4 SPL-2010 SATEL
electronics board.
tamper element with mounting hole.
water drain holes (do not plug).
3. Installation and start-up
Power down the control panel before connecting the siren to the control panel.
The siren must be installed on the wall, high above the floor, at a hard to access location, so
as to minimize the risk of tampering. Leave a space above the siren –at least 4.5 cm
between the siren and the ceiling or other object. Otherwise, it will be impossible to replace
the cover.
1. Remove the cover locking screw.
2. Lift up the enclosure cover and remove it (Fig. 4).
3. Pull aside the mounting catches of the inner metal cover and remove it.
4. Place the enclosure base on the wall and mark the location of mounting holes (Fig. 3).
Remember to take into account the mounting hole for tamper protection.
5. Drill the holes for wall plugs (anchors).
6. Run the wires through the opening in the enclosure base (Fig. 3).
7. Use wall plugs (anchors) and screws to secure the enclosure base to the wall. Remember
about the mounting hole for tamper protection. Select appropriate wall plugs based on the
type of the mounting surface (different for concrete or brick wall, different for plaster wall,
etc.).
8. Connect the siren terminals to the control panel terminals using wires.
Some alarm control panels may require that a resistor R (approx. 1 kΩ) be connected
between the +SA- terminals in the siren (Fig. 3). Otherwise, the siren may produce
a buzzing sound when inactive (if there is no buzzing, the resistor is not required).
9. Use jumpers to select the tone (Fig. 2).
10.Replace the inner metal cover.
11.Replace the siren cover and lock it with the screw.
12.Power on the control panel.