Safety Technology International STI-6400 User manual

1. Make sure key switch is in the OFF
position.
2. Remove cover from base unit by
applying pressure to the key barrel.
Ensure that the tamper screw located
on the bottom right hand side is removed
by using the tamperproof tool provided.
3. Set switches, on circuit board, to desired
alarm settings (figure 4 see over).
4. Mount base unit on or next to door using
the 2 fixings provided. (See Dia. A for
recommendation*). Reed switch mounting
locations can be moved to the four positions
shown in Dia. A. If mounted next to door,
route reed switch wire through knockout in
bottom of housing as shown in figure 2.
5. Mount magnet on door frame (or door if
unit is mounted next to door) using screws
provided. When mounting on metal doors
or door frames, use plastic spacer provided.
Reed switch and magnet must be within
13mm/1/2" when door is closed. Please refer
to figures 5, 6 and 7 for other mounting options.
6. To fix the cover to the base unit, hooks
can be found on the inside top edge of the
cover. Insert the hooks into the slots provided
on the edge of the base unit (see Dia. B) and
snap the cover down until it clicks into place.
Using the tamperproof tool provided insert
and tighten the screw to secure the cover to
the base (see Dia. C).
7. REMOVING THE COVER FROM THE BASE
Remove the tamper screw located on the bottom
right hand side with the tamperproof tool provided.
Apply pressure to the key barrel. Keep the
tamperproof tool safe for future servicing and
battery change.
EXIT STOPPER
A completely self-contained security system that provides a highly effective, extremely versatile and
inexpensive way to help prevent unauthorised use of fire/emergency doors. The EXIT STOPPER is
supplied with an installation kit and 9v alkaline battery. It also incorporates a key override facility for
authorised use.
SCREW
6 x 1 1/4 in.
(2) PROVIDED
SHOWN
BOTTOM SURFACE AS
WIRES THROUGH NOTCH ON
AND ROUTE REED SWITCH
REMOVE FRONT COVER
(USED AS NECESSARY)
SPACERS
NOTE: 2 SPACERS UNDER BOTH
MAGNET AND REED SWITCH
MUST BE USED ON STEEL DOORS
VIEW SHOWING MAGNET INSTALLATION
NB: FITTING UNIT AWAY FROM DOOR (OPTIONAL)
MAGNET
13mm [1/2 in.]
MAXIMUM GAP
FIGURE 2
Need help? Call our Technical Support Team on +44 (0)1527 520 999
INSTALLATION DATA FOR THE STI-6400 & STI-6400/WIR
Housing 3mm 1/8" polycarbonate
Power Source 9 VDC Alkaline
Sounder Output 95 dB - low/105 dB - high
Relay Output 9 VDC, 40mA
Dimensions 136mm/5.35" h x 136mm/5.35" wx 50mm/1.97" d
Standby Current 10uA
Alarm Current 200mA
SPECIFICATIONS
STI-6400 Exit Stopper
STI-6402 Exit Stopper Double Door
STI-6400/RK Remote Kit
STI-6400/RS Remote Sounder
PART No.
EXIT STOPPER PART NUMBERS
PRE INSTALLATION CHECKLIST
IMPORTANT NOTICE: If you have purchased a STI-6400/WIR model, before installation you will need
to ‘learn’ the transmitter to the 8 channel receiver. Please refer to the Quick Setup Guide. Once‘learned’,
follow steps 1-7 opposite.
DO YOU WANT HIGH OR LOW SOUNDER OUTPUT?
The Exit Stopper is factory set for HIGH sounder output (105 dB). To change the unit to a LOW output
(95 dB), locate JP2 and move to the OFF position.
DO YOU WANT THE EXIT STOPPER TO ALARM IMMEDIATELY?
The Exit Stopper is factory set to arm immediately after the key is turned to the ON position. You can
change this to a 15 second arming delay. This feature allows an authorised key holder to turn the unit
on and then exit through the door before the unit arms. To set a 15 second arming delay move jumper
JP7 to the OFF position.
DO YOU WANT THE EXIT STOPPER TO ACTIVATE IMMEDIATELY THE DOOR IS OPENED?
The Exit Stopper is factory set to activate immediately the protected door is opened. The unit can be
set for a 15 second delay. This would allow an authorised key holder to open the door and turn the Exit
Stopper off before it activates. To set to a 15 second activation delay move the jumper to JP5 to the ON
position.
SOUNDER OUTPUT OPTIONS
The Exit Stopper is factory set to sound for 30 seconds once activated. There are three other settings,
180 seconds, continuous and 5 beeps.
STI F021
STI CO23/A
STI BAT1
STI L6400
ACCESSORIES
DIA. B
PART No.
PC BOARD
REED SWITCH
REED SWITCH MOUNTING
KEY
(2) PROVIDED
OUTER COVER
NOTE: TO SELECT ALARM OPTIONS,
REMOVE OUTER COVER AND FOLLOWING
THE SWITCH SETTINGS CHART, SHOWN ON
REVERSE SIDE, CHOOSE THE ALARM
OPTIONS SUITABLE FOR EACH INSTALLATION.
SCREW #8 x 1 in.
(2) PROVIDED
USING BACKPLATE AS
TEMPLATE MARK AND DRILL
(2) 4.7 mm [3/16 in] DIA. HOLES
RAWLPLUG
(2) PROVIDED
SHOWN IN FACTORY
INSTALLED POSITION
9 VOLT
ALKALINE
BATTERY
KEYSWITCH
4FIXING HOLES
DIA. A
SLOT
PEGS. (4 OPTIONALPOSITIONS)
SLOT
SCREW
TAMPER-PROOF
(1) PROVIDED
TAMPER
PROOF TOOL
(1) PROVIDED
DIA. C
FIGURE 1
*
*
*recommendation
for the fixings
ID6400-6400WIR · Revised 10/16-001 · Printed in England
SLOT
HOOK
VIEW SHOWING HOW TO FIX THE COVER TO THE BASE
FIGURE 3
Need help? Call our Technical Support Team on +44 (0)1527 520 999
Safety Technology International
Taylor House, 34 Sherwood Road, Bromsgrove
Worcestershire, B60 3DR, England
Telephone: +44 (0) 1527 520 999
Fax: +44 (0) 1527 501 999
E mail: inf[email protected] Web Site: www.sti-europe.com
Emergency Exit Warning Sign
9 V Battery
Spare Keys
Tamperproof Tool
DESCRIPTION DESCRIPTION
VIEW OF CIRCUIT BOARD
ID6400-6400WIR· Revised 10/16-001 · Printed in England
JP5
JP2
JP4
JP3
JP7
ALARM
DURATION
SWITCH
ALARM VOLUME SWITCH
ARMING SWITCH
(ON)
(ON)
(OFF)
(OFF)
(OFF)
IMMEDIATE ARMING ACTIVATION
High Volume* (105 dB)
Low Volume (95 dB)
Immediate Arming* ON*
15 Second Arming Delay OFF
Immediate Arming Activation* OFF*
15 Second Activation Delay ON
30 Second Alarm Duration* OFF*
180 Second Alarm Duration OFF
Continuous Alarm Duration ON
Door Prop Mode (5 Beeps)
JP2 JP3 JP4 JP5 JP7
*Factory Settings
NOTE: Slide black lever to desired ON/OFF position as labelled on circuit board
FEATURE
ON*
OFF
OFF*
ON
OFF
ON ON
TERMINAL BLOCK
NC COM NO GD V+ RS1 RS2 KEYSW
TERMINAL BLOCK WIRING CONNECTIONS
FORM C
DRY
CONTACTS
REMOTE
POWER
INPUT
9-24 VDC
REED
SWITCH
TERMINALS
KEY SWITCH
TERMINALS
FIGURE 4
(FACTORY DEFAULT SETTINGS)
CIRCUIT BOARD SET-UP MOUNTING OPTIONS
FIGURE 7
TYPICAL DOUBLE DOOR INSTALLATION
STI-6402
FIGURE 6
FIGURE 5
DOOR
DOOR STOP
JAM
MAGNET
6400 UNIT
MAGNET MUST BE
INSTALLED OPPOSITE
RAISED RIB ON OUTER COVER.
SPACERS (USE
AS NECESSARY)
RAWL PLUG
(2) PROVIDED
TYPICAL FLUSH MOUNT DOOR JAM
INSTALLATION
DOOR
SWING
NOTE: 2 SPACERS MUST BE
USED ON STEEL DOORS
SCREW
6 x 1 1/4 in.
(2) PROVIDED
MAGNET
6400 UNIT
DOOR STOP
SWING
DOOR
TYPICAL RECESSED MOUNT DOOR JAM
INSTALLATION
MAGNET ASM.
19 mm [3/4 in.]
MAXIMUM GAP
(SEE FASTING
ATTACHMENTS
ABOVE )
Need help? Call our Technical Support Team on +44 (0)1527 520 999Need help? Call our Technical Support Team on +44 (0)1527 520 999

This manual suits for next models

1

Other Safety Technology International Safety Equipment manuals

Safety Technology International EM243608A1 User manual

Safety Technology International

Safety Technology International EM243608A1 User manual

Safety Technology International STI-13000 Series Quick start guide

Safety Technology International

Safety Technology International STI-13000 Series Quick start guide

Popular Safety Equipment manuals by other brands

Guardian 15220 instruction manual

Guardian

Guardian 15220 instruction manual

DELTA PLUS MACH SPIRIT manual

DELTA PLUS

DELTA PLUS MACH SPIRIT manual

Protekt TROLLEY ST012 quick start guide

Protekt

Protekt TROLLEY ST012 quick start guide

OEZ OD-FH000-Z1 Instructions for use

OEZ

OEZ OD-FH000-Z1 Instructions for use

3M Peltor X Series manual

3M

3M Peltor X Series manual

CMC HELITACK HOTSEAT manual

CMC

CMC HELITACK HOTSEAT manual

SKYLOTEC SIRIUS Instructions for use

SKYLOTEC

SKYLOTEC SIRIUS Instructions for use

Petzl RAD LINE manual

Petzl

Petzl RAD LINE manual

BUCKINGHAM MFG 488W Instructions & warnings

BUCKINGHAM MFG

BUCKINGHAM MFG 488W Instructions & warnings

IN&MOTION IN&BOX user manual

IN&MOTION

IN&MOTION IN&BOX user manual

Latchways R20 User instructions

Latchways

Latchways R20 User instructions

Scott Safety FH3 Operating and maintenance instructions

Scott Safety

Scott Safety FH3 Operating and maintenance instructions

Beta 7042LCD Instructions for use

Beta

Beta 7042LCD Instructions for use

Knauf SHAFTLINER MOULDSTOP Installation

Knauf

Knauf SHAFTLINER MOULDSTOP Installation

Daniamant Dan WL3-2 Installation and maintenance instructions

Daniamant

Daniamant Dan WL3-2 Installation and maintenance instructions

Camp Safety GIANT manual

Camp Safety

Camp Safety GIANT manual

Zero HTP1679 instruction manual

Zero

Zero HTP1679 instruction manual

Silverline 254301 manual

Silverline

Silverline 254301 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.