Warning
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Layout
Plan the desired layout of these fittings carefully, ensuring the cables will reach the distance between the junction
box (not supplied) and the light fitting.
Avoid locating any cables in positions that would cause a hazard. Position cables and outdoor rated junction boxes
(not supplied) away from areas where they may be at risk from being cut, trapped or damaged.
This product is supplied with 1 metres of H05RN-F outdoor grade rubber sheathed cable ready for connection to an approved,
outdoor rated terminal block which is not supplied and must be obtained. The mains supply cable must have a minimum
cross sectional area of 1.0mm2
Cables must be protected using suitable conduit or plastic trunking.
This is a floodlight product, and therefore should be positioned where it will not cause a glare hazard.
Wiring
Terminal block not included. Installation may require advice from a qualified person. Connect to an approved outdoor rated
terminal block, observing the wiring diagram here.
Installation
• Hold the product in position and mark the location of the fixing holes. A minimum of two fixing points must be used.
Ensure the wall is capable of holding the weight of the product. The bracket can be removed from the fitting for ease
of installation.
• Drill and plug the wall at the marked positions.
• Wire as detailed wiring.
• Refit the cover on the IP terminal block. Ensure that the seals are correctly located, and refit the screws.
• Fix the bracket to the wall using the screws and plugs (not supplied). Take care to avoid damaging any concealed
wiring and pipes. The correct fixings should be used for brick or cavity walls.
• Using the allen key (not supplied), loosen the bolts on the side, and adjust the fitting to the desired position. Ensure
that the cable is not snagged. Re-tighten the bolts.
This is a Class 1 product and must be earthed.
Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Install in accordance with the IEE Wiring regulations and current Building Regulations.
Check the pack and make sure you have all the parts listed.
To prevent electrocution switch off at the mains supply before installing or maintaining this fitting. Ensure other persons cannot
restore the electrical supply without your knowledge.
This light fitting should be connected to a circuit with a 30mA RCD fitted.
If replacing an existing fitting, make a careful note of the connections.
The entire unit gets hot whilst on for a period of time.
This product is not suitable for location in or near a marine environment.
The external flexible cable or cord of this luminaire cannot be replaced. If the cord is damaged, the luminaire must be
destroyed.
Terminal block not included. Installation may require advice from a qualified person.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with
your local authority or retailer for recycling advice.
SUPPLY LIGHT FITTING
BLUE (N)
NEUTRAL
EARTH
SWITCHED LIVE BROWN (L)
GREEN / YELLOW • You have correctly identified the wires.
• The connections are tight.
• No loose strands have been left out of
the connection block.
Check that...
Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully
note the position of each set of wires.
Note that the switch is turned off before installation.
Ensure that the screws and cable entry points are sealed to maintain the IP rating of the product.