2
Operating instructions
Safety switch SHG/SCG/SDG
EN
1.6 Warning about misuse
In case of improper use or manipulation of the safety
switchgear, personal hazards or damages to machinery
or plant components cannot be excluded. The relevant
requirements of the standard EN 1088 must be observed.
1.7 Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from
defective mounting or failure to comply with this operating instructions
manual. The manufacturer shall accept no liability for damages
resulting from the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary
repairs, conversions and modifications to the device are strictly
forbidden; the manufacturer shall accept no liability for damages
resulting from such invasive work, arbitrary repairs, conversions and/or
modifications to the device.
2. Product description
2.1 Ordering code
This operating instructions manual applies to the following types:
SHG
➀
/
➁
No. Option Description
➀
01 Head positioned to the front
02 Head positioned to the left
03 Head positioned to the right
04 Head positioned to the rear
➁
103/90 1 NC /1 NO slow action switch
220/110 2 NC slow action switch
92/90 1 NC / 1 NO snap action switch
SCG
➀
/
➁
No. Option Description
➀
01 Head positioned to the front
02 Head positioned to the left
03 Head positioned to the right
04 Head positioned to the rear
➁
103 1 NC /1 NO slow action switch
220/110 2 NC slow action switch
92/90 1 NC / 1 NO snap action switch
SDG
➀
/
➁
No. Option Description
➀
01 Head positioned to the front
02 Head positioned to the left
03 Head positioned to the right
04 Head positioned to the rear
➁
1103 2 NC /1 NO slow action switch
3330 3 NC slow action switch
3440 3 NC gradually slow action
1044 1 NC /2 NO slow action switch
Only if the information described in this operating instructions
manual are realised correctly, the safety function and
therefore the compliance with the Machinery Directive is
maintained.
2.2 Special versions
For special versions, which are not listed in the order code below 2.1,
these specifications apply accordingly, provided that they correspond to
the standard version.
2.3 Purpose
The SHG, SCG, SDG safety switch has been designed to prevent, in
conjunction with the control part of a machine, movable safety guards
from being opened before hazardous conditions have been eliminated.
Safety switches can only be used for applications, in
which the hazardous situation is terminated without delay
(e.g. run-on movements) when the safety guard is opened.
When the safety guard is opened, the NC contacts are positively
opened and the NO contacts are closed.
The user must evaluate and design the safety chain in accordance with
the relevant standards and on the required safety level.
2.4 Technical data
Standards: IEC 60947-5-1; EN ISO 13849-1;
EN 1088; BG-GS-ET-15
Enclosure: Aluminium
Actuator: steel
Contact material: Silver
Protection class: IP67
Contact type: change-over with double break Zb,
or 2 NC contacts, or 3 NC contacts,
galvanically separated contact bridges
Switching system:
A
IEC 60947-5-1, slow or snap action, NC
contacts with positive break
Connection: screw terminals
Cable type: solid wire
Cable section: 0.5 … 2.5 mm²
Cable type: stranded wire
Cable section: 0.5 … 1.5 mm²,
with conductor ferrules,
Cable entry: M20 × 1.5 ; SCG and SDG 3 × M20 x 1.5
Actuating speed: 0.2 m/s
Actuating frequency: max. 1200 operations/h
Mechanical life: > 1 million operations
Ambient temperature: − 25°C … + 70°C
Utilisation category: AC-15, DC-13
Ie/Ue:8 A / 230 VAC; 5 A / 24 VDC
6 A / 230 VAC; 4 A / 24 VDC only snap action
Ui: 400 V
Uimp:2.5 kV
Ithe:10 A
Us:24 VAC / DC 110 / 230 VAC
Max. fuse rating: 10 A gG D-fuse
2.5 Safety classification
Standards: EN ISO 13849-1
B10D (NC contact): 2,000,000
B10D (NO contact) at 10% ohmic contact load: 1,000,000
Service life: 20 years
TF
D
10Dopop
op
n
(Specifications can vary depending on the application-specific
parameters hop, dop and tcycle as well as the load.)