logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Sealey
  6. •
  7. Measuring Instrument
  8. •
  9. Sealey Professional AUTO SERVICE TA100 User manual

Sealey Professional AUTO SERVICE TA100 User manual

Other Sealey Measuring Instrument manuals

Sealey PP5 User manual

Sealey

Sealey PP5 User manual

Sealey PPLK User manual

Sealey

Sealey PPLK User manual

Sealey DBG507 User manual

Sealey

Sealey DBG507 User manual

Sealey TP91300.V2 User manual

Sealey

Sealey TP91300.V2 User manual

Sealey GA45 User manual

Sealey

Sealey GA45 User manual

Sealey TP67DT.V2 User manual

Sealey

Sealey TP67DT.V2 User manual

Sealey MM405 User manual

Sealey

Sealey MM405 User manual

Sealey VS0052 User manual

Sealey

Sealey VS0052 User manual

Sealey BT91/5.V3 User manual

Sealey

Sealey BT91/5.V3 User manual

Sealey TA070 User manual

Sealey

Sealey TA070 User manual

Sealey TA303 User manual

Sealey

Sealey TA303 User manual

Sealey VS925.V2 User manual

Sealey

Sealey VS925.V2 User manual

Sealey VSE3157 User manual

Sealey

Sealey VSE3157 User manual

Sealey AK9635D.V3 User manual

Sealey

Sealey AK9635D.V3 User manual

Sealey DBG5010 User manual

Sealey

Sealey DBG5010 User manual

Sealey AK9636D.V2 User manual

Sealey

Sealey AK9636D.V2 User manual

Sealey AK9638D User manual

Sealey

Sealey AK9638D User manual

Sealey TA102 User manual

Sealey

Sealey TA102 User manual

Sealey TA060 User manual

Sealey

Sealey TA060 User manual

Sealey TA500 User manual

Sealey

Sealey TA500 User manual

Sealey Auto Service Line VS0565 User manual

Sealey

Sealey Auto Service Line VS0565 User manual

Sealey DBG509 User manual

Sealey

Sealey DBG509 User manual

Sealey Auto Service Series User manual

Sealey

Sealey Auto Service Series User manual

Sealey AK9636D User manual

Sealey

Sealey AK9636D User manual

Popular Measuring Instrument manuals by other brands

Suaoki D40 user manual

Suaoki

Suaoki D40 user manual

Elster BK-G1.6 operating instructions

Elster

Elster BK-G1.6 operating instructions

Endress+Hauser Deltabar FMD71 technical information

Endress+Hauser

Endress+Hauser Deltabar FMD71 technical information

Duratool D03128 manual

Duratool

Duratool D03128 manual

Vega VEGAPULS 65 Quick setup guide

Vega

Vega VEGAPULS 65 Quick setup guide

Tonghui TH2618B Operation manual

Tonghui

Tonghui TH2618B Operation manual

Tenmars TM-801 user manual

Tenmars

Tenmars TM-801 user manual

MSR 145 user manual

MSR

MSR 145 user manual

TPS WP-82 manual

TPS

TPS WP-82 manual

PCB Piezotronics 003C30 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 003C30 Installation and operating manual

Tenma 72-10465 manual

Tenma

Tenma 72-10465 manual

Endress+Hauser Proline Promag 50 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline Promag 50 Brief operating instructions

Siemens SITRANS F Coriolis FCT030 Function manual

Siemens

Siemens SITRANS F Coriolis FCT030 Function manual

KLINGER CMF V Series instruction manual

KLINGER

KLINGER CMF V Series instruction manual

Keysight M8290A Getting started guide

Keysight

Keysight M8290A Getting started guide

Acterna MS1400 Operation manual

Acterna

Acterna MS1400 Operation manual

R&S ZPH manual

R&S

R&S ZPH manual

Datacolor ColorReader DC10-2 user guide

Datacolor

Datacolor ColorReader DC10-2 user guide

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

01284 757500
01284 703534 sales@sealey.co.uk
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
www.sealey.co.uk
Web
email
NOTE: It is our policy to continually improve products and as such we reserve the right to
alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for
any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on
01284 757525 and leave your full name and address, including postcode.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE
OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS. USE THIS PRODUCT
CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
FAILURE TO DO SO MAY CAUSE DAMAGE OR PERSONAL INJURY, AND WILL INVALIDATE THE
WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
INSTRUCTIONS FOR:
MODEL: TA100
1. SAFETY INSTRUCTIONS
1.1. GENERAL SAFETY
!When using TA100, please observe all normal
safety rules concerning:
Protection against the dangers of electric shock.
Protection of TA100 against misuse.
!Familiarise yourself with the applications,
limitations and hazards of the TA100.
IF IN ANY DOUBT CONSULT A QUALIFIED
AUTO ELECTRICIAN.
!When not in use, store carefully in a safe, dry,
childproof location.
Storage temperature range -10OC to 50OC.
"
WARNING! Potential Shock Hazard:
HT leads produce high voltages. If the leads appear worn
or cracked; replace them. Avoid inadvertently touching the
leads. Turn engine off before connecting or removing the
inductive pickup.
"
WARNING!
The warnings, cautions and instructions discussed in
this instruction manual cannot cover all possible
conditions and situations that may occur. It must be
understood that common sense and caution are
factors which cannot be built into this product, but
must be applied by the operator.
Declaration of Conformity We, the sole UK importer, declare that the product listed below is in
conformity with the following standards and directives.
DIGITAL CLAMP-ON TACHOMETER
Model: TA100
2002/96/EC WEEE Directive
93/68/EEC CE Marking Directive
For Jack Sealey Ltd. Sole UK importer of Sealey Professional Tools.
The construction file for this product is held
by the Manufacturer and may be inspect-
ed, by a national authority, upon request
to Jack Sealey Ltd.
Signed by Tim Thompson 1st June 2007
Thank you for purchasing a Sealey Product. Manufactured to a high standard this product will, if used according to
these instructions and properly maintained, give you years of trouble free performance.
Environmental Protection.
Recycle unwanted materials instead of disposing of them as waste. All tools,
accessories and packaging should be sorted, taken to a recycle centre and
disposed of in a manner which is compatible with the environment.
When the product is no longer required, it must be disposed of in an
environmentally protective way.
DIGITAL CLAMP-ON TACHOMETER
1
4
2. SPECIFICATION
No wires, no cables and no fragile antennae - simply clamps around HT lead. Ideal for setting
engine idle speed. Shows engine speed on large LCD display. Includes hold function. Reads
RPM on DIS/2-stroke and 4-stroke engines. Powered by 9V cell (not included).
4-Stroke: . . . . . . . . . . . . . . . . .600–12000rpm.
DIS/2-Stroke: . . . . . . . . . . . . . .300–6000rpm.
Jaw Opening: . . . . . . . . . . . . .16mm.
Battery: . . . . . . . . . . . . . . . . . .1 x 9V.
Ranges (RPM4): . . . . . . . . . . .600-2000, 2000-12000(x10RPM).
Ranges (RPM2/DIS): . . . . . . . .300-2000, 2000-6000(x10RPM).
Resolution: . . . . . . . . . . . . . . .1RPM.
Effect Reading: . . . . . . . . . . . .>600RPM for RPM4, >300RPM for RPM2/DIS.
Accuracy: . . . . . . . . . . . . . . . .± 2.0% + 5.
Display: . . . . . . . . . . . . . . . . . .1999 counts LCD with battery indication.
Overange Indication: . . . . . . . .‘1’shown on display.
Low Battery Indication: . . . . . .‘ ‘ shown on display.
Measurement Rare: . . . . . . . . .2.5 times per second nominal.
Storage Temperature: . . . . . . .-10°C - 50°C at <80%RH.
Power: . . . . . . . . . . . . . . . . . .Single 9V battery.
SWITCH POSITIONS (FIG.1).
1. ‘OFF’
2. x10 (Stroke (4) RPM): For RPM of 4-stroke engines which have 1 ignition on every 2
revolutions.
3. x1 (Stroke (4) RPM): For RPM of 4-stroke engines which have 1 ignition on every 2
revolutions.
4. x10 (Stroke (2) RPM): For RPM of DIS (Distributor-less Ignition System) and 2 -stroke
engines which have 1 ignition on every 1 revolution.
5. x1 (Stroke (2) RPM): For RPM of DIS (Distributor-less Ignition System) and 2 -stroke
engines which have 1 ignition on every 1 revolution.
6. ‘HOLD’ button.
FIG.1
4.1. Select a suitable RPM range with the function switch (see
switch positions above).
"WARNING! Potential Shock Hazard:
HT leads produce high voltages. If the leads appear worn or
cracked; replace them. Avoid inadvertently touching the
leads. Turn engine off before connecting or removing the
inductive pickup.
4.2. Clamp the inductive pickup over a spark plug HT lead and
start the vehicle, If no reading is observed, stop the vehicle,
unhook the clamp, turn it over and connect again. Re-start
the vehicle and check reading.
Note: Position the pickup to within six inches of the spark plug or
move it to another plug HT lead if no reading or an erratic reading
is obtained.
4.3. If the ‘ ‘ symbol appears, the battery should be replaced.
Remove the screw on the battery cover. Replace the battery
and reinstall the battery cover and screw.
4. OPERATION
3. DESCRIPTION
12 3 4
1. Inductive pickup. RPM measurement for automotive engines up to 8 cylinders.
2. LCD display.
3. Data hold.
a. Press data hold once to hold the current reading.
b. Press the data hold again to exit and resume reading.
4. Power/function/range switch. Turns power on or off and selects measurement
function and range.
HT LEAD
23