manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Saxby Lighting
  6. •
  7. Floodlight
  8. •
  9. Saxby Lighting Magma 43784 Manual

Saxby Lighting Magma 43784 Manual

Other Saxby Lighting Floodlight manuals

Saxby Lighting 91860 User manual

Saxby Lighting

Saxby Lighting 91860 User manual

Saxby Lighting 78963 Manual

Saxby Lighting

Saxby Lighting 78963 Manual

Saxby Lighting Deluge PRS250 Manual

Saxby Lighting

Saxby Lighting Deluge PRS250 Manual

Saxby Lighting 107632 User manual

Saxby Lighting

Saxby Lighting 107632 User manual

Saxby Lighting Olea Manual

Saxby Lighting

Saxby Lighting Olea Manual

Saxby Lighting Vanguard RP500 User manual

Saxby Lighting

Saxby Lighting Vanguard RP500 User manual

Saxby Lighting Vanguard User manual

Saxby Lighting

Saxby Lighting Vanguard User manual

Saxby Lighting Scimitar Series Manual

Saxby Lighting

Saxby Lighting Scimitar Series Manual

Saxby Lighting 108672 User manual

Saxby Lighting

Saxby Lighting 108672 User manual

Saxby Lighting 48742 Manual

Saxby Lighting

Saxby Lighting 48742 Manual

Saxby Lighting 98443 User manual

Saxby Lighting

Saxby Lighting 98443 User manual

Saxby Lighting Laryn 5278J Manual

Saxby Lighting

Saxby Lighting Laryn 5278J Manual

Saxby Lighting Salde User manual

Saxby Lighting

Saxby Lighting Salde User manual

Saxby Lighting Max User manual

Saxby Lighting

Saxby Lighting Max User manual

Saxby Lighting Mantra 78971 User manual

Saxby Lighting

Saxby Lighting Mantra 78971 User manual

Popular Floodlight manuals by other brands

V-TAC VT-5192S installation instructions

V-TAC

V-TAC VT-5192S installation instructions

Major tech HLF30CW instruction manual

Major tech

Major tech HLF30CW instruction manual

EuroLite LED Cube user manual

EuroLite

EuroLite LED Cube user manual

EuroLite LED IP FL-100 SMD user manual

EuroLite

EuroLite LED IP FL-100 SMD user manual

Cooper Wheelock XB12 specification

Cooper Wheelock

Cooper Wheelock XB12 specification

Allen + Roth 17624-000 user manual

Allen + Roth

Allen + Roth 17624-000 user manual

ADJ 4 STAGE PAK User instructions

ADJ

ADJ 4 STAGE PAK User instructions

Cooper Lighting EGL91SW233 Specification sheet

Cooper Lighting

Cooper Lighting EGL91SW233 Specification sheet

Max 37496 instruction manual

Max

Max 37496 instruction manual

BEGA 85 143 Instructions for use

BEGA

BEGA 85 143 Instructions for use

Cameo CLPST64Q8W user manual

Cameo

Cameo CLPST64Q8W user manual

Beamz 151.226 user manual

Beamz

Beamz 151.226 user manual

EuroLite LED IP FL-8 user manual

EuroLite

EuroLite LED IP FL-8 user manual

Ledj PERFORMER 36 RGB user manual

Ledj

Ledj PERFORMER 36 RGB user manual

Perel ELS3 user manual

Perel

Perel ELS3 user manual

Perel ELS3WD user manual

Perel

Perel ELS3WD user manual

Xtricity 4-80053 instructions

Xtricity

Xtricity 4-80053 instructions

Stahl 6521/4 Series operating instructions

Stahl

Stahl 6521/4 Series operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

• Thissystemcontainsnon-replaceablepartsand
cannotbeserviced.Ifdamageoccursthepartshould
bescrapped.
Instructionleaflet
Magma Flood Light
43784
www.saxbylighting.com
Foryoursafety,alwaysswitchoffthesupplybeforecleaning.
Wasteelectricalproductsshouldnotbedisposedofwithhouseholdwaste.Pleaserecyclewherefacilities
exist.CheckwithyourLocalAuthorityorretailerforrecyclingadvice.
Recycling advice
Safety information
SaxbyLightingLtd.BH233PE
Werecommendcleaningwithasoftdrycloth.
Donotusesolventsorabrasivecleanersasthesecould
damagethefinish.
The LED's are protected by a lens. This part must be replaced immediately should the lens become
cracked or damaged. This fitting must not be used without the lens in place.
ReplaceCracked
Shade
Fitting/replacing bulbs
Iss.109052012
• Refitthebaseontotheproductusingscrews(A).
• Locate the product over the drilled holes and fix in
positionusingscrews(C).
• Adjustthefloodlightheadtothedesiredangle.
• Replacefuse orcircuit breaker and switchon. Your
lightisnowreadyforuse.
Commissioning
Check that...
• Youhavecorrectlyidentifiedthewires.
• Theconnectionsaretight.
• Noloosestrandshavebeenleftoutoftheconnection
block.
Thankyouforpurchasingthislightfitting.Pleasereadtheinstructionscarefullybeforeusetoensuresafeand
satisfactoryoperationofthisproduct.Pleaseretaintheseinstructionsforfuturereference.
Warning
This is a Class 1 product and must be earthed.
Pleasereadtheseinstructionscarefullybefore
commencinganywork.
Thisunitmustbefittedbyacompetentandqualified
electrician.
InstallinaccordancewithIEEWiringregulationsand
currentBuildingRegulations.
Topreventelectrocutionswitchoffatmainssupply
beforeinstallingormaintainingthisfitting.Ensure
otherpersonscannotrestoretheelectricalsupply
withoutyourknowledge.Ifyouareinanydoubt,
pleaseconsultaqualifiedelectrician.
Thislightfittingshouldbeconnectedtoacircuitwitha
30mARCDfitted.
Ifreplacinganexistingfitting,makeacarefulnoteof
theconnections.
Theunitcannotbedimmed.
Thissystemcontainsnon-replaceablepartsand
cannotbeserviced.Ifdamageoccursthepartshould
bescrapped.
Wasteelectricalproductsshouldnotbedisposedof
withhouseholdwaste.Pleaserecyclewherefacilities
exist.Checkwithyourlocalauthorityorretailerfor
recyclingadvice.
ThisproductisratedatIP65.
Thisproductisnotsuitableforlocationinorneara
marineenvironment.
Theentireunitgetshotwhilstonforaperiodoftime.
Specification
Voltage: 240V~50Hz
Lamp: 15x1WCreeLED’s
IPrating: 65
Layout
• Planthedesiredlayoutofthisfittingcarefully,
ensuringthecableswillreachthedistancebetween
thejunctionboxandthelightfitting.
• Avoidlocatinganycablesinpositionsthatwould
causeahazard.Positioncablesandoutdoorrated
junctionboxes(notsupplied)awayfromareas
wheretheymaybeatriskfrombeingcut,trappedor
damaged.
• Theinstallationofthepowercableandconduitmust
meetnationalandlocalstandards.Anyillustrations
showingtheconduitandcableareonlyaguide.The
typeanddepthofconduitandcablemayvaryfrom
areatoarea.Contactaqualifiedelectriciantocarry
outthiswork.
• Thisisafloodlightproduct,andthereforeshouldbe
positionedwhereitwillnotcauseaglarehazard.
Existingfittingsmustbecompletelyremovedbefore
installationofanewproduct.Beforeremovingthe
existingfitting,carefully note the position of each set
of wires.
• Decideontheoptimumlocationfortheproduct.
• Undothethreescrews(A),andsetside.Remove
baseplate.
• Theproductmustbemountedontoaconcretebase
orpavingslab.Itshouldnotbedirectlyinstalledon
thesoil.Detailsoffixingpositionsaregivenbelowin
Fig1.Verifythebasefitsbeforedrilling.
• Drillandplug(B)theatthemarkedpositions.
• Wireasdetailedbelow.
Installation
NEUTRAL
EARTH(GREEN/YELLOW)
SWITCHEDLIVE
BLUE(N)
GREEN/YELLOW
BROWN(L)
SUPPLY LIGHTFITTING
Removethecoverfromtheconnectorblockontopof
theunit.Connecttheoutputcableofthetransformerto
theterminalsindicatedbelow:
Wiring
120˚
120˚
120˚
116mm Dia
1. 2.
A
B
C