16 ETHM-1 Plus SATEL
Code – the code which is to be used for authorization when executing commands contained
in the macro command. The code must have an appropriate authority level for execution of
such commands to be possible. The code is presented as a string of asterisks.
If the code turns out to be incorrect when running macro commands (e.g. it was
changed in the meantime), the user will be able to enter the correct code. It will be
automatically saved to the device memory (to replace the invalid code).
Authorization required – if this option is enabled, the macro command will only be run after
user authorization by means of code. The code entered in the “Code” field will be ignored.
Disabl. if armed – if this option is enabled, the macro command will not be available, if any
of the partitions managed by the virtual keypad is armed.
Autoexecute – if this option is enabled and there is only one macro command in the group,
the macro command will be run immediately on tapping the macro key (if the
AUTHORIZATION REQUIREDoption is enabled, user authorization by means of code will be
required).
Commands list – commands assigned to the currently highlighted macro command. The
and buttons allow you to change the order of commands (moving the
highlighted command up and down).
Add – click on the button to add to the list a new command, selected in the “Command” field.
Change – click on the button to save the changes to the command parameters which were
made after adding the command to the list (otherwise, the changes made will not be
saved).
Delete – click on the button to remove the highlighted command from the list.
Command – function executed by the control panel, which can be assigned to the macro
command. To display the list of all available functions, click on the button. Depending
on which function you have selected:
Arming – highlight the partitions which are to be armed (double-click on the field
designated by the partition number) and define the arming mode (next clicks on the field
designated by the partition number; the digit inside the field has the following meaning:
0 - fully armed; 1 – fully armed+bypasses; 2 – armed without interior; 3 - armed without
interior and without entry delay).
Disarming – highlight the partitions which are to be disarmed (double-click on the field
designated by the partition number).
Alarm clearing – highlight the partitions in which alarm is to be cleared (double-click on
the field designated by the partition number).
Bypass zones – highlight the zones which are to be inhibited (double-click on the field
designated by the zone number).
Unbypass zones – highlight the zones which are to be unbypassed (double-click on the
field designated by the zone number).
Outputs ON – highlight the outputs which are to be activated (double-click on the field
designated by the output number).
Outputs OFF – highlight the outputs which are to be deactivated (double-click on the field
designated by the output number).
Change outputs state – highlight the outputs whose status is to be changed (double-click
on the field designated by the output number).
KNX telegram – program the following parameters of KNX telegram:
INT-KNX module – INT-KNX module which is to send the telegram.
Group address – the group address which will be inserted in the telegram.