The CT100 is apractical surface mounted mechanical thermostat.
This thermostat will allow the user tocontrol the temperature of
Domestic Hot Water Cylinders (uninsulated and foam lagged).
This unit comes complete with awire strap which enables the CT100 to
be used alsoas apipe thermostat.
This unit can be used toswitch acirculating pump, boiler or most
common motorised zone valves.
Wiring
Diagram
Specification
Dimension (mm)
A B C
105 50 45
Voltage Rating : 230 AC 50Hz
Switch Rating : 16Aresistive
: 4A inductive
Switch Type : Single pole, double throw (SPDT)
Temperature Setting Range : 40 to80oC
Ambient Temperature : 0 to 55oC
Agency Approval : CE
FIXINGS FOR BOTH CYLINDER/PIPE THERMOSTAT ARE INCLUDED WITHIN THE BOX.
Internal
Diagram
A
B
C
Once the CT100 has been
situated in the correct location
and connected, simply turn
the dial tothe desired setting
making sure the temperature
required lines up with the
arrow on the main body of the
CT100. Fixings for both
Cylinder/Pipe Thermostat are
included within the box.
Setting The
Temperature
Thank you for purchasing this Salus product -if installing for someone
else, please ensure that the instructions are handed to the householder.
Warning- Please read this manual prior toinstallation or use.
ShockHazard
This unit must be installed by acompetent person, in accordance with
BS 7671 (the IEE Wiring Regulations), or other relevant national
regulations and codes of good practise.
Alwaysisolate the AC Mains supply before removing the unit
from the Industry Standard Back Plate.
Terminals C and 1 make
on temperature rise.
Terminals C and 2 make
on temperature fail.
CT100
THERMOSTAT
C 21
+C
º