manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. SDC
  6. •
  7. Lock
  8. •
  9. SDC 1490A User manual

SDC 1490A User manual

Other SDC Lock manuals

SDC Z7730 Series User manual

SDC

SDC Z7730 Series User manual

SDC HI-SHEAR EMLOCKS 1565 User manual

SDC

SDC HI-SHEAR EMLOCKS 1565 User manual

SDC E75 Series User manual

SDC

SDC E75 Series User manual

SDC 1581S User manual

SDC

SDC 1581S User manual

SDC 295 User manual

SDC

SDC 295 User manual

SDC 2490A User manual

SDC

SDC 2490A User manual

SDC FS23M Series User manual

SDC

SDC FS23M Series User manual

SDC Z7800 SERIES User manual

SDC

SDC Z7800 SERIES User manual

SDC LR100KWK-EM User manual

SDC

SDC LR100KWK-EM User manual

SDC 280 series User manual

SDC

SDC 280 series User manual

SDC 2000 Series User manual

SDC

SDC 2000 Series User manual

SDC CL600 Series User manual

SDC

SDC CL600 Series User manual

SDC 352 User manual

SDC

SDC 352 User manual

SDC Excel E1200 User manual

SDC

SDC Excel E1200 User manual

Popular Lock manuals by other brands

COMPX MFW 29118 Dimensional drawing

COMPX

COMPX MFW 29118 Dimensional drawing

Magic 105 manual

Magic

Magic 105 manual

Gantner GAT NET.Lock 7020 System Installation, configuration & operation

Gantner

Gantner GAT NET.Lock 7020 System Installation, configuration & operation

Wittkopp Insys 7202 manual

Wittkopp

Wittkopp Insys 7202 manual

Glutz 50022 Fixing instructions

Glutz

Glutz 50022 Fixing instructions

Dorma Studio Classic Installation instruction

Dorma

Dorma Studio Classic Installation instruction

Securam ECSL-601 quick start guide

Securam

Securam ECSL-601 quick start guide

Sudhaus 3003 operating manual

Sudhaus

Sudhaus 3003 operating manual

Safety 1st 48517 user guide

Safety 1st

Safety 1st 48517 user guide

Pado FDS-10 user manual

Pado

Pado FDS-10 user manual

Esco systeQ Series installation instructions

Esco

Esco systeQ Series installation instructions

COMPX National D8951 instruction sheet

COMPX

COMPX National D8951 instruction sheet

secureo Key Box instruction manual

secureo

secureo Key Box instruction manual

Stock Loks C8713 instruction sheet

Stock Loks

Stock Loks C8713 instruction sheet

COMPX 1T-058 Information

COMPX

COMPX 1T-058 Information

Auslock T11 user manual

Auslock

Auslock T11 user manual

ELCOM 7205 Operating	 instruction

ELCOM

ELCOM 7205 Operating instruction

Stealth SAFES ShadowVault Instructions & Troubleshooting

Stealth SAFES

Stealth SAFES ShadowVault Instructions & Troubleshooting

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1490A
EXTRA NARROW CONCEALED MORTISE BOLT LOCK
FAIL-SAFE
P:\INST INSTRUCTIONS\BOLT LOCKS\INST-1490A REV E 12-21 Page 1
Easy Installation or Servicing
All Space Saver locks are
easily installed in any existing
entrance merely by mortising
out a cutout, attaching the
wiring, inserting the lock, and
bolting it into position with two
attaching tabs. Cutting studs is
no longer a problem or
expense.
Fig. 2
Auto Relock Switch
Adjustable for Wide Door Gap
Loosen nut.
Turn assembly
clockwise for wide
door gap.
Tighten nut.
Fig. 1
OVERHEAD INSTALLATION HORIZONTAL
1. Examine the top rail of the door for the most suitable location for the strike plate. Mark the door for the end of the strike closest to
the lock stile, and make a corresponding mark on the header to line up with the first mark.
2. Locate center line of door thickness on the header and attach adhesive cut out template to header. Lining it up with marks, center
punch the tab-mounting screw locations and counter-sink for #10 screw. Saw or rout out the cutout area. Continue to step 5.
SIDEJAMB INSTALLATION VERTICAL
3. Examine the lock stile jamb for the point nearest the center of the door height, with space available for the lock and strike. Mark
the door stile horizontal for the top end of the strike plate and make a corresponding mark on the jamb.
4. Locate center line of door thickness on the jamb and attach adhesive cutout template to jamb, lining up the the top of the cutout
with the horizontal mark on the jamb. Center punch the tab mounting screw locations and counter sink for #10 screw. Saw or rout
the frame cutout.
5. Attach the mounting tabs inside.
6. Attach power supply and access control leads to lock leads as shown on page 2. Handle the lock carefully; do not hang it by the
wire leads. Insert wiring into the header cavity carefully so they do not interfere with proper locating of the lock in the cutout.
7. Insert lock. When installed overhead horizontally, the bolt end is nearest the lock stile. When installed vertically on the sidejamb,
the bolt must be at the top end of the cutout. Secure with # 10-32 machine screw.
8. Using strike plate as a template, mark screw hole location and drill holes for screws supplied. Mortise as required. Attach strike.
9. The automatic relock switch is set for 1/8” clearance between the top of the door and transom bar or head jamb. Any additional
gap may be compensated for by loosening the lock nut and turning the switch assembly clockwise until proper adjustment is
reached. Be sure to tighten lock nut when adjustment is satisfactory.
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: [email protected] ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: [email protected] ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
INSTALLATION INSTRUCTIONS
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: [email protected] ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
INSTALLATION INSTRUCTIONS
Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email engineer@sdcsecurity.com
1. Mortise cutout in
tube for face plate
(fits flush with
surface of tube).
2. Position screws
for attaching
tabs, drill holes,
attach tabs.
4. Slide lock into
position, attach
to tabs.
3. Connect wiring
to lock.
1. Mortise cutout in
tube for face plate
(fits flush with
surface of tube).
2. Position screws
for attaching
tabs, drill holes,
attach tabs.
4. Slide lock into
position, attach
to tabs.
3. Connect wiring
to lock.
P:\INST INSTRUCTIONS\BOLT LOCKS\INST-1490A REV E 12-21 Page 2
LOCK WIRING
NOTE: The SDC PR-1000 Power Regulator is included with the bolt lock. Although the solenoid is rated for continuous
duty, continuously powering the solenoid will generate heat. Installing the PR-1000 reduces the power consumption of
the bolt lock after activation of the lock, allowing for a heat reduction to the bolt lock, and increasing the life of the
solenoid. DC voltage is recommended for improved heat reduction.
1490A (without PR-1000):
1490A (Wiring with PR-1000; recommended):
PR1000 Input Voltage: 12/24 VDC/AC (+/-10%). DC voltage is recommended for optimal performance
Problem Solution
Bolt does not project Check voltage and alignment of
strike.
Bolt projects but chatters Voltage too low.
Bolt will not retract Strike misaligned
RED=N/C
WHT= COM
BLU=N/O
RED=N/C
WHT = COM
BLU=N/O
DPS
DPS /BPS CONFIGURATION
BPS
DPS polarity shown with door closed
.
BPS polarity shown with bolt retracted
.
D Indicates door opened or closed 4A @ 30VDC (Resistive)
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: [email protected] ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: [email protected] ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: [email protected] ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: [email protected] ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
ELECTRICAL DATA:
Dual Voltage Solenoid (1490A)
12VDC@ .9 Amp (max.)
24VDC@ .45 Amp (max.)
Continuous Duty
RED (+)
BLU
BLK
12VDC SOLENOID
CONFIGURATION
12VDC @
.9A (max)
RED (+)
BLK
BLU
WHT (-)
24VDC @
.45A (max)
24VDC SOLENOID
CONFIGURATION
WHT (+)
ELECTRICAL DATA:
Dual Voltage Solenoid (1490A)
12VDC@ .9 Amp (max.)
24VDC@ .45 Amp (max.)
Continuous Duty
RED (+)
BLU
BLK
12VDC SOLENOID
CONFIGURATION
12VDC @
.9A (max)
RED (+)
BLK
BLU
WHT (-)
24VDC @
.45A (max)
24VDC SOLENOID
CONFIGURATION
WHT (+)
**AC Power requires
the PR-1000
PR-1000
VOLTAGE
REGULATOR
YEL/BLK (~)
YEL (~) or (+DC)
(-)
+
Access
Control or
Push Button
(N/C)
N/O
N/C
COM
AC
POWER**
BLK (-DC)
RED (+)
WHT (-)
ORG
BLU
WHT/BLK
Not
Used
(~)
(~) DC
POWER
INPUT
Solenoid Lock ARS
(DOOR CLOSED)
YEL YEL
*See below for
solenoid wiring
PR-1000
VOLTAGE
REGULATOR
YEL/BLK (~)
YEL (~) or (+DC)
(-)
+
Access
Control or
Push Button
(N/C)
N/O
N/C
COM
AC
POWER**
BLK (-DC)
RED (+)
WHT (-)
ORG
BLU
WHT/BLK
Not
Used
(~)
(~) DC
POWER
INPUT
Solenoid Lock ARS
(DOOR CLOSED)
YEL YEL
*See below for
solenoid wiring
**AC Power requires
the PR-1000
PR-1000
VOLTAGE
REGULATOR
YEL/BLK (~)
YEL (~) or (+DC)
(-)
+
Access
Control or
Push Button
(N/C)
N/O
N/C
COM
AC
POWER**
BLK (-DC)
RED (+)
WHT (-)
ORG
BLU
WHT/BLK
Not
Used
(~)
(~) DC
POWER
INPUT
Solenoid Lock ARS
(DOOR CLOSED)
YEL YEL
*See below for
solenoid wiring
Solenoid Voltage Configuration:
TROUBLESHOOTING OPTIONAL BOLT POSITION SENSOR (BPS-MAGNETIC)
B Indicates bolt locked or unlocked 5 Watt
OPTIONAL DOOR POSITION SWITCH (DPS-MECHANICAL)
(-)
+
Access
Control or
Push Button
(N/C)
N/O
N/C
COM
DC
POWER
INPUT
Solenoid* +
(-)
Lock ARS
(DOOR CLOSED)
YEL YEL
(-)
+
Access
Control or
Push Button
(N/C)
N/O
N/C
COM
DC
POWER
INPUT
Solenoid* +
(-)
Lock ARS
(DOOR CLOSED)
YEL YEL