Warning
This is a Class 1 product and must be earthed.
Please read these instructions carefully before
commencing any work
This unit must be fitted by a competent and
qualified electrician.
Install in accordance with the IEE Wiring regulations
and current Building Regulations.
Check the pack and make sure you have all the parts listed.
To prevent electrocution switch off at the mains supply
before installing or maintaining this fitting. Ensure other
persons cannot restore the electrical supply without your
knowledge. If you are in any doubt, please consult a
qualified electrician.
If replacing an existing fitting, make a careful note of the
connections.
The entire unit gets hot whilst on for a period of time.
This product is not suitable for location in or near a marine
environment.
Waste electrical products should not be disposed of with
household waste. Please recycle where facilities exist. Check
with your local authority or retailer for recycling advice.
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Layout
Plan the desired layout of these fittings carefully, ensuring the
cables will reach the distances between fittings.
Avoid locating any cables in positions that would cause a hazard.
Position cables and outdoor rated junction boxes (not supplied)
away from areas where they may be at risk from being cut,
trapped or damaged.
This product is supplied with 0.8 metres of H05RN-F outdoor
grade rubber sheathed cable ready for connection to an
approved, outdoor rated terminal block which is not supplied
and must be obtained.
The mains supply cable must have a minimum cross section
area of 1.0mm2.
The external flexible cable or cord of this luminaire cannot be
replaced. If the cord is damaged, the luminaire must be
destroyed.
Cables must be protected using suitable conduit or plastic
trunking.
This is a floodlight product, and therefore should be positioned
where it will not cause a glare hazard.
• Hold the product in position and mark the location of the
fixing holes. The bracket can be removed from the
fitting for ease of installation.
• Fix the bracket to the wall using the expansion bolt
(not supplied). Take care to avoid damaging any concealed
wiring and pipes. The correct fixings should be used for
brick or cavity walls.
Adjust the
desired angle
(both side)
• Using the Allen key (not supplied), loosen the bolts on the
both side, and adjust the fitting to the desired angel.
• Wire as detailed wiring.
• Adjust the sensor if needed according to your preferred.
• Turn on your power switch. your light is ready for use.
See wiring diagram
Using suitable IP
rated terminal block
(not supplied)
Brown Y./G. Blue
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the sensor lamp could not work!
If the lamp is more than 60W, the distance between lamp and sensor should be 60cm at least.
Installation
PIR sensor adjustable
Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully
note the position of each set of wires.
Note that the switch is turned off before installation.
Do not mount ceiling/wall fitting onto damp surfaces such as newly painted or plastered areas as this may
cause discolouration of the finish.
Adjustable up to 10 metres
PIR Adjustment
1.8- 2.5Metres
2M 6M
10M
appro. 120º
• The unit must be installed in a vertical position, and fitted 1.8-2.5m above the ground
• Turning the SENS dial anticlockwise will decrease the detection range (2m-10m)
• Turning the TIME dial anticlockwise will decrease the hold time (10 seconds-7minutes)
• Turning the LUX dial anticlockwise will restrict activation to lower light conditions (<10-2000lux)
Detection Range: 120º
Working Temperature: -20~+40ºC
Working Humidity: <93%RH
Installation Height: 1.8-2.5m
Detection Motion Speed: 0.6-1.5m/s
Detection Distance: Max. 2-10m (<24ºC)
Power Source: 220-240V~
Power Frequency: 50Hz
Ambient Light: <10-2000LUX (adjustable)
Time-Delay: Min.10sec±3sec
Max.7min±2min
Rated Load: 100W + LED
Power Consumption: approx 0.5W
Manual override mode:
When first switched on, the PIR sensor will goes into “warms up” self test:
1) If there are no action, the PIR sensor “warms up” self test for approx 30 seconds and then goes into AUTO mode;
2) If switch the power OFF and ON twice within 3 seconds ((OFF-ON-OFF-ON), the PIR sensor will switch to MANUAL mode.
If switch the power OFF and ON twice within 3
seconds (OFF-ON-OFF-ON), the PIR sensor will
switch to MANUAL mode.
In AUTO mode, the light is with PIR function:
In MANUAL mode, the light will remain ON permanently,
without the PIR function:
1) If switch the power OFF more than 10 seconds,
the PIR sensor will return to 'warm up' self test
process.
POWER ON AUTO MODE
MANUAL MODE
“warms up” self test
Power OFF
more than 10 seconds
Power OFF
more than 10 seconds
(OFF-ON-OFF-ON)
Switch the power OFF/ ON
twice within 3 seconds
with PIR function
without PIR function
No action
for 30 seconds
The PIR sensor has a manual override function which can be operated by taking the following steps:
108672(10W)
108673(20W)
108674(30W)
108675(50W)
Product Code Weight Dimensions
Max.
Projected Area
0.277kg Proj: 54.1mm H: 168.6mm W: 97.4mm
Proj: 54.1mm H: 189.9mm W: 121.3mm
Proj: 55.2mm H: 227.5mm W: 154mm
Proj: 57mm H: 262.6mm W: 182.3mm
0.0087m²
0.350kg 0.0125m²
0.526kg 0.0216m²
0.699kg 0.0320m²
W
H
Proj