Instruction Manual
Digital Thermometer Model PC-3300
(for Refrigerator)
Thank you for purchasing the PC-3300 Digital Thermometer.
- This product is designed to measure inside temperature of a refrigerator.
Do not use it for other purposes.
- Read this manual thoroughly before using the PC-3300. Keep the manual in
a safe place for future reference whenever necessary.
Names and Functions of Components
Front View Rear View
 Two-Ways of Hook Usage
How to use
Please have the unit adapt to the measurement environment for at least
30 minutes before using.
1. Displaying the Current Temperature
 When the external probe is not connected, the temperature around the
unit is displayed.
 When the external connected is connected, the unit automatically
displays the temperature reading detected by the external sensor.
2. Displaying the MAX/MIN Temperature
The MAX & MIN temperature readings are displayed all the time.
The MAX/MIN memory starts by following situations.
 Load or replace the battery
 Press the RESET key (Previous MAX/MIN memory will be deleted.)
Note: The MAX/MIN memory is kept even if the external probe is removed
or connected. To clear the previous data, press the RESET key.
(1) Use of internal sensor
The main unit can be used in a refrigerator that its inside temperature
is -5˚C or higher. Do not use the main unit in lower than -5˚C state.
Secure the protective cap into the sensor jack at that time.
(2) Use of external probe
By using the external probe, it is possible to check
the inside temperature of a refrigerator from
outside.
Put the external probe inside through the gap of the
refrigerator door hinge as shown in the picture.
Note: The probe cord is delicately made. Carefully
handle it not to break the wire.
Max. Temperature
Current Temperature
Min. Temperature
Min/Max RESET ke
y
For mount For stand
Cord (3m)
External sensor
Cord Attachment <example>
Probe
j
ack
Protective Cap
(Fasten the cap to the probe jack when not in use)
Hook
Battery Lid
Error Messages
When the temperature is out of measuring range, the display will show
“HH” or “LL”. In that case, take the probe away from the measuring area
and stop the measurement for one minute, then press the RESET key to
return normal s.
3. Replacing Battery
When the ‘˚C’ mark on the display blinks, it is time to replace the battery.
(1) Use a coin to open the battery lid and remove the exhausted battery.
(2) Wait for about 5 minutes. Do not replace it with a new one immediately.
(3) Install a new battery (LR44) with the “+” mark on the battery facing up.
(4) Close and secure the battery lid.
Note: If the display does not return to normal, repeat the procedure (1) to (4),
but be sure to leave it 5 minutes or more after removing the battery.
4. Cautions
 Avoid direct contact with water.
 Do not insert the external probe in water.
 Do not bend or forcibly pull the cord.
 Do not stick the external probe into any solid material.
 Never disassemble or alter the unit to avoid malfunctions.
 Do not dispose used batteries in fire.
 For environmental conservation, dispose used batteries in compliance with
local rules and regulations.
 Do not clean the thermometer with alcohol, thinner or any other solvents.
When the thermometer is stained, clean with a soft and dry cloth or a clean
cloth moistened with neutral detergent water.
 Do not use the thermometer out of the temperature range.
5. Specifications
Product : Digital Thermometer
Model : PC-3300
Cat. No. : No. 1740-00
Main unit
Measuring range : -50 to 70˚C (use of external probe)
: - 5 to 50˚C (use of internal sensor)
Accuracy : ±1˚C at 0 to 40˚C
:±2˚C at other than above
Sampling time : every 1 min.
Operating conditions : -5 to 50C, 10 to 85%rh (no condensing)
Power requirements : 1.5VDC (one LR44 button battery)
Battery life : about 1 year continuous
Dimensions : 67 (W) 65 (H) 20 (D) mm
Materials : ABS resin
External probe
Sensing element : Thermistor
Heat-resistance temp. of cord : 50˚C
Waterproof property : JISC 0920 (equivalent to IPX4)
The sensor cannot be used in water
Cord length : about 3 m
Weight : about 50 g (with battery)
Standard accessories : external probe, cord attachment,
one LR44 button battery
3-4, Kanda-kajicho, Chiyoda-ku, Tokyo 101-0045 Japan
URL: http://www.sksato.co.jp/english/
S.05

Other SATO Thermometer manuals

SATO SK-8920 User manual

SATO

SATO SK-8920 User manual

SATO PC-3710 User manual

SATO

SATO PC-3710 User manual

SATO PC-9215II User manual

SATO

SATO PC-9215II User manual

SATO SK-810PT User manual

SATO

SATO SK-810PT User manual

SATO SK-8300 User manual

SATO

SATO SK-8300 User manual

SATO MIN-MAX II User manual

SATO

SATO MIN-MAX II User manual

SATO SK-8100 Series User manual

SATO

SATO SK-8100 Series User manual

SATO PC-3310 User manual

SATO

SATO PC-3310 User manual

SATO SK-270WP User manual

SATO

SATO SK-270WP User manual

SATO SK-270WP-K User manual

SATO

SATO SK-270WP-K User manual

Popular Thermometer manuals by other brands

Center 520 instruction manual

Center

Center 520 instruction manual

Hanna Instruments Pronto Plus HI99551 Series user manual

Hanna Instruments

Hanna Instruments Pronto Plus HI99551 Series user manual

Rossmax TG120 instruction manual

Rossmax

Rossmax TG120 instruction manual

Mastech MS6531ABC user manual

Mastech

Mastech MS6531ABC user manual

Zorpro Zortemp 1000 instruction manual

Zorpro

Zorpro Zortemp 1000 instruction manual

PCE Instruments PCE-IR 6 user manual

PCE Instruments

PCE Instruments PCE-IR 6 user manual

Ambient Weather WH31P user manual

Ambient Weather

Ambient Weather WH31P user manual

Optex THERMO-HUNTER  VF-3000 instruction manual

Optex

Optex THERMO-HUNTER VF-3000 instruction manual

DeWalt DCT414 instruction manual

DeWalt

DeWalt DCT414 instruction manual

Traceable 4126 instructions

Traceable

Traceable 4126 instructions

GRx Diagnostics TD-1241 owner's manual

GRx Diagnostics

GRx Diagnostics TD-1241 owner's manual

Braun BFH175 manual

Braun

Braun BFH175 manual

sauermann Si-TT3 user manual

sauermann

sauermann Si-TT3 user manual

MABIS ForeTEMP 18-575-000 instruction manual

MABIS

MABIS ForeTEMP 18-575-000 instruction manual

Oregon Scientific SL101 quick start guide

Oregon Scientific

Oregon Scientific SL101 quick start guide

AHB Solutions 320000390 manual

AHB Solutions

AHB Solutions 320000390 manual

TysonBio NC100 user manual

TysonBio

TysonBio NC100 user manual

Gefu 21840 Instructions for use

Gefu

Gefu 21840 Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.