manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. SDC
  6. •
  7. Lock
  8. •
  9. SDC 352 User manual

SDC 352 User manual

Other SDC Lock manuals

SDC 295 User manual

SDC

SDC 295 User manual

SDC LR100KWK-EM User manual

SDC

SDC LR100KWK-EM User manual

SDC E75 Series User manual

SDC

SDC E75 Series User manual

SDC FS23M Series User manual

SDC

SDC FS23M Series User manual

SDC 2490A User manual

SDC

SDC 2490A User manual

SDC Z7730 Series User manual

SDC

SDC Z7730 Series User manual

SDC 2000 Series User manual

SDC

SDC 2000 Series User manual

SDC 280 series User manual

SDC

SDC 280 series User manual

SDC CL600 Series User manual

SDC

SDC CL600 Series User manual

SDC Z7800 SERIES User manual

SDC

SDC Z7800 SERIES User manual

SDC 1581S User manual

SDC

SDC 1581S User manual

SDC Excel E1200 User manual

SDC

SDC Excel E1200 User manual

SDC HI-SHEAR EMLOCKS 1565 User manual

SDC

SDC HI-SHEAR EMLOCKS 1565 User manual

SDC 1490A User manual

SDC

SDC 1490A User manual

Popular Lock manuals by other brands

COMPX MFW 29118 Dimensional drawing

COMPX

COMPX MFW 29118 Dimensional drawing

Magic 105 manual

Magic

Magic 105 manual

Gantner GAT NET.Lock 7020 System Installation, configuration & operation

Gantner

Gantner GAT NET.Lock 7020 System Installation, configuration & operation

Wittkopp Insys 7202 manual

Wittkopp

Wittkopp Insys 7202 manual

Glutz 50022 Fixing instructions

Glutz

Glutz 50022 Fixing instructions

Dorma Studio Classic Installation instruction

Dorma

Dorma Studio Classic Installation instruction

Securam ECSL-601 quick start guide

Securam

Securam ECSL-601 quick start guide

Sudhaus 3003 operating manual

Sudhaus

Sudhaus 3003 operating manual

Safety 1st 48517 user guide

Safety 1st

Safety 1st 48517 user guide

Pado FDS-10 user manual

Pado

Pado FDS-10 user manual

Esco systeQ Series installation instructions

Esco

Esco systeQ Series installation instructions

COMPX National D8951 instruction sheet

COMPX

COMPX National D8951 instruction sheet

secureo Key Box instruction manual

secureo

secureo Key Box instruction manual

Stock Loks C8713 instruction sheet

Stock Loks

Stock Loks C8713 instruction sheet

COMPX 1T-058 Information

COMPX

COMPX 1T-058 Information

Auslock T11 user manual

Auslock

Auslock T11 user manual

ELCOM 7205 Operating	 instruction

ELCOM

ELCOM 7205 Operating instruction

Stealth SAFES ShadowVault Instructions & Troubleshooting

Stealth SAFES

Stealth SAFES ShadowVault Instructions & Troubleshooting

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

P:\INST INSTRUCTIONS\EMLOCKS\INST-352 REV -.5 10-22 Page 1
Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email engineer@sdcsecurity.com
352
NARROW LINE EMLOCK
Electrical Instructions:
Use properly fused U. L. Listed Power Supply
Do not install a diode in parallel with any magnetic lock. A diode
will cause a delay when releasing the door and residual magnetism
to occur.
Access controls and/or release contacts must be located in series
with the positive (+) power lead of the EmLock.
Any low voltage condition will cause erratic operation of the
optional board sensor.
Although SDC recommends the use of a Regulated DC power supply,
a significant voltage drop will occur when using a full wave bridge rectifier.
Installation Location – Indoor Dry use only
Electrical Specifications:
Dual Voltage: 12 or 24VDC
Power Consumption: 1120mA@12VDC
618mA@24VDC
DS Door Status Sensor: SPDT, 250mA@24VDC
LS Lock Status Sensor: SPDT, 1A@24VDC
Resistive
Outswing
Quick Mount
Interlocking
Mounting Assembly
Armature
Interlocking
Mounting Plate
Frame
Magnet Lock
Supplied Mounting Hardware
25"
2-1/4”
1-1/2”
3/4”
10"
2"
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: [email protected] ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
INSTALLATION INSTRUCTIONS
PATENT NO. 5,376.910
1. Fold template as indicated on dotted line. For double doors center template against the doors and header.
2. Mark and drill holes as indicated by the template.
HOLLOW METAL DOOR
From Sexnut side of door, drill exactly 1/2” hole thru one metal
thickness only. From Armature side of door, drill 5/8” hole to insert
reinforcement tube. Press in sexnut and reinforcement tube all the
way and mount armature to door using hardware provided.
3. Mount armatures to doors.
REINFORCEMENT
TUBE 1-3/4“ HOLLOW
METAL DOOR
5/8“ DRILL
STEEL WASHER 2X
RUBBER WASHER
5/16-18
Thread
WITH 3/16
ALLEN HEX
ARMATURE 1/2” DRILL
SEXNUT
P:\INST INSTRUCTIONS\EMLOCKS\INST-352 REV -.5 10-22 Page 2
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: [email protected] ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
Install Roll Pins to
Armature before
installing onto door.
Hardware used for Armature Install per door.
4. Install the Interlocking Mounting Plate to frame. Loosely fasten the 1/2" self drilling screws to the Mounting Plate as
shown below. Temporarily install the lock onto Mounting Plate and adjust the Mounting Plate and lock to the armature
spacing between the door and frame. Once adjusted remove lock and tightly fasten all mounting screws. Use the
appropriate mounting screw based on frame type.
Hardware used to install Interlocking Mounting Plates
For wood frame install use supplied 1-1/4"
wood screws.
For metal frame install use supplied
(M5 x 4mm) machine Screws
Use the supplied 1/2" screws to adjust the
interlocking mounting plate.
6. Select jumper position for 12VDC or 24VDC. Connect power to magnetic lock.
To maintain surface plating from corrosion:
 Do not touch the lock face with your hands.
 Clean lock face with Scotch-Brite pad by 3M (do not use sandpaper).
 Apply a thin film of rust inhibitor (LPS-3) on lock face.
 Repeat application on armature plate.
5. Holding the magnet housing at each end, engage the entire length of the interlock detail, by pushing towards the
door. Tap with a soft hammer to ensure proper alignment and engagement.
P:\INST INSTRUCTIONS\EMLOCKS\INST-352 REV -.5 10-22 Page 3
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: [email protected] ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
Use the supplied 5/32" Allen wrench
to secure lock
CAUTION: The lock body must be held in place until secured by mounting screws. Fasten the pre-installed socket head screws within the lock
at each end. Slowly fasten the screws to avoid stripping the threads. Pull wires through frame, interlocking mounting plate and magnet
housing
N/C
COM
N/O
-
-
-
ORG
WHT
YEL
DOOR POSITION SENSOR
1
+
2
-
3
NO
4
C
5
NC
Power
Supply
Voltage Jumper
12VDC
24VDC
Lock
Status
Switch
(Relay)
Door Position Sensor: (Reed switch)
COM
NC
NO
ORANGE (open with door closed)
YELLOW (closed with door closed)
WHITE
LED Status Indicator:
 RED – Energized and Unsecure GREEN – Energized and Secure
POWER
SUPPLY
12VDC
OR
24VDC
SWITCH or ACCESS
CONTROL
+
-
+
-
A/C
MAINS
7. Verify operation. When all is operating properly, close the cover and securely fasten all screws.