p WARNING! Ensure that you read, understand and apply the safety and operational instructions before connecting the insulation tester. Only
when you are sure that you understand the procedures is it safe to proceed with testing.
Operating temperature range: 0OC to 50OC.
Relative humidity: Maximum 80%.
3.
Check Internal Battery.
3.1. Set the power switch to ON.
3.2. Depress the insulation resistance pushbutton switch.
3.3. The 500V ON LED lamp should light, indicating normal operation from the internal batteries.
3.4. If the 500V ON LED fails to light the batteries are exhausted. Remove the rear cover by unscrewing the centrally located case
mounted screw and insert four new batteries observing the correct polarity.
3.5. Repeat the proccess 3.1. to 3.3. and turn the power switch to the OFF position having confirmed the battery condition as good.
4. Insulation Resistance Measurements
4.1. Connect the insulation tester terminals E, L and G to the meter terminals VΩ
W
,
,
COM and EXT respectively.
4.2. Set the meter switch to the insulation tester function and 2000MΩ
W
range position.
4.3. Connect a test probe to the L terminal and another to the E terminal on the insulation tester.
4.4. Connect one lead to one end of the circuit to be measured and the other lead to the other end.
4.5. Set the power switch to ON and the range to 2000Ω position.
4.6. Press the insulation resistance pushbutton. The 500V LED lampwill light and the resistance value will be displayed on the meter.
4.7. For open circuits or values of resistance over 2000MΩ, the meter will treat the resistance value as infinate and display a 1 only.
4.8. When measuring values of resistance below 10MΩ on the 2000MΩ range, the measurement error will be greater. Set the insulation
tester and the coupled meter to the 20MΩ position, and press the resistance pushbutton again to gain a new reading.
4.9. After completing your measurements return the insulation tester power switch to the OFF position.
Suitable for use with MM404 Digital Clamp Multimeter.
This insulation tester unit makes use of a DC-DC converter to 500V DC.
A two range insulation resistance tester (20MΩ and 2000MΩ) . Powered by four type
AA cells, providing up to 30 operating hours, depending on type of battery and
usage. Featuring a rugged design and ease of use.
Range: 20MΩ
W
(±2%), 2000MΩ
W
(±4%).
Rated Voltage: 500V DC.
Test Leads (pair).
Low battery indication: Yellow LED lamp lighted.
Operating temperature range: 0OC to 50OC. Relative humidity: Maximum 80%.
1.1. PERSONAL PRECAUTIONS
3When using this meter, please observe all normal safety rules concerning:
Protection against the dangers of electric current.
Protection of the meter against misuse.
3Full compliance with safety standards can only be guaranteed if used with the test leads supplied. If necessary, they must be replaced
with genuine Sealey leads with the same electronic ratings. Failure to do so will invalidate the warranty.
7DO NOT use leads if damaged or if the wire is bared in any way.
1.2. GENERAL SAFETY INSTRUCTIONS
3Familiarise yourself with the application and limitations of the insulation tester as well as the potential hazards.
IF IN ANY DOUBT CONSULT A QUALIFIED ELECTRICIAN.
3When the insulation tester is connected to a circuit, do not touch unused terminals.
3When the value scale to be measured is unknown, set the range selector to the highest value.
pWARNING! Never perform insulation measurements on live circuits.
3Always be careful when working with voltages above 60Vdc or 30Vac rms. Keep your fingers behind the probe barriers while measuring.
3When not in use, store the multimeter carefully in a safe, dry, childproof location. Storage temperature range - 10OC to 50OC.
INSTRUCTIONS FOR:
INSULATION TESTER ACCESSORY
MODEL: MM404.261
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained,
give you years of trouble free performance.
1. SAFETY INSTRUCTIONS
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT
CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL
INVALIDATE THE WARRANTY. PLEASE KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
2. FEATURES
3. OPERATION
Fig.1
Range Measurement Range Accuracy
20MΩ
W
100KΩ
W
- 19.99MΩ
W
± 2% of reading ± 2 digit
2000MΩ
W
10MΩ
W
- 2000MΩ
W
± 4% of reading ± 2 digit for 500MΩ
W
and below.
For others ± 5% of reading ± 2 digit
MM404.261 - 1 - 070105