 4, Inspection criteria)
HINT
By the position of the weld-seam (HY-weld
circumferential) the following requirements
will be observed: DIN 18800 steel con-
structions requires: at outdoor buildings or
when strong corrosion must be expected
weld seams must be carried out as conti-
nuous llet weld seams.
3.4 User instructions
• Check frequently and before each initial operation
the whole lashing point in regard of linger ability
as a lashing mean, regarding corrosion, wear, de-
formation etc. (see chapter 4, Inspection criteria).
ATTENTION
Wrong positioned or damaged weld-on
lashing points as well as improper use can
lead to injuries of persons and damage at
property, when load falls down.
Please check all lashing points carefully
before every usage.
• Please check carefully the wear indicator markings
of the weld-on lashing point (see picture 1):
Usage permitted:
no wear marks
visible
Use prohibited:
Replacement criteria rea-
ched. Material all the
way down to the
wear lenses has gone.
Pic 1: Wear indicators
• Please note that the lashing mean must be free
moveable in the LRBS-FIX. When lashing means
(f.e. lashing chain) are hinged or unhinged, no
pinching, shearing or joint spots must occure during
the handling.
• Avoid damage of lashing means resulting from
sharp edges.
• Lashing points must not be used for lifting loads.
3.5 Hints for regular inspection
In time periods complying to the need or usage, a
technical expert must control at least once a year the
appropriateness of the lashing point. This inspection
must also be done after each event of damage or
special incident.
4 Inspection criteria
Observe and control the following points before each
initial operation, in regular time intervals, after the as-
sembly and after special incidents.
• Completeness of the lashing point
• Complete and readable marking of Lashing Capa-
city as well as manufacturer sign
• Deformation at load bearing components like base
body and Ring.
• Mechanical damage, like strong notches, especially
in areas where tensile stress occurs.
• Reduction of cross-section due to wear >10 %
• Evidence of corrosion (pitting)
• Evidence of cracks
• Cracks or other damages at weld seam
Pic. 2: HY-weld seam
HY weld-seam
circumferntial
4LRBS-FIX
Chart 3: Dimensioning LRBS-FIX complete Subject to technical alterations
Chart 1: Welding procedure + Welding ller metals
Chart 2: Weld seam (weld-on block)
HINT
Please note the cor-
responding user hint
in regard of the wel-
ding ller materials
and the drying re-
quirements*.
Pic 4: Dimensioning LRBS-FIX complete Pic. 5: Dimensioning Lashing Ring
Pic 3: Lashing Ring is
integrated in the design
Type
LRBS-FIX compl.
LC
[daN]
A
[mm]
B
[mm]
C
[mm]
D
[mm]
E
[mm]
F
[mm]
T
[mm]
weight
[kg/pc.]
Ref. no
LRBS-FIX 8000 8000 60 14 39 48 132 69 74 0.93 7999303
LRBS-FIX 13400 13400 88 20 50 60 167 91 97 2.2 7999304
LRBS-FIX 20000 20000 100 22 60 65 191 100 108 3.7 7999305
LRBS-FIX 32000 32000 130 30 72 90 267 134 140 8.0 7999306
Type
Lashing Ring
LC
[daN]
A
[mm]
B
[mm]
C
[mm]
D
[mm]
E
[mm]
F
[mm]
G
[mm]
T
[mm]
O
[mm]
Q
[mm]
weight
[kg/pc.]
Ref. no
Lashing Ring 8000 8000 107 14 69 48 17 18 76 63.5 19+0.5 77+1 0.38 7902251
Lashing Ring 13400 13400 134 20 91 60 23 23 100 82.5 25+0.5 101+1 0.96 7902252
Lashing Ring 20000 20000 152 22 100 65 28 29 105 92 30+0.5 106+1 1.46 7902331
Chart 4: Dimensioning LRBS-FIX Lashing Ring Subject to technical alterations
Europe, USA, Asia, Australia, Africa
Baustähle, niedrig legierte Stähle EN 10025,
Mild steels, low alloyed steel EN 10025
MIG / MAG (135)
Gas shilded wire welding
(135)
DIN EN ISO 14341: G4Si1 (G3Si1)
Z.B. PEGO G4Si1
E-Hand Gleichstrom (111, =)
Stick Electrode direct current
DIN EN ISO 2560-A: E 42 6 B 3 2 H10
DIN EN ISO 2560-A: E 38 2 B 1 2 H10
z.B. PEGO B Spezial*/
PEGO BR Spezial*
E-Hand (Wechselstrom 111, ~)
Stick Electrode alternating
current
DIN EN ISO 2560-A: E 38 2 RB 1 2
DIN EN ISO 2560-A: E 42 0 RC 1 1
z.B. PEGO RC 3 / PEGO RR B 7
Alternativ:
DIN EN ISO 3581: E 23 12 2 L R 3 2
z.B. PEGO 309 MoL
WIG (141)
TIG Tungsten arc welding
DIN EN ISO 636-A: W 3 Si 1 (W2 Si 1)
DIN EN ISO 636-A: W 2 Ni 2
z.B. PEGO WSG 2 / PEGO WSG2Ni2
Type Size Length Volume
LRBS-FIX 8000 HY 3 2 x 154 mm approx. 1.4 cm³
LRBS-FIX 13400 HY 5 2 x 214 mm approx. 5.35 cm³
LRBS-FIX 20000 HY 6 2 x 252 mm approx. 9 cm³
LRBS-FIX 32000 HY 9 2 x 341 mm approx. 27 cm³

This manual suits for next models

4

Other RUD Welding Accessories manuals

RUD PowerPoint WPP Series User manual

RUD

RUD PowerPoint WPP Series User manual

RUD VRBS-FIX Series User manual

RUD

RUD VRBS-FIX Series User manual

RUD LPW 300 User manual

RUD

RUD LPW 300 User manual

Popular Welding Accessories manuals by other brands

STAMOS SWB01 user manual

STAMOS

STAMOS SWB01 user manual

STAMOS SWP02 user manual

STAMOS

STAMOS SWP02 user manual

Tool it FLIP FLAP manual

Tool it

Tool it FLIP FLAP manual

Kemppi MTP 350 operating manual

Kemppi

Kemppi MTP 350 operating manual

Bohler voestalpine URANOS 1500 instruction manual

Bohler

Bohler voestalpine URANOS 1500 instruction manual

Miller Electric OM-1102 owner's manual

Miller Electric

Miller Electric OM-1102 owner's manual

Parkside 85053 Operation and safety notes

Parkside

Parkside 85053 Operation and safety notes

Clarke GWH4 Operation & maintenance instructions

Clarke

Clarke GWH4 Operation & maintenance instructions

EWM Trolly 55-6 DF operating instructions

EWM

EWM Trolly 55-6 DF operating instructions

Parkside PSHP 1 A1 Operation and safety notes

Parkside

Parkside PSHP 1 A1 Operation and safety notes

3M Speedglas 9100 manual

3M

3M Speedglas 9100 manual

OXO MVP8-RC SERIES owner's manual

OXO

OXO MVP8-RC SERIES owner's manual

Murex US-W205M datasheet

Murex

Murex US-W205M datasheet

Senci SC-1250 user guide

Senci

Senci SC-1250 user guide

Lincoln Electric GRAPHICS MAY VARY Operator's manual

Lincoln Electric

Lincoln Electric GRAPHICS MAY VARY Operator's manual

EINHELL 9-13 Original operating instructions

EINHELL

EINHELL 9-13 Original operating instructions

Speedglas 100 User instructions

Speedglas

Speedglas 100 User instructions

GYS Junon LCD 5/9 user manual

GYS

GYS Junon LCD 5/9 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.