logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Sealey
  6. •
  7. Power Tools
  8. •
  9. Sealey AUTO SERVIC VS007.v3 User manual

Sealey AUTO SERVIC VS007.v3 User manual

Other Sealey Power Tools manuals

Sealey POWER TOOLS CP3002 User manual

Sealey

Sealey POWER TOOLS CP3002 User manual

Sealey YK509F.V2 User manual

Sealey

Sealey YK509F.V2 User manual

Sealey CP108VCRWBO User manual

Sealey

Sealey CP108VCRWBO User manual

Sealey AB933 User manual

Sealey

Sealey AB933 User manual

Sealey SG10E User manual

Sealey

Sealey SG10E User manual

Sealey YC10B.V3 User manual

Sealey

Sealey YC10B.V3 User manual

Sealey CP1440MH User manual

Sealey

Sealey CP1440MH User manual

Sealey E5188.V4 User manual

Sealey

Sealey E5188.V4 User manual

Sealey SA660 User manual

Sealey

Sealey SA660 User manual

Sealey SMS2101 User manual

Sealey

Sealey SMS2101 User manual

Sealey YK759F.V3 User manual

Sealey

Sealey YK759F.V3 User manual

Sealey SB973 User manual

Sealey

Sealey SB973 User manual

Sealey CP1209 User manual

Sealey

Sealey CP1209 User manual

Sealey SDL12 User manual

Sealey

Sealey SDL12 User manual

Sealey SV10.8 Series User manual

Sealey

Sealey SV10.8 Series User manual

Sealey BSL100.V2 User manual

Sealey

Sealey BSL100.V2 User manual

Sealey POWER TOOLS SA2004KIT User manual

Sealey

Sealey POWER TOOLS SA2004KIT User manual

Sealey SDL7.V2 User manual

Sealey

Sealey SDL7.V2 User manual

Sealey CP2612 User manual

Sealey

Sealey CP2612 User manual

Sealey VSE200.V3 User manual

Sealey

Sealey VSE200.V3 User manual

Sealey AK2970 User manual

Sealey

Sealey AK2970 User manual

Sealey PPF100S User manual

Sealey

Sealey PPF100S User manual

Sealey CP1202 User manual

Sealey

Sealey CP1202 User manual

Sealey CP72V User manual

Sealey

Sealey CP72V User manual

Popular Power Tools manuals by other brands

AEG OMNI-JS Original instructions

AEG

AEG OMNI-JS Original instructions

SIP 01533 manual

SIP

SIP 01533 manual

Ribimex PRS499 quick start guide

Ribimex

Ribimex PRS499 quick start guide

3M Fiber Optic Connector Crimp Tool instructions

3M

3M Fiber Optic Connector Crimp Tool instructions

Ryobi P524 Operator's manual

Ryobi

Ryobi P524 Operator's manual

ROJEK FSN 300A manual

ROJEK

ROJEK FSN 300A manual

WABCO OptiTire installation manual

WABCO

WABCO OptiTire installation manual

EINHELL TE-MS 18/210 Li Original operating instructions

EINHELL

EINHELL TE-MS 18/210 Li Original operating instructions

Orgapack OR-T 85 Operating and safety instructions

Orgapack

Orgapack OR-T 85 Operating and safety instructions

TOUGHCUT Diamond 400 instruction manual

TOUGHCUT

TOUGHCUT Diamond 400 instruction manual

Yaros PB-3603 user manual

Yaros

Yaros PB-3603 user manual

Fein BSS 2.0 E Repair instructions

Fein

Fein BSS 2.0 E Repair instructions

Baileigh Industrial SS-2725 Operator's manual

Baileigh Industrial

Baileigh Industrial SS-2725 Operator's manual

Milwaukee 2674-20 Operator's manual

Milwaukee

Milwaukee 2674-20 Operator's manual

Fein BLs 1.6 parts list

Fein

Fein BLs 1.6 parts list

Princess Electric Multi Sharpener user manual

Princess

Princess Electric Multi Sharpener user manual

FOREDOM K.1050 Operation & maintenance manual

FOREDOM

FOREDOM K.1050 Operation & maintenance manual

Silca MARKER 2000 operating manual

Silca

Silca MARKER 2000 operating manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

INSTRUCTIONS FOR:
ELECTRONIC STETHOSCOPE KIT, 6
CHANNEL
Model No:VS007.V3
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free
performance.
1. SAFETY INSTRUCTIONS
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT
CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL
INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
Check the content against the list below. If any items are missing or
damaged contact your supplier.
• Stethoscope
• Stethoscope probe
• Headphones
• Microphone Clamps x 6
• Control Box
2. INTRODUCTION
3. CONTENT
Original Language Version VS007.V3 Issue: 1 - 24/03/10
1.1. GENERAL SAFETY
 WARNING! Ensure Health & Safety, local authority, and general
workshop practice regulations are adhered to when using this
equipment.
Familiarise yourself with the application and limitations of the
equipment, as well as the specific potential hazards.
 Maintain the equipment in good condition (use an authorised
service agent).
Replace or repair damaged parts. Use genuine parts only.
Unauthorised parts may be dangerous and will invalidate the
warranty.
Keep the equipment clean for best and safest performance.
Ensure cables, probe and clamps cannot contact moving parts.
 DO NOT place cables, probe or clamps near high voltage items -
HT leads, spark plugs or ignition coil.
 Before road test ensure all cables are secure and, if they
become disconnected, cannot contact moving parts.
When conducting a road test the driver must not operate the
VS007.
 DO NOT allow untrained persons to operate the VS007.
 DO NOT allow children to play with the VS007.
 DO NOT operate the equipment when you are tired or under the
influence of alcohol, drugs or intoxicating medication.
When not in use switch off equipment and store in a safe, dry,
childproof area.
For prolonged storage remove batteries.
Super-sensitive stethoscope, suitable for detection of faults in:
• Engine, Transmission.
• Cat Intake/Exhaust Manifold.
• Fuel Injectors, Radiators.
• Valves, Fuel Tanks.
Kit includes audio probe, headphones, six clip-on microphones and
six-channel microphone selector box. Used by noise, harshness and
vibration engineers to isolate problem sources. Enables vehicle to be
road-tested and diagnosed simultaneously.
4. OPERATION
 WARNING! Ensure you read, understand and apply the safety instructions in Section 1.
 WARNING! Prolonged exposure to high volumes of noise, or sudden very loud noises can result in permanent hearing loss.
 WARNING! Feedback can damage the equipment - keep microphones away from headphones.
4.1. Stethoscope.
4.1.1. Fit PP9 battery into compartment in base of stethoscope.
4.1.2. Confirm that stethoscope is switched off - red indicator LED (fig.1.1) not illuminated.
4.1.3. Plug headphone cable jack into socket (fig.1.2) in base of stethoscope.
4.1.4. Wearing headphones, switch on stethoscope at rotary switch (fig.1.3) - red LED illuminates - and slowly increase volume to a comfortable
level.
4.1.5. Place rubber tip (fig.1.4) on, or near, suspect component. You can also insert the stethoscope probe into the stethoscope rubber tip, this is
useful for detecting noises within casings.
4.2. NVH Tests
4.2.1. Fit PP9 battery into compartment in base of control box.
4.2.2. Install microphone clamp(s) on, or close to, suspect item(s) and/or in reference areas, as required. Pay attention to cable routing and security.
Use cable ties to secure cables.
4.2.3. Plug the clamp cable jacks into the sockets (fig.2.1) in the control box. Note that sockets are numbered and selector scale (fig.2.2) has
corresponding numbers with colour codes to match colour coding on clamp cables, as below:
1 - Blue 3 - Green 5 - Red
2 - Yellow 4 - White 6 - Black
4.2.4. Plug headphone cable jack into socket (fig.2.3) in control box.
4.2.5. Wearing headphones, switch on control box (fig.2.4) - red LED (fig.2.5) illuminates - and slowly increase volume to a comfortable level.
4.2.6. Selector switch (fig.2.6) can now be used to listen to each microphone clamp in turn.
fig. 1 fig. 2
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
01284 757500
01284 703534
sales@sealey.co.uk
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
www.sealey.co.uk
Web
email
Original Language Version VS007.V3 Issue: 1 - 24/03/10
Environmental Protection.
Recycle unwanted materials instead of disposing of them as waste.
All tools, accessories and packaging should be sorted, taken to a recycle centre and disposed of in a manner which is
compatible with the environment.
When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local
solid waste authority for recycling information.
Battery Removal.
Stethoscope: Slide off the rear battery cover and remove the battery.
Control Box: Slide off the rear battery cover and remove the battery.
Dispose of batteries according to local authority guidelines.
Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential
purchasers of products containing batteries (as defined within these regulations), that they are registered with Valpak’s
registered compliance scheme.
Jack Sealey Ltd’s Batteries Producer Registration Number (BPRN) is BPRN00705