3-4 Samsung Electronics
3-2-5 Panel key operation
Key operational function Key Type
ON/OFF Operation start and stop TACT
*First ON = operation start, second ON = operation stop
*Continuous operation is not available.
Mode Operation mode change (in case of model option heat pump) TACT
*at every ON
- Selected as "COOL –> HEAT –> FAN". (Default=COOL)
*If operation is OFF, it is considered as an invalid key.
*Continuous operation is not available.
Fan speed Indoor fan speed setting.
*At every ON -> selected as "HIGH -> LOW -> HIGH".
*If operation is OFF, it is considered as an invalid key.
*Continuous operation is not available.
Temp. Currently displayed set temperature circulation (in case of option -> ˚C) TACT
*At every pressing, the set temperature is changed by 1˚C (cooling operation)
(24˚C -> 25˚C -> 26˚C -> 27˚C ---> 30˚C -> 18˚C -> 19˚C -> 20˚C ---> 24˚C).
*At every pressing, the set temperature is changed by 1˚C (heating operation)
(24˚C -> 25˚C -> 26˚C -> 27˚C ---> 30˚C -> 16˚C -> 17˚C -> 18˚C ---> 24˚C).
*Single and continuous operation is available.
*In case of the set temperature of 30˚C, when the "increase" key is pressed by
remocon, temperature does not increase any more and waring, sound is
generated.(cooling, heating operation) --> The panel key is circulated continuously.
*If operation is OFF, it is considered as an invalid key.
*In case of fan speed operation, it is considered as an invalid key.
Currently displayed set temperature circulation (in case of option --> ˚F)
*At every pressing, the set temperature is changed by 1˚F (cooling operation)
(75˚F -> 76˚F -> 77˚F ---> 86˚F -> 64˚F -> 65˚F -> 66˚F -> 67˚F ---> 75˚F).
*At every pressing, the set temperature is changed by 1˚F (heating operation)
(75˚F -> 76˚F -> 77˚F ---> 86˚F -> 61˚F -> 62˚F -> 63˚F -> 64˚F---> 75˚F).
*Single and continuous operation is available.
*In case of the set temperature of 86˚F, when the "increase" key is pressed by
remocon, temperature does not increase any more and warning, sound is
generated.(cooling, heating operation) --> The panel key is circulated continuously.
*If operation is OFF or fan speed, it is considered as an invalid key.
Air swing Left and right swing motor operation and stop. TACT
*Once ON = Left and right swing motor operation, Another ON = Left and right
swing motor stop.
*In case of cool blowing inhibition, it is considered as an invalid key.
(only in fan motor OFF range)
*In case of defrosting operation, it is considered as an invalid key.
(only in fan motor OFF range)
*Continuous operation is not available.
*In case of operation stop, when the fan motor is turned off it is considered
as an invalid key.
*In case of deicing operation, the left and right swing motor does not operate.
(it operates when the fan motor is being operated)
Timer Time increase by the convenient reserve (OFF TIMER) time control key. TACT
*At every pressing the time is increased by 1 hour.
(--> 01 -> 02 -> 03 -> 04 -> 05 ---> 18 -> 19 -> 20 -> 21 -> 24 -> --)
*"--" means that the convenient reserve time is not set yet.
(convenient reserve cancelled)
*Single and continuous operation is available.
*If operation is OFF, it is considered as an invalid key.
Key discription
Key name