OIL HOSE END METER DIGITAL
MODEL NO: AK4565D
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
WARNING! Ensure health & safety, local authority, and general workshop practice regulations are strictly adhered to when using this
equipment.
9 Familiariseyourselfwithproductapplicationandlimitations,aswellasthespecicpotentialhazardspeculiartothisproduct.
the pump station in good condition (use an authorised service agent).
9Replace or repair damaged parts. Use genuine parts only. Non authorised parts will invalidate the warranty.
9Use only to pump oils up to SAE 150 viscosity.
9Ensure safety eye protection and protective clothing are worn when using this product.
9Keep the work area clean, uncluttered and ensure there is adequate lighting.
9 Maintaincorrectbalanceandfooting.Ensuretheoorisnotslipperyandwearnonslipshoes.
9Keep children and unauthorised persons away from the working area.
9 Afteruse,drainanyuidsfromtheequipmentbeforestorage.
9Dispose of waste liquids in accordance with local authority regulations.
8DO NOT exceed the maximum pressure of 750psi.
8DO NOTpointthenozzleatpeopleoranimals.
8DO NOTusetheequipmentnearopenames.
8DO NOT smoke whilst using this equipment.
8DO NOTusetoextractcorrosiveuids.
8DO NOT dismantle, tamper with or adapt the equipment for any purpose other than for which it is designed.
8DO NOT use the unit if it has been dropped or mishandled, check the unit to ensure there is no damage.
9Keep the pump clean and store in a safe dry, childproof location.
WARNING! DO NOTallowuncontrolleddischargeofuidsthuspollutingtheenvironment.Allliquidsmustbedisposedofaccordingto
local authority regulations.
2. i INTRODUCTION
Robustoildispensinggunincorporatingdigitalmeter,manualshutoandtoughrubberprotectionguard.Fittedwithexibleextension
andnon-dripnozzle.Easytoread5-digitLCDdisplaywithresettableindividualorcumulativetotals.
3. i SPECIFICATION
Model No: ...............................................................AK4565D
Maximum Flow Rate: ............................................... 35ltr/min
Accuracy: .....................................................................±0.5%
InletSize: ..................................................................1/2”BSP
Battery .......................................... LithiumCR23V1400mAh
4. ASSEMBLY
4.1. Removetheblankingplugfromtheoutletendofthemeter.Ensurethatthethreadsonthenozzlepipeassemblyarecleanandapply
some liquid thread sealant onto the male connection. Screw both parts together and tighten.
NOTE: DO NOT apply too much thread sealant and ensure that none gets into the meter.
4.2. Remove the blanking plug from the handle end and connect to the male end of the supply hose.
WARNING! DO NOT overtighten as this may cause damage to the swivel connection.
WARNING! Ensure that the system pressure does not exceed the 750psi of the digital meter.
Original Language Version
© Jack Sealey Limited
Refer to
instruction
manual
Wear protective
gloves
Wear eye
protection
Wear protective
clothing
AK4565 Issue 2 (H, 5, 6, F) 24/05/18