Sealey VS904.V2 User manual

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
1.1. General Safety
WARNING! Ensure that Health & Safety, local authority and general workshop practice regulations
are adhered to when using this equipment.
WARNING! DO NOT aim the laser beams at your or another person’s or animal’s eye and beware of
reflections from mirrors or other shiny surfaces.
Familiarise yourself with the applications, limitations, and potential hazards of the thermometer.
Keep the thermometer clean and in good condition.
Protect the thermometer from the following:
Electro-magnetic fields from engine components, arc welders and induction heaters closer than 125mm.
Static electricity.
Thermal shock caused by large and/or rapid ambient temperature change.
High temperatures.
DO NOT get the thermometer wet or use in damp or wet locations or areas where there is condensation.
DO NOT take readings through transparent materials such as glass or clear plastic. The surface
temperature of these materials will be measured.
DO NOT use the thermometer in areas where there is steam, dust or smoke. These conditons will
result in erroneous readings.
DO NOT use the thermometer for any purpose other than that for which it is designed.
DO NOT allow untrained persons (particularly children) to operate the thermometer.
DO NOT operate the thermometer when you are tired or under the influence of alcohol, drugs or
intoxicating medication.
1.2. Laser Safety
The VS904.V2 utilises a Class II laser that emits low levels of visible radiation (i.e. wavelengths between 400 and 700 nanometres)
which are safe for the skin but not inherently safe for the eyes. The Class II emission limit is set at the maximum level for which eye
protection is normally afforded by natural aversion responses to bright light. Accidental eye exposure is therefore normally safe, although
the natural aversion response can be overridden by deliberately staring into the beam, and can also be influenced by the use of alcohol
or drugs.
WARNING!DO NOT look or stare into the laser beam as permanent eye damage could result.
Be aware that reflections of the laser beam from mirrors or other shiny surfaces can be as hazardous as direct eye exposure.
2. INTRODUCTION/SPECIFICATION
2.1. Introduction
High resolution laser thermometer that detects energy emission in the infrared spectrum and converts reading into a display of temperature.
Features laser pointer, data hold function and auto power off. Temperature is displayed on a large 23mm LCD panel with back-lit display for
use in low light areas. Temperature can be shown in either °C or °F. The Digital Thermometer is powered by a 9V cell (supplied).
2.2. Specification
Original Language Version
© Jack Sealey Limited 2012
INSTRUCTIONS FOR: INFRARED LASER
DIGITAL THERMOMETER (12:1)
Model No: VS904.V2
Model No:....................................................................................... VS904.V2
Focal Ratio:...............................................................................................12:1
Temperature Range:.......................................-50 to +550°C (-58 to +1022°F)
Accuracy:(0°C to 550°C)..................................+/- 1.5°C whichever is greater
(-50° to 0°C).................................................................. ....+/- 3°C
Resolution:................................................................................0.1°C or 0.1°F
Repeatability:............................................................................ 1% of reading
Response time:....................................................... 500mSec, 95% response
Spectral response: ............................................................................. 8-14μm
Emissivity:..................................................................................... 0.95 Preset
Operating Temperature: ...........................................0 to +40°C (32 to 104°F)
Operating Humidity:............10 to 95%RH non-condensing up to 30°C (86°F)
Storage Temperature:.......................................... -20 to +60°C (-4 to +140°F)
Power:............................................................................ 9V battery (supplied)
Typical battery life:.................... Non laser mode: 22 hrs; Laser mode: 12 hrs
Weight: .................................................................................................147.5g
Dimensions: .......................................................... 153mm x 101mm x 43mm
ABCD
E
G
F
LCD Display-:
A: Data hold icon
B: Scanning icon
C: Laser "ON" icon
D: Backlight "ON" icon
E: Battery status icon
F: Temperature units (C° or F°)
G: Temperature reading
VS904.V2 Issue: 2(SP) - 22/07/13

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
01284 757500
01284 703534
sales@sealey.co.uk
www.sealey.co.uk
Web
email
Original Language Version
© Jack Sealey Limited 2012
Environmental Protection.
Recycle unwanted materials instead of disposing of them as waste.
All tools, accessories and packaging should be sorted, taken to a recycle centre and disposed of in a manner which is compatible
with the environment.
When the product is no longer required, it must be disposed of in an environmentally protective way.
Contact your local solid waste authority for recycling information.
Open battery compartment as described in Section 3.1. Disconnect battery and remove.
Dispose of batteries according to local authority guidelines.
Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products
containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme.
Jack Sealey Ltd’s Batteries Producer Registration Number (BPRN) is BPRN00705
3. SET UP
3.1. Installing/ChangingBattery(g.1)
3.1.1. On either side of the trigger, where the handle moulding meets the main
body there are two very shallow recesses. Place thumb and finger into
these recesses and pull the front section of the handle forward and down to
reveal the battery compartment.
3.1.2. Attach the battery connector to the battery terminals and place the battery
into the battery compartment making sure that the connection leads will not
foul the cover when it is closed.
3.1.3. When the ‘battery low’ indicator appears on the display replace the battery
immediately, (See Enviromental Protection).
fig.1
4. OPERATION AND APPLICATION
4.1 Depress the trigger (1) in g 3 to switch on the unit, the 'SCAN' icon will
illuminate.
4.2 Decide what units are required by pressing the '°C/°F' button (3) in g 3. The
button will toggle between the specied units.
4.3 Pay attention to the distance from the thermometer to the target as the target
surface size increases with distance. A ratio of 12:1 exists, see g 2.
Make sure the target is larger than the unit's spot size. The smaller the
target, the closer the distance "D". When accuracy is critical ensure the
target is at least twice the spot size.
4.4 The unit is equipped with a laser for the purpose of aiming only. With the
laser button (2) in g 3 in the 'on' or 'off' mode, aim at the target surface and
depress the trigger. The temperature of the target surface will be displayed
on the LCD display screen. When the trigger is released the reading will be
held for 7 seconds approximately; the 'HOLD' icon will be illuminated in this
period; and then the thermometer will automatically shut down unless the
trigger is depressed again.
4.5 To locate a hot spot on a large surface, aim the thermometer as in 4.4,
then scan across the area with a controlled uniform "zig-zag" sweep until you
locate the spot, as illustrated in g 4.
1)Trigger
3) Units
°C/°F
4) Back light
on/off
2) Laser
on/off
fig.2
fig.3
fig.4
5. NOTES ON EMISSIVITY
5.1 Emissivity is a term used for the ability of a surface to radiate energy. This unit has been pre-set with an emissivity of 0.95, which
makes it suitable for 90% of typical applications.
5.2 Inaccurate results will occur when targeting shiny or polished surfaces. As a tip, apply a non reective tape to the area to be tested,
allowing time for the surface temperature of the tape to reach that of the substrate.
6. CLEANING
6.1 The sensor lens is delicate and should be kept clean at all times. Use a cotton bud and medical alcohol, allowing lens to dry. The
casing can be cleaned with a moist cloth and mild soap but never submerged.
Trigger
Depressed
VS904.V2 Issue: 2(SP) - 22/07/13
Table of contents
Other Sealey Thermometer manuals

Sealey
Sealey VS900.V4 User manual

Sealey
Sealey VS905 User manual

Sealey
Sealey VS909 User manual

Sealey
Sealey VS900.V3 User manual

Sealey
Sealey Auto Service Line VS900.V3 User manual

Sealey
Sealey VS904 User manual

Sealey
Sealey VS907 User manual

Sealey
Sealey VS905 User manual

Sealey
Sealey VS940 User manual

Sealey
Sealey Auto Service Line VS904.V2 User manual