SDC EntryCheck 918W User manual

P:\ INST INSTRUCTIONS\ACCESS CONTROLS\INST-918W Rev A 11-21 Page 1
918W
EntryCheck TM
Features
12 key illuminated 3x4 digital keypad with configurable
illumination: always on, timed, off
Suitable for Indoor use
Standard 26-bit Wiegand output for universal
compatibility
Programmable Site Code
Programmable Keypad Operation
Single-gang mount
Two LED status indicators
Audible annunciation of keystrokes with adjustable
sound level: normal, low, off
Tamper-resistant screws
Moisture-resistant keys
Includes wiring harness
Operating Voltage: 5 - 16 Volts DC
Current Consumption: 25mA (typical), 40 mA (max)
Operating Temperature: -10° to 130°F (-23° to 54°C)
Humidity: 5% to 95% non-condensing
Dimensions (H x W x D): 4.75" x 3" x 1",
(0.25" wall projection)
Faceplate: Vandal-resistant S.S., 2mm Thick
Cabling: 6" wiring harness
Keypad Output: 26-bit Wiegand
Max. Cable Distance to Host: 328ft (100m) @12VDC,
100ft (30m) @ 5VDC, using 18AWG cabling
Recommended Cable (shielded, multi-conductor) or
equal:
-Belden 5504FE (6 Cond)
Specifications
Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email [email protected]
The EntryCheck™ 918W Wiegand indoor digital keypad is designed to interface with most Access Control Systems.
The moisture-resistant keypad provides a standard 26-bit Wiegand output.
The backlit keys are bright and easy-to-read. The 918W keypad is mounted on a rugged, stainless steel faceplate and is
designed to be mounted in a standard single-gang electrical box.
Two long lasting solid state LED indicators show the status of the system. The left bi-color indicator lights red to indicate
power, or green to indicate an authorized access (controlled externally by host). The right indicator flashes yellow to
indicate that the keypad is in programming mode.
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: service@sdcsecurity.com ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
INSTALLATION INSTRUCTIONS

P:\ INST INSTRUCTIONS\ACCESS CONTROLS\INST-918W Rev A 11-21 Page 2
918W WIRING
See Fig. 3 for an example of a basic door installation.
The 918W is mounted adjacent to the door. An electric
door strike is mounted in the door jamb to release the
door lock. A magnetic switch is mounted on top of the
door jamb for detecting when the door is open. The
access host controller is located at a maximum distance
of 300ft of the keypad reader, depending on the reader
voltage provided.
Refer to the Fig. 4 or Fig. 5 for wiring details.
To avoid damage to the unit from static discharges,
mount the faceplate to a good earth grounding point.
Suggested wiring size is 18 AWG for earth ground.
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: service@sdcsecurity.com ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
Fig. 3 Basic Door Installation
6 wires for
KP Reader
SDC IP Pro™ Single Door Controller
or 3rd Party Access Control
2 wires for
Door Sensor
2 wires for
Strike Power
918W
Keypad
2 wires for
Remote
Release
Fig. 4 Wiring Harness Connections
WireColor Designation
RED +VDC(5‐16V)
BLACK GND
WHITE WIEGANDD1
GREEN WIEGANDD0
ORANGE GREENLEDCONTROL
YELLOW BUZZERCONTROL
918WWiringHarnessConnections
Fig. 5 Installation Wiring to IPDCE Single-Door Controller
WIRING
HARNESS
RED
BLK
WHT
GRN
ORG
YEL Buzzer
SDC P
/N:
IPDCE or IPDSE
SENSE
CLOCK
DATA
+12V
0V
RED
GREEN
BEEPER
LEVEL
JUMPER
(JP1)
MASTER
CODE
RESET
JUMPER
(JP2)
S.S.
FACEPLATE
Fig. 1 Keypad (Back)
6-PIN WIRING
HARNESS
YELLOW
“PROGRAM”
INDICATOR
KEYPAD
RED/GREEN
POWER/ACCESS
INDICATOR

P:\ INST INSTRUCTIONS\ACCESS CONTROLS\INST-918W Rev A 11-21 Page 3
FACTORY DEFAULTS
Master Programming Code………..………………..….…...123456
Keypad Output Mode……………………...……..…26-bit Wiegand
Keypad Output Site Code……………………………………..…000
Beeper Sounds When Key Pressed……….…………...………Yes
Beeper Volume……………………………………….….……Normal
Keypad Backlight Mode…………………..…30 sec after activation
Keypad Timeout………………………………..………..………5 sec
918W OPERATION
The 918W EntryCheck™ keypad will emulate a reader credential.
Entering a ‘card’ number followed by ‘#” will transmit the
programmed facility code plus the card number as a 26-bit
Wiegand output. The card number entered must be > 0 and <
65,535.
For example, if the default Facility Code has been changed to
123, pressing 1234 + #, will send ‘12301234’ as the complete
card number.
Entering Programming Mode
The 6-digit Master Programming Code (default = 123456) is
used to enter Programming Mode.
Press: # 9 # Master Code #
Master Code = the current 6-digit Master Programming Code
BASIC PROGRAMMING
While the 918W is in Programming Mode the yellow indicator
will blink slowly.
After a programming function is selected, the yellow indicator
will flash rapidly while the keypad is waiting for user input data.
You will have 5 sec. between programming commands once a
function is selected. The green indicator will light if the data is
accepted. The red indicator will light if any programming data
is entered incorrectly, and the function will have to be fully re-
entered.
Exiting Programming Mode
Press: #
The red indicator will light after exiting Programming Mode
Note: The 918W will automatically exit Programming Mode after
2 minutes of inactivity
**
Changing the 6-Digit Master Programming Code
It is recommended that the Master Programming Code be
changed after the installation is finalized.
Press: 98 # Master Code # Master Code #
Master Code = The new 6-digit Master Programming Code
Changing the Beeper Sound Level
The Keypad’s beeper can be set to normal or low level.
Remove jumper JP1 to reduce beeper sound level.
See Page 2 for the location of JP1.
PROGRAMMING FUNCTIONS
Enter Programming Mode before performing any of the following
functions.
Beep Sounds on Keystrokes Default: Yes
Selects whether or not the keypad beeps as each key is pressed.
Press: 40 # Sound #
Sound=1 for Yes, =0 for No
Selects mode for Keypad LED Backlight Default: 30 Secs.
Selects whether or not the keypad back light stays OFF, lights for
30 seconds when activated or stays ON.
Press: 52 # Output #
Output = 0, Light always OFF
= 1, 30 sec light when activated (default)
= 2, Light always ON
Change Facility (Site) Code Default: 000
Selects the Site Code when using the Keypad in Weigand Mode.
Press: 82 # Site Code #
Site Code = New 3-Digit Site Code (000-255)
Master Reset
Resets all programming options.
NOTE: The Master Code will NOT be reset.
STEP 1 Disconnect power from the keypad.
STEP 2 Press and hold down the * and # keys.
STEP 3 Apply power to the keypad, continue holding the keys
down until the red indicator starts flashing
STEP 4 Release the keys. The red and yellow indicators will
remain lit until the process is complete, then the yellow
indicator will go out.
Resetting the Master Code
STEP 1 Remove the 918W from the wall and disconnect
power from the keypad.
STEP 2 Locate & remove jumper JP2. Reference page 2.
STEP 3 Re-apply power. You will get a single beep and
the yellow LED will flash momentarily.
STEP 4 Replace jumper on JP2. The Master Code is now
123456.
RESETTING THE KEYPAD READER
ERROR ANNUNCIATION (Wiegand Mode only)
KeypadAction Indication
Keypresstimeout(instandby) DoubleBeep
0,ornumber>=65535isentered RedLEDflashw/beep(x3)
*isentered RedLEDflashw/beep(x3)
MasterCodeerror RedLEDflashw/beep(x3)
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: service@sdcsecurity.com ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
Other SDC Keypad manuals
Popular Keypad manuals by other brands

Vuescape
Vuescape 61000108 Installation & user guide

Access security product
Access security product KP-401-A user manual

motortronics
motortronics VMX-synergy VMX-SGY-010 user guide

Honeywell Home
Honeywell Home ADEMCO 6150 Installation and setup guide

DSC
DSC HS2LCDWF v1.0 installation instructions

Lutron Electronics
Lutron Electronics SQE-2 manual